MICRODC WRB0505YMT-3W

WRA-YMT-3W&WRB-YMT-3W Series
3W, WIDE INPUT , ISOLA TED & REGULATED SINGLE/DUAL OUTPUTDC/DC CONVERTER
SELECTION GUIDE
Input
Output
Voltage(VDC)
Order code
Voltage
(VDC)
Current(mA)
Efficiency
(%,Typ)
Nominal
Range
Max.*
Max.
Min.
WRA0505YMT-3W
5
4.5-9
11
±5
±300
±30
72
WRA0512YMT-3W
5
4.5-9
11
±12
±125
±13
74
WRA0515YMT-3W
5
4.5-9
11
±15
±100
±10
75
WRB0505YMT-3W
5
4.5-9
11
5
600
60
72
◆Operating temperature: -40℃ ~ +85 ℃
WRB0512YMT-3W
5
4.5-9
11
12
250
25
74
◆1500VDC isolation
WRB0515YMT-3W
5
4.5-9
11
15
200
20
75
WRA1205YMT-3W
12
9-18
22
±5
±300
±30
76
WRA1212YMT-3W
12
9-18
22
±12
±125
±13
79
◆Internal SMD construction
WRA1215YMT-3W
12
9-18
22
±15
±100
±10
79
◆MTBF>1,000,000 hours
WRB1205YMT-3W
12
9-18
22
5
600
60
74
WRB1212YMT-3W
12
9-18
22
12
250
25
79
FEATURES
◆2:1 Wide input voltage range
◆No heatsink required
◆Short circuit protection(automatic recovery)
WRB1215YMT-3W
12
9-18
22
15
200
20
79
◆Industry standard pinout
WRA2405YMT-3W
24
18-36
40
±5
±300
±30
76
◆RoHS Compliance
WRA2412YMT-3W
24
18-36
40
±12
±125
±13
79
WRA2415YMT-3W
24
18-36
40
±15
±100
±10
79
WRB2405YMT-3W
24
18-36
40
5
600
60
76
WRB2412YMT-3W
24
18-36
40
12
250
25
79
WRB2415YMT-3W
24
18-36
40
15
200
20
79
WRA4805YMT-3W
48
36-72
80
±5
±300
±30
76
WRA4812YMT-3W
48
36-72
80
±12
±125
±13
79
WRA4815YMT-3W
48
36-72
80
±15
±100
±10
79
WRB4805YMT-3W
48
36-72
80
5
600
60
76
WRB4812YMT-3W
48
36-72
80
12
250
25
79
WRB4815YMT-3W
48
36-72
80
15
200
20
79
MODEL SELECTION
①
②
③ ④
⑤
⑥
WRB 24 12 Y MT -3W
①Product Series
③Output Voltage
⑤Mini package style
②Input Voltage
④Wide (2:1) Input Range
⑥Rated Power
*Input voltage can ' t exceed this value, or will cause the permanent damage.
APPLICATIONS
The
WRA_YMT-3W&WRB_YMT-3W
series
are
specially designed for applications where a wide range
input voltage power supplies are isolated from the
input power supply in a distributed power supply system
on a circuit board.
These products apply to:
COMMON SPECIFICATIONS
1) Where the voltage of the input power supply is wide
Parameter
range(voltage range ≤2:1);
Test conditions
Min.
2) Where isolation is necessary between input and
Storage humidity
output (isolation voltage ≤1500VDC);
Operating temperature
-40
Storage temperature
-55
3) Where the regulation of the output voltage and the
output ripple noise are demanded.
Temp. rise at full load
Lead temperature
Max.
1.5mm from case for 10 seconds
%
85
℃
125
℃
℃
℃
300
Continuous, automatic recovery
Cooling
Free air convection
Package material
Epoxy Resin (UL94-V0)
1000
Weight
K hours
5.2
MICRODC reserves the copyright
http://www.microdc.cn
Units
95
15
Short circuit protection
MTBF
Typ.
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 1 of 3
g
WRA-YMT-3W&WRB-YMT-3W Series
ISOLATION SPECIFICATIONS
Parameter
TYPICAL CHARECTERISTICS
Test conditions
Min.
Isolation voltage
Tested for 1 minute and 1mA max
1500
Isolation resistance
Test at 500VDC
1000
Isolation capacitance
Input/output, 100KHz/1V
Typ.
Max
Units
VDC
MΩ
1000
pF
OUTPUT SPECIFICATIONS
Parameter
Test conditions
Min.
Typ.
Max
Units
3
W
±3
%
±3
±5
%
±0.5
±1*
%
Output power
See above products program
0.3
Positive voltage accuracy
Refer to recommended circuit
Negative voltage accuracy
Refer to recommended circuit
Load regulation
From 10% to 100% load
Line regulation
Input voltage from low to high
±0.2
±0.5
%
Temperature Drift (Vout)
Refer to recommended circuit
±0.03
%/℃
Output ripple& noise**
20MHz Bandwidth
35
100
mVp-p
Switching frequency
100% load, nominal input voltage
300
±1
KHz
* Dual output models unbalanced load:±5%.
**Test ripple and noise by “parallel cable”method. See detailed operation instructions at Testing of Power
Converter section, application notes.
RECOMMENDED CIRCUIT
APPLICATION NOTE
Requirement on output load
In order to ensure the product operate efficiently and reliably, in addition to a max load (namely full
load), a minimum load is specified for this kind of DC/DC converter. Make sure the specified range of
input voltage is not exceeded, the minimum output load no less than 10% load. If the actual load is less
than the specified minimum load, the output ripple may increase sharply while its efficiency and reliability
will reduce greatly. If the actual output power is very small, please add an appropriate resistor as extra
loading, or contact our company for other lower output power products.
Recommended Circuit
All the WRA_YMT-3W & WRB_YMT-3W series have been tested according to the following
recommended testing circuit before leaving factory. This series should be tested under load (See Figure 1).
If you want to further decrease the input/output ripple, you can increase capacitance properly or choose
capacitors with low ESR. However, the capacitance of the output filter capacitor must be proper. If the
capacitance is too big, a startup problem might arise. For every channel of output, provided the safe and
reliable operation is ensured, the greatest capacitance of its filter capacitor sees (Table 1).
General:
Cin:
5V&12V
24V&48V
100µF
10µF~47µF
Cout: 10µF/100mA
Input Current
When it is used in unregulated power supply, be sure that the fluctuating range of the power supply and
the rippled voltage do not exceed the module standard. Input current of power supply should afford the
flash startup current of this kind of DC/DC module (Figure 2),
General: Ip ≤1.6*Iin-max(Vin=5V)
Ip ≤1.4*Iin-max(Vin=12V/24V/48V)
No parallel connection or plug and play
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 2 of 3
WRA-YMT-3W&WRB-YMT-3W Series
OUTLINE DIMENSIONS & FOOTPRINT DETAILS
MECHANICAL DIMENSIONS
RECOMMENDED FOOTPRINT(TOP VIEW)
TUBE OUTLINE DIMENSIONS
Note:
1. The load shouldn't be less than 10%, otherwise ripple will increase dramatically.
2.
Operation under 10% load will not damage the converter; However, they may not meet all specification listed.
3.
Capacitor MAX load tested at input voltage range and full load.
4. All specifications measured at Ta=25℃, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
5.
Only typical models listed, other models may be different, please contact our technical person for more details.
6.
In this datasheet, all the test methods of indications are based on corporate standards.
RoHS COMPLIANT INFORMATION
Microdc Professional Power Module,Inc.
This series is compatible with RoHS soldering systems with a peak wave solder temperature of 300°C
Tel:0086-20-86000646 E-mail:[email protected]
for 10 seconds. The pin termination finish on the SIP package type is Tin Plate, Hot Dipped over Matte
Website:http://www.microdc.cn
Tin with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both types in this series are
Microdc Professional Power module,Inc.makes no representation that
backward compatible with Sn/Pb soldering systems.
the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or
REACH COMPLIANT INFORMATION
future patent rights. Specifications are subject to change without notice.
This series has proven that this product does not contain harmful chemicals, it also has harmful chemical
©2010
substances through the registration, inspection and approval.
Microdc Professional Power Module, Inc. Guangzhou
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 3 of 3