FERROXCUBE E35-3C90-A400

FERROXCUBE
DATA SHEET
E35/18/10
E cores and accessories
Supersedes data of September 2004
2008 Sep 01
Ferroxcube
E cores and accessories
E35/18/10
CORE SETS
Effective core parameters
SYMBOL
PARAMETER
VALUE
Σ(I/A)
core factor (C1)
0.807
mm−1
Ve
effective volume
8070
mm3
Ie
effective length
80.7
mm
Ae
effective area
100
mm2
Amin
minimum area
100
mm2
m
mass of core half
≈ 20
g
35 ±0.5
handbook, halfpage
UNIT
24.5 min.
10 ±0.3
handbook, halfpage
12.5
±0.25
17.5
±0.25
R1
10 ±0.3
CBW559
Dimensions in mm.
Fig.1 E35/18/10 core half.
Core halves
AL measured in combination with a non-gapped core half, clamping force for AL measurements, 30 ±15 N, unless stated
otherwise.
GRADE
3C90
3C95
AL
(nH)
TOTAL AIR GAP
(µm)
µe
TYPE NUMBER
100 ±5%(1)
≈ 64
≈ 2000
E35/18/10-3C90-E100
160 ±5%(1)
≈ 103
≈ 1060
E35/18/10-3C90-E160
250 ±5%
≈ 161
≈ 590
E35/18/10-3C90-A250
315 ±5%
≈ 202
≈ 440
E35/18/10-3C90-A315
400 ±8%
≈ 257
≈ 330
E35/18/10-3C90-A400
630 ±15%
≈ 405
≈ 180
E35/18/10-3C90-A630
2500 ±25%
≈ 1610
≈0
E35/18/10-3C90
2980 ±25%
≈ 1915
≈0
E35/18/10-3C95
Note
1. Measured in combination with an equal gapped core half, clamping force for AL measurements, 30 ±15 N.
Properties of core sets under power conditions
B (mT) at
CORE LOSS (W) at
H = 250 A/m;
f = 25 kHz;
T = 100 °C
f = 25 kHz;
ˆ = 200 mT;
B
T = 100 °C
f = 100 kHz;
ˆ = 100 mT;
B
T = 100 °C
f = 100 kHz;
ˆ = 200 mT;
B
T = 25 °C
f = 100 kHz;
ˆ = 200 mT;
B
T = 100 °C
3C90
≥330
≤ 0.95
≤ 1.1
−
−
3C95
≥330
−
−
≤ 4.76
≤ 4.52
GRADE
2008 Sep 01
395
Ferroxcube
E cores and accessories
E35/18/10
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
396