RLY260 Series Features • • • • • • • 30 Amp/2 HP Load Ratings No Heat Sink Required 0.5% Repeat Accuracy .250” Quick Connect Terminals Transient Protected CMOS Digital Timing 2 x 3 Plastic Package Knob Adjustable, AC or DC, Delay On Operate, Electromechanical, High Power Cube Timer. D77 T3 N.C. N.O. COM .250 (6.35) Dia 3.000 (76.2) 0 10 TIME DELAY ADJUSTMENT 1.000 (25.4) 2.000 (50.8) OPERATION DELAY ON OPERATE− The delay period begins when input voltage is applied. At the end of the delay period, the relay will operate and will not release until input voltage is removed. Reset occurs when input voltage is reapplied. 1.200 (30.48) 1.000 (25.4) 1.500 (38.1) Max ON LINE OFF ON LOAD Ratings and Specifications DELAY OFF Input Operating Voltage Range (Line): ±20% AC Operating Frequency: 50/60Hz Switch Configuration: Electromechanical, SPST Switching Current (Load): 500 mA min., 30 Amps max. Switching Current (Load): (Note: U.L. for 20 Amp Only) Repeat Accuracy: ±0.5% Reset Time: 150ms Min. Expected Life: Mechanical: 10,000,000 operations Electrical: 10,000 operations @ rated load Operating Temperature: −40° to +80°C Storage Temperature: −50° to +85°C Dielectric Breakdown Voltage Between All Elements: 1500Vrms Transient Protection: 1500 V for 150µs Mounting: One #8 or #10 Screw N.C. N.O. T3 − Input Power + COM Timer AC OPERATED Timing Adj. Range Nom Voltage Contact Arr. Max. Contact Cur. @ 120VAC Diag No. RLY265L 3 to 100 sec. 120VAC SPST 30A* D77 RLY265N 0.3 to 10 min. 120VAC SPST 30A* D77 RLY261L 3 to 100 sec. 12VDC SPST 30A* D77 RLY261N 0.3 to 10 min. 12VDC SPST 30A* D77 NTE Type No. DC OPERATED * Note: U.L. for 20 Amp Only. 92 NTE Electronics, Inc. Voice (973) 748−5089 FAX (973) 748−6224 http://www.nteinc.com