RLY230 Features • • • • • • • 2 x 2 Industry Standard Package 95−145 Volts AC Operation 1 to 1023 Seconds Timing Range 0.1% Repeat Accuracy Transient Protected .250” Quick Connect Terminals Encapsulated Construction Binary Switch, Programmable, AC, Delay on Operate, Solid State, Universal Cube Timer. D68 .250 (6.35) Dia 2.000 (50.8) 1 INPUT LOAD 3 2.000 (50.8) .250 (6.35) OPERATION DELAY ON OPERATE− The delay period begins when input voltage is applied. At the end of the delay period, the relay will operate and will not release until input voltage is removed. Reset occurs when input voltage is reapplied. Delay Setting ON Combine “ON” switches to set time delay 1 2 4 8 16 32 64 128 256 512 LINE OFF ON ON LOAD DELAY OFF OFF Line N.O. 1 Ex. 329 Seconds. Ratings and Specifications Timer 3 1.0 Amp Max. * LOAD * For higher current applications connect a switching relay in series with timer in place of load. 90 1.200 (30.48) .750 (19.05) NTE Electronics, Inc. Operating Voltage Range (Line): 95−145 V AC (50/60Hz) Switch Configuration: Solid State, SPST Switching Current (Load): 20mA Amp min., 1 Amp max. Timing Adjustment Range: 1 to 1023 seconds Repeat Accuracy: ±0.1% Reset Time: 50ms Max. Expected Life (Electrical): 100,000,000 operations @ rated load Operating Temperature: −20° to +80°C Storage Temperature: −30° to +85°C Dielectric Breakdown Voltage Between All Elements: 1500Vrms Transient Protection: 1500 V for 150µs Mounting: One #8 or #10 Screw Voice (973) 748−5089 FAX (973) 748−6224 http://www.nteinc.com