RLY220 - NTE Electronics

Features
•
•
•
•
•
•
•
2 x 2 Industry Standard Package
18−264 Volts AC or DC Operation
0.2 to 8 Minutes (12 to 480 Seconds) Timing Range
0.5% Repeat Accuracy
Transient Protected
.250” Quick Connect Terminals
Encapsulated Construction
RLY220
Knob Adjustable, AC or DC,
Delay on Operate, Solid State,
Universal Cube Timer.
D67
.250
(6.35)
Dia
2.000
(50.8)
.2
8
MINUTES
1
J1
INPUT
LOAD
3
JUMPER:
SEE
NOTE
2.000 (50.8)
OPERATION
.250 (6.35)
DELAY ON OPERATE− The delay period begins when input voltage
is applied. At the end of the delay period, the relay will operate and
will not release until input voltage is removed. Reset occurs when
input voltage is reapplied.
.750
(19.05)
1.200
(30.48)
ON
LINE
OFF
NOTE: 18−40 V AC or DC
Cut J1 for 40−264 V AC, DC
ON
LOAD
DELAY
OFF
Ratings and Specifications
Line
Timer
1.0 Amp
Max. *
1
3
LOAD
* For higher current applications connect a switching relay in series with
timer in place of load.
NTE Electronics, Inc.
Voice (973) 748−5089
Operating Voltage Range (Line):
Jumper J1 Not Cut: 18−40 V DC or AC (50/60Hz)
Jumper J1 Cut: 40−264 V DC or AC (50/60Hz)
Switch Configuration: Solid State, SPST
Switching Current (Load): 40mA Amp min., 1 Amp max.
Timing Adjustment Range: 0.2 to 8 minutes (12 to 480 seconds)
Repeat Accuracy: ±0.5%
Reset Time: 100ms Max.
Expected Life (Electrical): 100,000,000 operations @ rated load
Operating Temperature: −20° to +80°C
Storage Temperature: −40° to +85°C
Dielectric Breakdown Voltage Between All Elements: 1500Vrms
Transient Protection: 1500 V for 150µs
Mounting: One #8 or #10 Screw
FAX (973) 748−6224
http://www.nteinc.com
89