Constant voltage LED Drivers For indoor use LSU-16V Series, 16Watt FEATURES: Constant voltage output Cooling by free air convection Short circuit, over voltage protections IP30 rating Class Ⅱ, no FG 100% burn-in test 2 year warranty Model LSU16-V5 LSU16-V12 LSU16-V15 LSU16-V24 Input voltage (Vac) 90-264 Output voltage (Vdc) Output current (mA) Output power (W) Min. Max. 5 0 2600 13 12 0 1250 15 15 0 1000 15 24 0 670 16 ELECTRICAL Input Parameters Symbols Test Conditions / Comment Input voltage Vin -- Input frequency Fline Input current Min. Typ. Max. Units 90 -- 264 Vac 120 -- 370 Vdc -- 47 -- 63 Hz Full load, Vin =115Vac -- 0.35 A Full load, Vin =230Vac -- 0.2 A Iin Inrush current Iinrush Cold start, Vin =230Vac -- 75 -- A Leakage current Ileakage Vin =240Vac -- 0.25 -- mA η Full voltage, full load -- 90 -- % Efficiency www.pairuigroup.com Page: 1 / 4 Date: 07/17/2015 Constant voltage LED Drivers For indoor use LSU-16V Series, 16Watt ELECTRICAL Output Parameters Test Conditions / Comment Min. Typ. Max. Units LSU16-V5 0 -- 2600 mA LSU16-V12 0 -- 1250 mA LSU16-V15 0 -- 1000 mA LSU16-V24 0 -- 670 mA LSU16-V5 4.75 5 5.25 V LSU16-V12 11.4 12 12.6 V LSU16-V15 14.25 15 15.75 V LSU16-V24 22.8 24 25.2 V -- -- -- ±5.0 -- % Line regulation Iout-line -- -- ±1.0 -- % Load regulation Iout-load -- -- ±2.0 -- % Full load, Vin =115Vac -- -- mS Full load, Vin =230Vac -- -- mS LSU16-V5 -- -- 100 mVp-p LSU16-V12 -- -- 120 mVp-p LSU16-V15 -- -- 120 mVp-p LSU16-V24 -- -- 150 mVp-p Output current Output voltage Output voltage accuracy Turn-on, rise time Ripple Symbols Iout Vout -- Vripple 1500, 30 1500, 30 Protection Over load Short circuit >105% rated output power Hiccup mode, it will recover automatically after fault condition is removed Hiccup mode, it will recover automatically after fault conditions is removed Environment Storage Ambient operating temperature Operating relative humidity www.pairuigroup.com Tstorage Ta Ha Humidity: 10% RH to 95% RH Startup at rated voltage (required Derating) Non condensing Page: 2 / 4 -40 -- +80 ℃ -30 -- +70 ℃ 20 -- 90 % Date: 07/17/2015 Constant voltage LED Drivers For indoor use LSU-16V Series, 16Watt ELECTRICAL Environment Parameters MTBF Temperature coefficient Symbols TMTBF Test Conditions / Comment Full load, 220Vac input, ℃ ambient temperature 25 0~50 -- Min. Typ. Max. Units 400 -- -- kHrs -- ±0.2 -- % ℃ Dimension(LxWxH) 77 x 40 x 29mm Safety / EMC Safety standards EN61347-1, EN61347-2-13 EMC EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11, EN61547 ℃ Notes: 1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 and Vin = 230Vac, rated load; 2. Ripple & Noise are measured at 20MHZ of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor. MECHANICAL Unit: mm www.pairuigroup.com Page: 3 / 4 Date: 07/17/2015 Constant voltage LED Drivers For indoor use LSU-16V Series, 16Watt ELECTRICAL CURVE DERATING CURVE www.pairuigroup.com STATIC CHARACTERISTICS Page: 4 / 4 Date: 07/17/2015