Model
DMV20W-2411
DMV20W-2412
DMV20W-2413
DMV20W-2414
DMV20W-2415
DMV20W-2416
DMV20W-2421
DMV20W-2422
DMV20W-2423
DMV20W-2424
DMV20W-2425
DMV20W-4811
DMV20W-4812
DMV20W-4813
DMV20W-4814
DMV20W-4815
DMV20W-4816
DMV20W-4821
DMV20W-4822
DMV20W-4823
DMV20W-4824
DMV20W-4825
Input voltage
(Vdc)
24(9~36)
48(18~72)
Output voltage
(Vdc)
Output current
(mA)
Efficiency
Typ.
5
4000
80%
9
2220
85%
12
1660
85%
15
1330
85%
24
830
85%
48
410
85%
±5
±2000
80%
±9
±1110
85%
±12
±830
85%
±15
±660
85%
±24
±410
85%
5
4000
80%
9
2220
85%
12
1660
85%
15
1330
85%
24
830
85%
48
410
85%
±5
±2000
80%
±9
±1110
85%
±12
±830
85%
±15
±660
85%
±24
±410
85%
Notes:
1. Other input and output models may available on request;
2. Above models are default to metal case.
www.pairuigroup.com
Page:
1/4
Date: 07/24/2015
*Subject to change without notice
DC-DC Converter
DIP-Package
DMV-20W SERIES, 20WATT, 4:1 INPUT RANGE
ELECTRICAL
Input voltage range
18V
9-36Vdc
36V
18-72Vdc
Remote control
High level or vacant
Turn on
(Low level remote)
Low level or connect ground
Turn off
Output voltage accuracy
---
Vo1, Vo2: ±1%, ±3%
Output voltage adjustable
---
±10%
Line regulation
Nominal Load, full voltage
Load regulation
20% ~ 100% rated load
Vo1, Vo2: ±0.5%, ±4%
5%-50%-75% load capability
∆Vo1/∆t: ±4.0%/500μs
Dynamic response
(transient/recovery time)
Vo1, Vo2: ±0.2%, ±1.5%
Vo≤5.0V, ≤50mVp-p
Ripple and noise
20MHz BM, full load
Vo≥48V, ≤180mVp-p
Other, ≤100mVp-p
Isolation voltage
Input to output
(<2mA/min)
Input to case
Switching frequency
300KHz
Turn-on delay time
---
Operating temperature range
Free air
Storage temperature range
---
Input under voltage protection
1500Vdc
500Vdc
330KHz max.
≤200ms
-25℃ to +55℃
-45℃ to +105℃
When input voltage is lower than the
low input voltage
Auto-recovery
Over current protection
---
Auto-recovery
Short circuit protection
---
Continuous auto-recovery
Cooling method
---
Cooling by air convection
Relative humidity
---
10%-90% max.
Weight
---
35.7g
MTBF
Bellcore TR-332, 25℃
2x105Hrs
Notes: Unless otherwise specified, all the parameters of the test conditions are as follows: ambient temperature
25 , the nominal input voltage, pure resistive nominal load.
℃
www.pairuigroup.com
Page:
2/4
Date: 07/24/2015
*Subject to change without notice
DC-DC Converter
DIP-Package
DMV-20W SERIES, 20WATT, 4:1 INPUT RANGE
MECHANICAL
CONNECTION
PIN #
SINGLE
DUAL
1
REM
REM
2
-Vin
-Vin
3
+Vin
+Vin
4
No pin
+Vo1
5
+Vo
COM
6
GND
-Vo2
7
TRIM
TRIM
Note:
* Unit is mm(inch).
LAYOUT
ELECTRICAL CURVE
www.pairuigroup.com
Page:
3/4
Date: 07/24/2015
*Subject to change without notice
DC-DC Converter
DIP-Package
DMV-20W SERIES, 20WATT, 4:1 INPUT RANGE
NOTES
RECOMMENDED TEST AND APPLICATION CIRCUIT
1. TVS&FUSE be helpful with over voltage protection and inrush limiting. Recommended FUSE better be 1.5~2times of
the rated current .
2. The input filter capacitor C6 could select the aluminum electrolytic capacitors or tantalum capacitors, and the
withstand voltage should be greater than the highest input voltage. Recommended capacitor should be between
22μF~100μF.
3. C1,C2 for the input filter capacitor,0.1~1μF high-frequency ceramics capacitor or chip capacitor are recommended.
The withstand voltage of output filter C5, C7 should be greater than the highest output voltage. Recommended
capacitor of C7 better within 100μF and C5 connected with the chip to reduce the input voltage peak, recommended
0.1~1μF high-frequency ceramics capacitor or chip capacitor.