Constant current LED Drivers For outdoor use LFU-60C Series, 60Watt FEATURES: Constant current output Universal AC input range Active power factor correction Short circuit, and over voltage protections Designed to worldwide safety standards for lighting Cooling by free air convection Class , no FG 100% burn-in test 2 year warranty Ⅱ Model Input voltage (Vac) Output voltage (Vdc) Output current (mA) Min. Max. Output power (W) LFU60-C350 350 103 171 59.8 LFU60-C700 700 52 86 60.2 LFU60-C1050 1050 35 57 59.8 1300 29 48 62.4 LFU60-C1400 1400 26 43 60.2 LFU60-C2100 2100 18 29 60.9 LFU60-C2800 2800 13 21 58.8 LFU60-C1300 90-264 ELECTRICAL Input Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Input voltage Vin -- 90 -- 264 Vac Input frequency Fline -- 47 -- 63 Hz Input current Iin Full load, Vin =230Vac -- -- 0.36 A Inrush current Iinrush Cold start, Vin =230Vac -- -- 35 A Power factor PF 70%~100% load, Vin =230Vac -- 0.9 -- PF η Full voltage, full load -- 85 -- % Ton_delay Cold start, power on -- -- 2 S Efficiency Turn-on delay time www.pairuigroup.com Page: 1 / 4 Date: 07/17/2015 Constant current LED Drivers For outdoor use LFU-60C Series, 60Watt ELECTRICAL Output Parameters Output current Output voltage No Load Output Voltage Symbols Iout Vout VNO-Load Test Conditions / Comment Min. Typ. Max. Units LFU60-C350 332 350 368 mA LFU60-C700 665 700 735 mA LFU60-C1050 998 1050 1102 mA LFU60-C1300 1235 1300 1365 mA LFU60-C1400 1330 1400 1470 mA LFU60-C2100 1995 2100 2205 mA LFU60-C2800 2660 2800 2940 mA LFU60-C350 103 -- 171 V LFU60-C700 52 -- 86 V LFU60-C1050 35 -- 57 V LFU60-C1300 29 -- 48 V LFU60-C1400 26 -- 43 V LFU60-C2100 18 -- 29 V LFU60-C2800 13 -- 21 V LFU60-C350 -- -- 205 V LFU60-C700 -- -- 103 V LFU60-C1050 -- -- 68 V LFU60-C1300 -- -- 58 V LFU60-C1400 -- -- 51 V LFU60-C2100 -- -- 35 V LFU60-C2800 -- -- 25 V Line regulation Iout-line Vin from 90Vac to 264Vac -- -- 3 % Load regulation Iout-load Vout from min. To max. -- -- 3 % Iovershoot Turning Power ON -- -- 10 % Iripple --- -- 40%Io -- mAp-p -- Vin =115Vac, output load≥50% -- -- 20 % Output Current Overshoot Ripple THD www.pairuigroup.com Page: 2 / 4 Date: 07/17/2015 Constant current LED Drivers For outdoor use LFU-60C Series, 60Watt ELECTRICAL Protection Parameters Symbols Test Conditions / Comment Min. Typ. Overvoltage 120% typical of max. output voltage Short circuit Hiccup mode, it will recover automatically after fault condition is removed Max. Units Environment Storage Ambient operating temperature Maximum case temperature Operating relative humidity MTBF Tstorage Humidity: 5% RH to 95% RH -40 -- +85 ℃ Ta Startup at rated voltage -25 -- +70 ℃ Tc Hot-spot on case -- -- +80 ℃ Ha Non condensing 10 -- 95 % 400 -- -- kHrs TMTBF Full load, 220Vac input, ℃ 25 ambient temperature Dimension(LxWxH) 162.5 x 42.0 x 32.0mm Safety / EMC Safety standards UL8750, EN61347-1, EN61347-2-13 EMC EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11, EN61547 ℃ Notes: 1.Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 and Vin = 230Vac, rated load. 2.Ripple & Noise are measured at 20MHZ of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor; MECHANICAL Unit: mm www.pairuigroup.com Page: 3 / 4 Date: 07/17/2015 Constant current LED Drivers For outdoor use LFU-60C Series, 60Watt MECHANICAL RECOMMEND INSTALLATION BLOCK DIAGRAM ELECTRICAL CURVE DERATING CURVE www.pairuigroup.com STATIC CHARACTERISTIC CURVE Page: 4 / 4 Date: 07/17/2015