F:\\\271\346\270\361\312\351\\00 LED driver\\LG Series

Constant current LED Drivers
For outdoor use
LGU-200C Series, 200 Watt
FEATURES:
Constant current output
Universal AC input: 90-305VAC
Active power factor correction
Short circuit, over voltage, over temperature protections
Designed to worldwide safety standards for lighting
Cooling by free air convection
5 year warranty
Model
Nominal
Input voltage
(Vac)
Output current
(mA)
Output voltage
(Vdc)
Output power
(W)
Min.
Max.
LGU200-C450
450
267
444
199.8
LGU200-C700
700
171
286
200
LGU200-C1050
1050
114
190
199.5
LGU200-C1400
1400
86
143
200
LGU200-C1750
1750
69
114
199.5
2100
57
95
199.5
2450
49
82
201
LGU200-C2800
2800
43
71
198.8
LGU200-C3150
3150
38
63
198
LGU200-C3500
3500
34
57
199.5
LGU200-C4200
4200
29
48
201
LGU200-C5200
5200
23
38
201
LGU200-C2100
LGU200-C2450
100-277
Note: 1. Add suffix for dimming option, “D” (0~10V), “P” (PWM), “T” (Timer);
2. Add suffix for package option, blank(default), “W” or “L”. See mechanical specifications.
ELECTRICAL
Input
Parameters
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Input voltage
Vin
--
90
--
305
Vac
Input frequency
Fline
--
47
--
63
Hz
Input current
Iin
Full load, Vin = 230Vac
--
1.0
--
A
Inrush current
Iinrush
Cold start, Vin = 230Vac
--
65
--
A
www.pairuigroup.com
Page: 1 / 5
Date: 09/23/2014
Constant current LED Drivers
For outdoor use
LGU-200C Series, 200 Watt
ELECTRICAL
Input
Parameters
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Power factor
PF
70%~100% load, Vin = 230Vac
--
0.96
--
PF
η
Full voltage, full load
--
90
--
%
--
--
5
--
%
LGU200-C450
--
--
491
V
LGU200-C700
--
--
315
V
LGU200-C1050
--
--
210
V
LGU200-C1400
--
--
158
V
LGU200-C1750
--
--
126
V
LGU200-C2100
--
--
111
V
LGU200-C2450
--
--
95
V
LGU200-C2800
--
--
82
V
LGU200-C3150
--
--
74
V
LGU200-C3500
--
--
66
V
LGU200-C4200
--
--
55
V
LGU200-C5200
--
--
42
V
Efficiency
Output
Output current accuracy
No load out voltage
--
VNO-Load
Line regulation
Iout-line
Vin from 90Vac to 305Vac
--
--
1
%
Load regulation
Iout-load
Vout from min. to max.
--
--
3
%
Iover-shoot
Turning power on
--
--
10
%
Ton_delay
Cold start, power on
--
--
2
S
--
--
--
20
--
%
Output Current
overshoot
Turn-on delay time
Ripple
www.pairuigroup.com
Page: 2 / 5
Date: 09/23/2014
Constant current LED Drivers
For outdoor use
LGU-200C Series, 200 Watt
ELECTRICAL
Protection
Parameters
Over voltage
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
115~150% rated output voltage. In latch mode, the power supply shall return to normal
operation only after the power is turned on again
Short circuit
In hiccup mode, it will recover automatically after fault condition is removed
Over temperature
Typ. 110
℃
Environment
Storage
Ambient operating
temperature
Maximum case
temperature
Operating relative
humidity
MTBF
Tstorage
Humidity: 5% RH to 95% RH
-40
--
+85
℃
Ta
Startup at rated voltage
-40
--
+70
℃
Tc
Hot-spot on case
--
--
+80
℃
Ha
Non condensing
10
--
95
%
--
400
--
kHrs
TMTBF
Dimension(LxWxH)
Full load, 220Vac input,
℃
25
ambient temperature
L: 188.5x78.5x37mm/W: 184.5x87x39.5mm
Weight
L: 850g / W: 1000g
Safety / EMC
Safety standards
EMC
UL8750, UL935, UL1012, UL1310 CLASS 2, EN61347-1, EN61347-2-13
EN55015, FCC Part 15 Class B, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11,
EN61547
Notes: Unless otherwise specified, all the above parameters are measured at ambient temperature of 25
Vin = 100Vac to 277Vac.
www.pairuigroup.com
Page: 3 / 5
℃
and
Date: 09/23/2014
Constant current LED Drivers
For outdoor use
LGU-200C Series, 200 Watt
MECHANICAL
PACKAGE TYPE “L”
Unit: mm
PACKAGE TYPE “W”
Unit: mm
www.pairuigroup.com
Page: 4 / 5
Date: 09/23/2014
Constant current LED Drivers
For outdoor use
LGU-200C Series, 200 Watt
DERATING CURVE
www.pairuigroup.com
STATIC CHARACTERISTIC CURVE
Page: 5 / 5
Date: 09/23/2014