F:\\\271\346\270\361\312\351\\00 LED driver\\LG Series

Constant current LED Drivers
For outdoor use
LGU-150C Series, 150 Watt
FEATURES:
Constant current output
Universal AC input: 90-305VAC
Active power factor correction
Short circuit, over voltage, over temperature protections
Designed to worldwide safety standards for lighting
Cooling by free air convection
5 year warranty
Model
Nominal
Input voltage
(Vac)
Output voltage
(Vdc)
Output current
(mA)
Min.
Output power
(W)
Max.
350
257
429
LGU150-C350
450
200
333
LGU150-C450
700
129
214
LGU150-C700
1050
86
143
LGU150-C1050
1400
64
107
LGU150-C1400
100-277
2100
43
71
LGU150-C2100
2800
32
54
LGU150-C2800
3150
29
48
LGU150-C3150
3500
26
43
LGU150-C3500
4200
22
36
LGU150-C4200
Note: 1. Add suffix for dimming option, “D” (0~10V), “P” (PWM), “T” (Timer);
2. Add suffix for package option, blank(default), “W” or “L”. See mechanical specifications.
150
150
150
150
150
150
151
151
150
151
ELECTRICAL
Input
Parameters
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Input voltage
Vin
--
90
--
305
Vac
Input frequency
Fline
--
47
--
63
Hz
Input current
Iin
Full load, Vin = 230Vac
--
0.75
--
A
Inrush current
Iinrush
Cold start, Vin = 230Vac
--
65
--
A
Power factor
PF
70%~100% load, Vin = 230Vac
--
0.96
--
PF
η
Full voltage, full load
--
90
--
%
Efficiency
www.pairuigroup.com
Page: 1 / 4
Date: 08/28/2014
Constant current LED Drivers
For outdoor use
LGU-150C Series, 150 Watt
ELECTRICAL
Output
Parameters
Output current accuracy
No load out voltage
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
--
--
--
5
--
%
LGU150-C350
--
--
469
V
LGU150-C450
--
--
365
V
LGU150-C700
--
--
235
V
LGU150-C1050
--
--
157
V
LGU150-C1400
--
--
117
V
LGU150-C2100
--
--
82
V
LGU150-C2800
--
--
61
V
LGU150-C3150
--
--
55
V
LGU150-C3500
--
--
50
V
LGU150-C4200
--
--
42
V
VNO-Load
Line regulation
Iout-line
Vin from 90Vac to 277Vac
--
--
1
%
Load regulation
Iout-load
Vout from min. to max.
--
--
3
%
Iover-shoot
Turning power on
--
--
10
%
Ton_delay
Cold start, power on
--
--
2
S
--
--
--
20
--
%
Output Current
overshoot
Turn-on delay time
Ripple
Protection
Over voltage
115~150% rated output voltage. In latch mode, the power supply shall return to normal
operation only after the power is turned on again.
Short circuit
In hiccup mode, it will recover automatically after fault condition is removed.
Over temperature
Typ. 110
℃
Environment
Storage
Ambient operating
temperature
Maximum case
temperature
www.pairuigroup.com
Tstorage
Humidity: 5% RH to 95% RH
-40
--
+85
℃
Ta
Startup at rated voltage
-40
--
+70
℃
Tc
Hot-spot on case
--
--
+90
℃
Page: 2 / 4
Date: 08/28/2014
Constant current LED Drivers
For outdoor use
LGU-150C Series, 150 Watt
ELECTRICAL
Environment
Parameters
Operating relative
humidity
MTBF
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Ha
Non condensing
10
--
95
%
--
400
--
kHrs
TMTBF
Dimension(LxWxH)
Full load, 220Vac input,
℃
25
ambient temperature
L: 188.5x78.5x37mm/W: 184.5x87x39.5mm
Weight
L: 850g / W: 1000g
Safety / EMC
Safety standards
EMC
UL8750, UL935, UL1012, UL1310 CLASS 2, EN61347-1, EN61347-2-13
EN55015, FCC Part 15 Class B, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11,
EN61547
Notes: Unless otherwise specified, all the above parameters are measured at ambient temperature of 25
Vin = 100Vac to 277Vac.
℃
and
MECHANICAL
PACKAGE TYPE “L”
Unit: mm
www.pairuigroup.com
Page: 3 / 4
Date: 08/28/2014
Constant current LED Drivers
For outdoor use
LGU-150C Series, 150 Watt
MECHANICAL
PACKAGE TYPE “W”
Unit: mm
DERATING CURVE
www.pairuigroup.com
STATIC CHARACTERISTIC CURVE
Page: 4 / 4
Date: 08/28/2014