PBMPLS-RM Series INVERTERS 5 0 0 - 5 0 0 0 W AT T S D C / A C I N V E R T E R FEATURES • • • • • • • True sinewave waveform Massive inrush and overload capability Galvanically isolated High efficiency toroidal transformer DC circuit breaker/ BATT isolator switch Rack mounted design LED status indicators SPECIFICATIONS OPTIONS INPUT Voltage Voltage range 12, 24, 48, 96, 120 (Standard). 36, 72, and others (Also available). -20% to +45% of nominal. OUTPUT CODE ADD OPTION TO THE END OF INVERTER PART NUMBER L Alarm output – Voltage free contacts. O Transfer alarm. KX Automatic AC transfer switch with voltage sensing. V J Voltage 240Vac ±4% (Standard). 110Vac ±4% (Option). Frequency 50/60Hz ±0.1 Output waveform True sinewave < 4% THD. Power factor correction All conditions. Crest factor >4 B 110Vac output. Psophonometric noise to ETS 3000132-2 (Available only on 48Vdc, 6000W to 1800W models) High voltage isolation 2kV AC RMS 1 minute Load start sensitivity 0-20W D RCD/Earth leakage DC to AC isolation 3500V G Mil spec conformal coating Over-load protection Over-temperature protection Short circuit protection BATT under and over voltage protection LED status indicators Yes. Yes. R Ruggedisation for high vibration environment. H Frequency 60Hz L “AC OK” alarm relay contact C Twin switched GPO D Twin switched RCD GPO Yes. Yes. ON, standby mode, over-temperature, overload, BATT under voltage, BATT over-voltage. OPERATING AC Outlet Screw terminal junction box. Battery Leads Heavy duty low loss battery leads. Dimensions 19”, 3RU x 350mm (D) – all models. Cooling Thermostatically controlled 2-speed fan. Anderson 175 Amp connectors battery leads Anderson 120 Amp connectors battery leads Anderson 75 Amp connectors battery leads STANDARDS AND APPROVALS Safety standards AS3100, AS3000 C-tick AS/NZS CISPR14, AS/NZS 1044 EMC standards AS2279, AS3000, AS3100 and EN55014 ENVIRONMENTAL Temperature Range -10°C to 50°C, derate above 40°C by 10% Doc. No. PBC9 Rev.C 28-4-11 Powering Progress – www.powerbox.com.au 529 INVERTERS PBMPLS-RM Series 530 5 0 0 - 5 0 0 0 W AT T S D C / A C I N V E R T E R SELECTION TABLE MODEL NUMBER DC INPUT INPUT RANGE CONT. RATING ½ HOUR RATING SURGE 5 SEC PEAK EFF% WEIGHT PBMPLS-12U-RM 12V 10-17V 500W 550W 1500W 90% 7KG PBMPLS-24X-RM 24V 21-34V PBMPLS-48X-RM 48V 42-68V 600W 750W 2000W 92% 7KG 600W 750W 2000W 93% 7KG PBMPLS-96X-RM 96V PBMPLS-120X-RM 120V 80-140V 600W 750W 2000W 93% 7KG 96-160V 600W 750W 2000W 93% 7KG PBMPLS-12W-RM PBMPLS-24V-RM 12V 10-17V 1000W 1150W 3000W 91% 12KG 24V 21-34V 1200W 1600W 3600W 92% 12KG PBMPLS-48V-RM 48V 42-68V 1200W 1600W 3600W 94% 12KG PBMPLS-96V-RM 96V 80-140V 1200W 1600W 3600W 94% 12KG PBMPLS-120V-RM 120V 96-160V 1200W 1600W 3600W 94% 12KG PBMPLS-12V-RM 12V 10-17V 1500W 1600W 4500W 91% 16KG PBMPLS-24I-RM 24V 21-34V 1800W 2200W 5400W 94% 16KG PBMPLS-48I-RM 48V 42-68V 1800W 2200W 5400W 94% 16KG PBMPLS-96I-RM 96V 80-140V 1800W 2200W 5400W 94% 16KG PBMPLS-120I-RM 120V 96-160V 1800W 2200W 5400W 94% 16KG PBMPLS-12I-RM 12V 10-17V 2000W 2200W 6000W 90% 22KG PBMPLS-24IA-RM 24V 21-34V 2300W 2800W 7000W 94% 22KG PBMPLS-48IA-RM 48V 42-68V 2500W 3000W 7500W 94% 22KG PBMPLS-96IA-RM 96V 80-140V 2500W 3000W 7500W 94% 22KG PBMPLS-120IA-RM 120V 96-160V 2500W 3000W 7500W 94% 22KG PBMPLS-24Z-RM 24V 21-34V 3000W 3700W 9000W 93% 24KG PBMPLS-48Z-RM 48V 42-68V 3500W 4100W 10500W 94% 24KG PBMPLS-96Z-RM 96V 80-140V 3500W 4100W 10500W 94% 24KG PBMPLS-120Z-RM 120V 96-160V 3500W 4100W 10500W 95% 24KG PBMPLS-48ZC-RM 48V 42-68V 5000W 6000W 15000W 95% 30KG Doc. No. PBC9 Rev.C 28-4-11