PBMPLS-RM Series

PBMPLS-RM Series
INVERTERS
5 0 0 - 5 0 0 0 W AT T S D C / A C I N V E R T E R
FEATURES
•
•
•
•
•
•
•
True sinewave waveform
Massive inrush and overload capability
Galvanically isolated
High efficiency toroidal transformer
DC circuit breaker/ BATT isolator switch
Rack mounted design
LED status indicators
SPECIFICATIONS
OPTIONS
INPUT
Voltage
Voltage range
12, 24, 48, 96, 120 (Standard). 36, 72, and
others (Also available).
-20% to +45% of nominal.
OUTPUT
CODE
ADD OPTION TO THE END OF INVERTER
PART NUMBER
L
Alarm output – Voltage free contacts.
O
Transfer alarm.
KX
Automatic AC transfer switch with voltage sensing.
V
J
Voltage
240Vac ±4% (Standard). 110Vac ±4% (Option).
Frequency
50/60Hz ±0.1
Output waveform
True sinewave < 4% THD.
Power factor correction
All conditions.
Crest factor
>4
B
110Vac output.
Psophonometric noise to ETS 3000132-2
(Available only on 48Vdc, 6000W to 1800W models)
High voltage isolation 2kV AC RMS 1 minute
Load start sensitivity
0-20W
D
RCD/Earth leakage
DC to AC isolation
3500V
G
Mil spec conformal coating
Over-load protection
Over-temperature
protection
Short circuit protection
BATT under and over
voltage protection
LED status indicators
Yes.
Yes.
R
Ruggedisation for high vibration environment.
H
Frequency 60Hz
L
“AC OK” alarm relay contact
C
Twin switched GPO
D
Twin switched RCD GPO
Yes.
Yes.
ON, standby mode, over-temperature, overload, BATT under voltage, BATT over-voltage.
OPERATING
AC Outlet
Screw terminal junction box.
Battery Leads
Heavy duty low loss battery leads.
Dimensions
19”, 3RU x 350mm (D) – all models.
Cooling
Thermostatically controlled 2-speed fan.
Anderson 175 Amp connectors battery leads
Anderson 120 Amp connectors battery leads
Anderson 75 Amp connectors battery leads
STANDARDS AND APPROVALS
Safety standards
AS3100, AS3000
C-tick
AS/NZS CISPR14, AS/NZS 1044
EMC standards
AS2279, AS3000, AS3100 and EN55014
ENVIRONMENTAL
Temperature Range
-10°C to 50°C, derate above 40°C by 10%
Doc. No. PBC9 Rev.C 28-4-11
Powering Progress – www.powerbox.com.au
529
INVERTERS
PBMPLS-RM Series
530
5 0 0 - 5 0 0 0 W AT T S D C / A C I N V E R T E R
SELECTION TABLE
MODEL NUMBER
DC INPUT
INPUT RANGE
CONT. RATING ½ HOUR RATING
SURGE 5 SEC
PEAK EFF%
WEIGHT
PBMPLS-12U-RM
12V
10-17V
500W
550W
1500W
90%
7KG
PBMPLS-24X-RM
24V
21-34V
PBMPLS-48X-RM
48V
42-68V
600W
750W
2000W
92%
7KG
600W
750W
2000W
93%
7KG
PBMPLS-96X-RM
96V
PBMPLS-120X-RM
120V
80-140V
600W
750W
2000W
93%
7KG
96-160V
600W
750W
2000W
93%
7KG
PBMPLS-12W-RM
PBMPLS-24V-RM
12V
10-17V
1000W
1150W
3000W
91%
12KG
24V
21-34V
1200W
1600W
3600W
92%
12KG
PBMPLS-48V-RM
48V
42-68V
1200W
1600W
3600W
94%
12KG
PBMPLS-96V-RM
96V
80-140V
1200W
1600W
3600W
94%
12KG
PBMPLS-120V-RM
120V
96-160V
1200W
1600W
3600W
94%
12KG
PBMPLS-12V-RM
12V
10-17V
1500W
1600W
4500W
91%
16KG
PBMPLS-24I-RM
24V
21-34V
1800W
2200W
5400W
94%
16KG
PBMPLS-48I-RM
48V
42-68V
1800W
2200W
5400W
94%
16KG
PBMPLS-96I-RM
96V
80-140V
1800W
2200W
5400W
94%
16KG
PBMPLS-120I-RM
120V
96-160V
1800W
2200W
5400W
94%
16KG
PBMPLS-12I-RM
12V
10-17V
2000W
2200W
6000W
90%
22KG
PBMPLS-24IA-RM
24V
21-34V
2300W
2800W
7000W
94%
22KG
PBMPLS-48IA-RM
48V
42-68V
2500W
3000W
7500W
94%
22KG
PBMPLS-96IA-RM
96V
80-140V
2500W
3000W
7500W
94%
22KG
PBMPLS-120IA-RM
120V
96-160V
2500W
3000W
7500W
94%
22KG
PBMPLS-24Z-RM
24V
21-34V
3000W
3700W
9000W
93%
24KG
PBMPLS-48Z-RM
48V
42-68V
3500W
4100W
10500W
94%
24KG
PBMPLS-96Z-RM
96V
80-140V
3500W
4100W
10500W
94%
24KG
PBMPLS-120Z-RM
120V
96-160V
3500W
4100W
10500W
95%
24KG
PBMPLS-48ZC-RM
48V
42-68V
5000W
6000W
15000W
95%
30KG
Doc. No. PBC9 Rev.C 28-4-11