MI-ComPAC MILITARY D C - D C P O W E R S U P P LY U P T O 3 0 0 W FEATURES • • • • • • • • • • Transient protection: 28 Vdc per MIL-STD-704A, MIL-STD 1275A/B/D & DO-160E, 270 Vdc per MIL-STD-704D/E/F One, two, or three outputs Outputs from 2 to 48 Vdc Up to 5 W/in 3 High efficiency Remote sense ZCS power architecture Low noise FM control MIL-STD-461C/D/E EMI compliance Reverse polarity protection PARAMETER INPUT PRODUCT INFORMATION The MI-ComPAC is a complete single, dual, or triple output DCDC power supply that delivers up to 300 W from inputs of 28 Vdc or 270 Vdc. The MI-ComPAC meets the conducted emissions and conducted susceptibility specifications of MIL-STD-461C/D/E and offers complete input transient, surge, and spike protection to the most severe levels of MIL-STD-1275, MIL-STD-704 and DO-160E. Reverse polarity protection and over / undervoltage lockout provide additional safeguards against potentially damaging line conditions. The MI-ComPAC also features a master disable. MIN All models No load power dissipation Master disable input current[b] 4 (Absolute max., 20 mA) TYP MAX UNIT 1.5[a] 2[a] Watts Inrush current 110 mA Sink; disables all outputs 125 %, Iin Steady state Iin, 10 ms EMC – MIL-STD-461C/D/E Input power leads CE01, CE03, CE07 CE101, CE102 Conducted emissions GENERAL SPECIFICATIONS CE101 At TBP = 25°C, nominal line and 75% load, unless otherwise specified CS01, CS02, CS0 PARAMETER INPUT MIN 28 Vdc input modules Steady state input Low line lockout Input spike limit 18 TYP MAX 28 UNIT –600 50 17.5 +600 Vdc Vdc Vdc –250 +250 Vdc Input surge limit Overvoltage shut down 100 Vdc 80 Vdc 50 Automatic recovery 10 µs, 50 Ω per MIL-STD-704A 70 µs, 15 mJ per MIL-STD-1275A/B/D 50 ms, 0.5 per MIL-STD-175A/B/D 100 ms per DO-160E Vdc 100 ms automatic recovery Reverse polarity protection Recommended fuse 270 Vdc input modules Steady state input Low line lockout Input spike limit Shunt diode: input fuse required 125 –600 Input surge limit Overvoltage shut down NOTE 270 10[a] Amps 400 125 +800 +600 Vdc Vdc Vdc Vdc Automatic recovery 10 µs, 50 100 µs, 15 mJ 500 Vdc 100 ms, 0.5 Vdc 100 µs automatic recovery 400 Reverse polarity protection Recommended fuse Doc. No. PBC9 Rev.C 28-4-11 2[a] Amps F03A type Shunt diode: input fuse required F03A type NOTE Conducted susceptibility CS101, CS114, CS116 CS101, CS114, CS116 MIL-STD-461C — 1-up MIL-STD-461D — 1-up MIL-STD-461E — 2-up & 3-up MIL-STD-461C — 1-up MIL-STD-461D — 1-up MIL-STD-461E — 2-up & 3-up OUTPUT Set point accuracy Load / line regulation Output temperature drift Output noise – p-p Output voltage trimming[c] Remote sense compensation OVP set point Current limit Short circuit current[d] 0.5 1.0 % Vnom 0.2 0.5 0.05 0.2 % Vnom LL to HL, NL to 10% % Vnom LL to HL, 10% to FL 0.01 1.0 0.02 1.5 100 150 %/°C % Vnom Whichever is greater mV 20 MHz BW 110 % Vnom 135 125 Vdc % Vnom Latching % Inom Auto restart 130 % Inom 50 0.5 115 105 20 125 [a] Per internal module configuration [b] Multiply minimum x 2 for 2-ups and x 3 for 3-ups [c] 10 V, 12 V, and 15 V outputs, standard trim range ±10%. Consult factory for wider trim range [d] Output ranges of 5 V or less incorporate foldback current limiting, outputs of 10 V and above incorporate straight line current limiting Powering Progress – www.powerbox.com.au 453 MILITARY MI-ComPAC D C - D C P O W E R S U P P LY U P T O 3 0 0 W PARAMETER INPUT MIN TYP MAX UNIT NOTE ISOLATION Input to output Input to case 28 Vdc input 270 Vdc input Output to case 4,242 Vrms 2,121 2,500 500 Vrms Vrms Vrms THERMAL 81 Efficiency Operating temperature, case % Storage temperature Shut down temperature +90 +95 +85 ˚C See product grade +100 ˚C See product grade +105 ˚C Cool and recycle power to restart CONFIGURATION CHART OUTPUT POWER WEIGHT NO. OF MODULES 8.6" x 2.5" x 0.99" 1.2 lbs. 1 219,2 x 64,5 x 25,1 mm (544 g) SIZE SINGLE OUTPUTS MI-LC – MI-MC 50 – 100 W – MI-NC 150 – 200 W – 300 W 8.6" x 4.9" x 0.99" 2.4 lbs. 219,2 x 126,0 x 25,1 mm (1248 g) 8.6" x 7.3" x 0.99" 3.6 lbs. 219,2 x 187,5 x 25,1 mm (1633 g) 2 3 DUAL OUTPUTS MI-PC – MI-QC 100 – 200 W – 200 – 300 W 8.6" x 4.9" x 0.99" 2.4 lbs. 219,2 x 126,0 x 25,1 mm (1248 g) 8.6" x 7.3" x 0.99" 3.6 lbs. 219,2 x 187,5 x 25,1 mm (1633 g) 8.6" x 7.3" x 0.99" 3.6 lbs. 219,2 x 187,5 x 25,1 mm (1633 g) 2 3 TRIPLE OUTPUTS MI-RC – 150 – 300 W 3 Conduction-cooled models available, add "–CC" to the end of the part number. (Consult factory for details) Nominal Range Transient 2 = 28 Vdc 5 = 155 Vdc 6 = 270 Vdc 7 = 165 Vdc 18 – 50 V[b] 100 – 210 V 125 – 400 V[c] 100 – 310 V[d] 60 V 230 V 475 V Output Power / Current Full Size 5V Y = 50 W X = 75 W W = 100 W V=— <5 V 10 A 15 A 20 A 30 A Product Grade Output Voltage Input Voltage T = 6.5 V[e] R = 7.5 V[e] M = 10 V 1 = 12 V P = 13.8 V 2 = 15 V Z=2V Y = 3.3 V 0=5V X = 5.2 V W = 5.5 V V = 5.8 V Output Power / Current Half Size 5V <5 V A = 10 W — Z = 25 W 5A Y = 50 W 10 A N = 18.5 V 3 = 24 V L = 28 V J = 36 V K = 40 V 4 = 48 V V U S = = = 5V <5 V 150 W 200 W — 30 A — 60 A I = –40°C to +85°C M = –55°C to +85°C Output Power / Current S P = = 5V <5 V 300 W — — 90 A [b] 16 V operation at 75% load [c] These units rated at 75% load from 125 – 150 Vin: Full-size – 5 Vout @ 100 W; 2 Vout and 3.3 Vout @ 30 A: Half-Size – 5 Vout @ 50 W; 2 V and 3.3 V @ 10 A [d] For use with Vicor’s MI-AIM [e] 75 W max module power for 28 V input 454 Doc. No. PBC9 Rev.C 28-4-11 MI-ComPAC MILITARY D C - D C P O W E R S U P P LY U P T O 3 0 0 W MECHANICAL DRAWING Measure case temperature on this surface. 0.99 (25,15) 0.5 (12,57) STANDARD UNITS 8.63 ±.025 (219,2 ±,64) 0.41 (10,4) 1.37 (34,80) 1.12 0.5 (12,57) (28,4) OPTIONAL HEATSINK (H1) 9.25 ±.120 (235,0 ±3,05) 0.62 (15,8) 2.5 (63,5) 7.3 (185,4) 4.9 (124,5) 8.63 (219,2) Single Doc. No. PBC9 Rev.C 28-4-11 Single or Dual Single, Dual or Triple Powering Progress – www.powerbox.com.au 455