Compac DC-DC CONVERTERS 5 0 - 6 0 0 W AT T S D C / D C S I N G L E - M U LT I L O W P R O F I L E FEATURES • • • • • • Inputs: 24, 48 and 300VDC High surge withstand: Bellcore, British Telecom BTR 2511, EN-61000-4-5 EMI/RFI specifications: Bellcore TR-TSY-000513, British Telecom BTR 2511 UL, CSA, TÜV, VDE, BABT, CE, C-Tick Conduction Cooled Model Option Reverse polarity protected SPECIFICATIONS SELECTION TABLE INPUT Input voltage 24VDC, 48VDC & 300VDC Input transient protection Yes Reverse polarity protection Yes External fuses required OUTPUT Output voltage See table (any output from 1–95VDC) Output power See table Product grade E,C,I,M Set point accuracy 0.5% Output ripple 1.5% pk-pk max Load regulation 0.05% Line regulation 0.05% OVP set point 125% Current limit setting Low–High trim voltage program 105%–125% 50%–110% Remote Sense Compensation Single output VI-LC VI-MC VI-NC VI-PC Dual output VI-QC Triple output VI-RC [a] [b] – [c] [d]50–200W [a] [b] – [c] [e]100–400W [a] [b] – [c] [f]300–600W [a] [b] [b] – [c] [d] [d]100–400W [a] [b] [b] – [c] [e] [d]150–600W [a] [b] [b] [b] – [c] [d] [d] [d]150–600W # For conduction cooled models add – cc at end of model number Please substitute selection character (e.g. [a]) with value designator in the appropriate table below. A = INPUT VOLTAGE NOMINAL 1= 24V W= 24V 3= 48V N= 48V 6= 300V B = OUTPUT VOLTAGE RANGE POWER MAX 21–32V 18–36V 42–60V 36–76V 200–400V (1) (1) (2) (2) (2) 0.5V OPERATING Efficiency 80%–90% typ Isolation input – output 4,242Vdc Baseplate operating temp. 85°C Shutdown temperature C = PRODUCT GRADE 105°C max STANDARDS AND APPROVALS Safety standards UL1604, UL/C5A/EN/IEC609501 C-Tick AAS/NZS CISPR11 Group 1, Class A EMC standards IEC61000-4-5 Level 2 IEC61000-4-2 Level 4 British Telecom BTR 2511, Issue 2, EN55022 Class B EMI standards Input transient protection IEC801-5 MECHANICAL SPECIFICATIONS Dimensions (LxWxH) VI-LC: 219x64x25mm VI-MC, PC: 219x125x25mm VI-NC, QC, RC: 219x186x25mm Z= 2V Y= 3.3V 0= 5V M= 10V 1= 12V 2= 15V 3= 24V L= 28V 4= 48V 1–95V, consult Powerbox D = OUTPUT POWER/CURRENT E= -10°C to +85°C C= -25°C to +85°C I= -40°C to +85°C V out >5V Y = 50W X = 75W W = 100W V out <5V 10A 15A 20A M= -55°C to +85°C V = 150W 30A U= 200W 40A E = OUTPUT POWER/CURRENT V out >5V W= 100W V= 150W U= 200W S= 300W Q= 400W V out <5V 20A 30A 40A 60A 80A F = OUTPUT POWER/CURRENT V out >5V S = 300W P = 450W M = 600W V out <5V 60A 90A 120A >5V Outputs 150W 200W <5V Outputs 30A 40A NOTES: Maximum Output Power (1) (2) 5V Outputs 150W 200W Please consult Powerbox office for other output voltage and thermal application notes. Doc. No. PBC9 Rev.D 8-8-2012 Powering Progress – www.powerbox.com.au 115 DC-DC CONVERTERS Compac 5 0 - 6 0 0 W AT T S D C / D C S I N G L E - M U LT I TECHNICAL ILLUSTRATION ALL MODELS INPUTS 1 2 3 4 5 Ground Input +Input Disable Disable OUTPUTS A B C D E +Output +Sense Trim -Sense -Output LC SERIES MC, PC SERIES NC, QC, RC SERIES 116 DOC. NO. PBC9 REV.D 8-8-12