VIPAC Power System FEATURES • • • • • • AC input 115/230VAC Autoranging 50-400Hz Protective features: inrush current limiting, input transient protection, EMI filtering, auto restart Pre-assembled and tested front end FARM module Microprocessor control with RS232 style communication port Configurable single or multiple outputs Choice of output terminations 115/230VAC AUTORANGING INPUT Operating input voltage 90-132VAC (Doubler mode) 180-264VAC (Bridge mode) Input under-voltage Shut Down90VAC (No damage) Humidity 5-95%, Non-condensing Safety approvals cTÜVus (CSA-C22.2 NO. 60950-00, UL1950 3rd Ed. 2000, EN60950:2000), CE Marked (LVD) OUTPUT SPECIFICATIONS -GENERAL AC line frequency 47-63Hz (C-Grade) 47-440Hz (T-Grade) Output voltage set-point Power factor 0.60, Nominal Line Line regulation Inrush current 60A, 264VAC peak line, cold start Input surge withstand (Verification pending) EN61000-4-5, 2KV-50ìs common mode, 1KV50ìs differential mode 1800mF (typ), 3300mF(max), refer to VCAD calculator Hold-up capacitance Leakage current 3.2mA at 264VAC input EMI Additional filter components are required for compliance to EN55022 and FCC Class B conducted emissions requirements. Temperature regulation Over-temperature Shutdown Power sharing accuracy Programming range ENVIRONMENTAL Current limit Dielectric withstand (Input 1500VRMS to Chassis) Operating temperature -20oC to +65oC (C-Grade) -40oC to +65? (TGrade) Max. chassis temperature, 95oC Shock 50g, GR 6063, NEBS, Zone4 (pending) Doc. No. PBC9 Rev.C 28-4-11 Short circuit current Powering Progress – www.powerbox.com.au +/-1% Vout nom +/-0.02% (typ), +/-0.2% (max) Low line to high line; full load +/-0.002%/OC (typ), +/-0.005%/oC(max) Over operating temp. range 115oC +/-2% (typ), +/-5% (max) 10% to 100% of full load 10-110% of nominal output voltage. (For timing behavior 90% of Vout nom, a minimum load of 10% of maximum rated power may be required) 115% Iout max. Output voltage 95% of nominal 115% Iout max. Output voltage <250mV DC-DC PCB MOUNTED CONVERTERS & POWER MODULES 5 0 - 9 0 0 W AT T S - A C / D C S I N G L E & M U LT I P L E O U T P U T C O N F I G U R A B L E 279 DC-DC PCB MOUNTED CONVERTERS & POWER MODULES VIPAC Power System 280 5 0 - 9 0 0 W AT T S - A C / D C S I N G L E & M U LT I P L E O U T P U T C O N F I G U R A B L E CONFIGURATION 2V 3.3 V 5V 12 V VP-D VP-A # Outputs Single 24 V 28 V 36 V 48 V TOTAL MAX. MODULE OUTPUT POWER (W)* MICRO VP-G 15 V 50 75 100 150 150 150 150 150 150 150 Single ll 100 150 200 300 300 300 300 300 300 300 Dual 50 75 100 150 150 150 150 150 150 50 75 100 150 150 150 150 150 150 100 150 200 300 300 300 300 300 300 50 75 100 150 150 150 150 150 150 50 75 100 150 150 150 150 150 150 50 75 100 150 150 150 150 150 150 50 75 100 150 150 150 150 150 150 Dual ll Triple 300 450 450 MAX. MODULE OUTPUT POWER (W)* MINI VP-E VP-B Single 100 150 200 250 250 250 250 250 250 250 Single ll 200 300 400 500 500 500 500 500 500 500 Dual 100 100 150 150 200 200 250 250 250 100 150 200 250 250 250 250 250 250 500 MAX. MODULE OUTPUT POWER (W)* MAXI VP-F VP-C Single 160 264 400 500 500 500 500 500 500 500 Single ll 320 528 800 900 900 900 900 900 900 900 Dual 160 160 264 264 400 400 500 500 500 500 500 500 500 500 500 500 500 500 900 *Model numbers and total output power capability are application specific. Component tolerances may effect total output power (±5%) in parallel (//) configurations. See Powerbox Sales for further information. Doc. No. PBC9 Rev.C 28-4-11