VIPAC Power System

VIPAC Power System
FEATURES
•
•
•
•
•
•
AC input 115/230VAC Autoranging 50-400Hz
Protective features: inrush current limiting, input
transient protection, EMI filtering, auto restart
Pre-assembled and tested front end FARM
module
Microprocessor control with RS232 style
communication port
Configurable single or multiple outputs
Choice of output terminations
115/230VAC AUTORANGING INPUT
Operating input voltage
90-132VAC (Doubler mode) 180-264VAC
(Bridge mode)
Input under-voltage
Shut Down90VAC (No damage)
Humidity
5-95%, Non-condensing
Safety approvals
cTÜVus (CSA-C22.2 NO. 60950-00, UL1950 3rd
Ed. 2000, EN60950:2000), CE Marked (LVD)
OUTPUT SPECIFICATIONS -GENERAL
AC line frequency
47-63Hz (C-Grade) 47-440Hz (T-Grade)
Output voltage set-point
Power factor
0.60, Nominal Line
Line regulation
Inrush current
60A, 264VAC peak line, cold start
Input surge withstand
(Verification pending)
EN61000-4-5, 2KV-50ìs common mode, 1KV50ìs differential mode
1800mF (typ), 3300mF(max), refer to VCAD
calculator
Hold-up capacitance
Leakage current
3.2mA at 264VAC input
EMI
Additional filter components are required for
compliance to EN55022 and FCC Class B
conducted emissions requirements.
Temperature regulation
Over-temperature
Shutdown
Power sharing accuracy
Programming range
ENVIRONMENTAL
Current limit
Dielectric withstand (Input 1500VRMS
to Chassis)
Operating temperature
-20oC to +65oC (C-Grade) -40oC to +65? (TGrade) Max. chassis temperature, 95oC
Shock
50g, GR 6063, NEBS, Zone4 (pending)
Doc. No. PBC9 Rev.C 28-4-11
Short circuit current
Powering Progress – www.powerbox.com.au
+/-1% Vout nom
+/-0.02% (typ), +/-0.2% (max) Low line to
high line; full load
+/-0.002%/OC (typ), +/-0.005%/oC(max) Over
operating temp. range
115oC
+/-2% (typ), +/-5% (max) 10% to
100% of full load
10-110% of nominal output voltage.
(For timing behavior 90% of Vout nom, a
minimum load of 10% of maximum rated
power may be required)
115% Iout max. Output voltage 95%
of nominal
115% Iout max. Output voltage <250mV
DC-DC PCB MOUNTED CONVERTERS & POWER MODULES
5 0 - 9 0 0 W AT T S - A C / D C S I N G L E & M U LT I P L E O U T P U T C O N F I G U R A B L E
279
DC-DC PCB MOUNTED CONVERTERS & POWER MODULES
VIPAC Power System
280
5 0 - 9 0 0 W AT T S - A C / D C S I N G L E & M U LT I P L E O U T P U T C O N F I G U R A B L E
CONFIGURATION
2V
3.3 V
5V
12 V
VP-D
VP-A
# Outputs
Single
24 V
28 V
36 V
48 V
TOTAL
MAX.
MODULE OUTPUT POWER (W)*
MICRO
VP-G
15 V
50
75
100
150
150
150
150
150
150
150
Single ll
100
150
200
300
300
300
300
300
300
300
Dual
50
75
100
150
150
150
150
150
150
50
75
100
150
150
150
150
150
150
100
150
200
300
300
300
300
300
300
50
75
100
150
150
150
150
150
150
50
75
100
150
150
150
150
150
150
50
75
100
150
150
150
150
150
150
50
75
100
150
150
150
150
150
150
Dual ll
Triple
300
450
450
MAX.
MODULE OUTPUT POWER (W)*
MINI
VP-E
VP-B
Single
100
150
200
250
250
250
250
250
250
250
Single ll
200
300
400
500
500
500
500
500
500
500
Dual
100
100
150
150
200
200
250
250
250
100
150
200
250
250
250
250
250
250
500
MAX.
MODULE OUTPUT POWER (W)*
MAXI
VP-F
VP-C
Single
160
264
400
500
500
500
500
500
500
500
Single ll
320
528
800
900
900
900
900
900
900
900
Dual
160
160
264
264
400
400
500
500
500
500
500
500
500
500
500
500
500
500
900
*Model numbers and total output power capability are application specific.
Component tolerances may effect total output power (±5%) in parallel (//) configurations.
See Powerbox Sales for further information.
Doc. No. PBC9 Rev.C 28-4-11