Data Sheet MIL-COTS VIPAC Array Low Profile, Configurable Power Solution Features • Inputs: 24, 28, or 300 Vdc 48, 72, 110, 150, and 375 Vdc inputs also available • -55 °C operation • Configurable single, dual, triple and quad outputs • Any output: 0.5 – 48 Vdc; up to 650 W Configurations 2 Minis (A) • 3.62" x 6.69" • Current share option for high power/ redundant operation (92,0 x 170,0 mm) • Fully connectorized input & output for simplified hook up • Single or dual outputs • Up to 600 W total • 1.25 lbs. (567 g) • Rugged, low profile, cold plate chassis 1 Mini, 2 Micros (B) • 3.62" x 6.69" (92,0 x 170,0 mm) • High temperature capability • Single, dual or triple outputs • Up to 600 W total • 1.3 lbs. (590 g) • Environmental stress screening (modules only) 3 Micros (C) • Compliant to MIL-STD-810F for vibration (Method 514.5, Procedure I) and shock (Method 516.5, Procedure I) • 3.62" x 6.69" (92,0 x 170,0 mm) • Dual or triple outputs • Up to 450 W total • 1.3 lbs. (590 g) Product Highlights 1 Maxi (D/J) VIPAC Arrays are a highly flexible system of DC input, power building-blocks that can be configured with as many as four user definable outputs on a low profile, cold plate chassis. Using Vicor's VCAD design tool, designers are able to specify VIPAC Arrays with Maxi, Mini and Micro product series H or M grade converters with nominal inputs from 24 to 375 Vdc and outputs from 2 to 48 Vdc at power levels up to 600 W per output. VIPAC Arrays are ideal for use in distributed and modular power systems where power density and reliable operation are critical. A current share option is available on single output models enabling them to be used in applications requiring high power / redundancy. Fully connectorized input and output terminations speed system installation and a versatile cold plate chassis simplifies thermal management. • 3.62" x 6.69" (92,0 x 170,0 mm) 1 Micro, 2 Minis (E) • 3.62" x 7.52" (92,0 x 191,0 mm) • Dual or triple outputs • Up to 750 W total • 1.35 lbs. (612 g) 4 Micros (F) • 3.62" x 7.52" (92,0 x 191,0 mm) • Dual, triple, or quad outputs • Up to 600 W total • 1.3 lbs. (590 g) 1 Mini (G/K) • 3.62" x 4.39" (92,0 x 112,0 mm) • 0.7 lbs. (318 g) For additional technical or design information; or to create a VIPAC Array tailored to your specific requirements using Vicor’s online configurator, please visit www.vicorpower.com. Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 • 1.05 lbs. (476 g) • Single output • Up to 600 W • Current share option • Single output • Up to 300 W total • Current share option 2 Micros (H) • 3.62" x 4.39" (92,0 x 112,0 mm) • Single or dual outputs • Up to 300 W total • 0.7 lbs. (318 g) MIL VIPAC Array Set your site on VICOR at vicorpower.com Rev. 1.6 Page 1 of 5 MIL VIPAC ARRAY GENERAL SPECIFICATIONS Typical at 25 °C, nominal line and load, unless otherwise specified. For technical information refer to “Design Guide & Applications Manual for Maxi, Mini, Micro Family DC-DC Converters and Accessory Modules” and/or the "VIPAC Array Power Systems Configuration Guide". See the respective converter family datasheet for electrical details. These are available at www.vicorpower.com ENVIRONMENTAL - SYSTEM Parameter Min Dielectric withstand, input to chassis Typ Max 1500/2121 Unit Notes Vrms/Vdc Operating chassis temperature H-grade -40 95 °C M-grade -55 95 °C -55 125 °C -65 125 °C Storage temperature H-Grade M-Grade Shock MIL-STD-810F, Method 514.5, Procedure I 40 g for 15-23 ms, 75 g for 8-13 ms Vibration MIL-STD-810F, Method 516.5, Procedure I 20-2000 Hz at 5 g ENVIRONMENTAL MODULES ONLY Altitude MIL-STD-810C, Method 500.2, Procedure I & II, 40,000 ft. and 70,000 ft. Operational. Explosive Atmosphere MIL-STD-810F, Method 511.4, Procedure I, Operational. Vibration MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J Main Rotor with overall level of 5.6 grams for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity Curve per Figure 514.5C-17 with overall level of 7.7 grams for 1 hour per axis. Shock MIL-STD-810-F, Method 516.5, Procedure I, Functional Shock, 40 G's. MIL-S-901D, Lightweight Hammer Shock, 3 impacts/axis, 1,3,5 ft. MIL-STD-202F, Method 213B, 60 G's, 9ms half sine. MIL-STD-202F, Method 213B, 75 G's, 11ms Saw Tooth Shock. Acceleration MIL-STD-810F, Method 513.5, Procedure II, Table 513.5-II, Operational, 2-7 G's, 6 directions. Humidity MIL-STD-810F, Method 507.4, Procedure I, Cycle I, 240 hrs, 95% RH. Solder Test MIL-STD-202F, Method 208, 8 hour aging. Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 MIL VIPAC Array Set your site on VICOR at vicorpower.com Rev. 1.6 Page 2 of 5 MECHANICAL DRAWINGS Configuration VA-A LugMates Configuration VA-B LugMates 3.62 92 3.62 Inches MM 0.197 5 3.228 82 INCHES MM 92 3.228 82 0.197 5 0.36 9,1 #4-40 STUD FITS 2 LUGS MIN (VICOR P/N 23519) TORQUE TO 4 in. lbs. 4 PLACES #10-32 Stud fits 2 lugs min (Vicor P/N 23520) torque to 16 in. lbs. 4 places 3 0.70 17,8 6.69 170 0.70 17,8 2 2 1.35 34,3 6.69 170 5.36 136,2 6.299 160 6.299 160 3.189 81 3.81 96,8 3.189 81 1.35 34,3 1 1 1.35 34,3 3.85 97,8 1.57 39,9 0.197 5 1.57 39,9 0.197 5 Mount (6) plusing #8 flat head screw (M4 flat head screw) torque to 12 in. lbs. 0.26 6,6 MOUNT (6) PL USING #8 FLAT HEAD SCREW (M4 FLAT HEAD SCREW) TORQUE TO 12 in. lbs. 0.26 6,6 0.78 19,9 #10-32 STUD FITS 2 LUGS MIN (VICOR P/N 23520) TORQUE TO 16 in. lbs. 2 PLACES 0.78 19,9 Configuration VA-C LugMates Configuration VA-D/J LugMates 3.62 92 3.62 92 #4-40 STUD FITS 2 LUGS MIN (VICOR P/N 23519) TORQUE TO 4 in. lbs. 6 PLACES 3.228 82 INCHES MM 0.197 5 1.14 28,9 INCHES MM 1.35 34,3 #10-32 STUD FITS 2 LUGS MIN (VICOR P/N 23520) TORQUE TO 16 in. lbs. 2 PLACES 3 0.70 17,8 6.69 170 2 0.70 17,8 6.69 170 0.27 6,8 1 6.299 160 6.299 160 3.81 96,8 1 0.70 17,8 5.36 136,2 3.189 81 0.197 5 MOUNT (6) PL USING #8 FLAT HEAD SCREW (M4 FLAT HEAD SCREW) TORQUE TO 12 in. lbs. 1.90 48,2 3.189 81 MOUNT (6) PL USING #8 FLAT HEAD SCREW (M4 FLAT HEAD SCREW TORQUE TO 12 in. lbs. 0.197 5 0.36 9,1 0.197 5 3.228 82 0.78 19,9 0.76 19,3 Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 MIL VIPAC Array Set your site on VICOR at vicorpower.com Rev. 1.6 Page 3 of 5 MECHANICAL DRAWINGS (CONT.) Configuration VA-F LugMates Configuration VA-E LugMates 3.62 92 INCHES MM 0.197 5 3.62 92 #10-32 STUD FITS 2 LUGS MIN (VICOR P/N 23520) TORQUE TO 16 in. lbs. 4 PLACES 3.228 82 #4-40 STUD FITS 2 LUGS MIN (VICOR P/N 23519) TORQUE TO 4 in. lbs. 8 PLACES 0.197 5 0.70 17,8 4 0.26 6,6 3.228 82 INCHES MM 5.43 137,8 1.35 34,3 2 7.52 0.70 17,8 3 3 1.35 34,3 6.19 157,2 7.52 191 0.70 17,8 2 191 7.126 181 7.126 181 3.15 3.09 78,4 79,9 1 0.70 17,8 121 4.016 102 0.197 5 0.197 1.55 39,3 5 #4-40 STUD FITS 2 LUGS MIN (VICOR P/N 23519) TORQUE TO 4 in. lbs. 2 PLACES 0.36 9,1 MOUNT (6) PL USING #8 FLAT HEAD SCREW (M4 FLAT HEAD SCREW) TORQUE TO 12 in. lbs. 0.70 17,8 1 4.764 1.54 39,1 0.36 9,1 MOUNT (6) PL USING #8 FLAT HEAD SCREW (M4 FLAT HEAD SCREW) TORQUE TO 12 in. lbs. 0.78 19,9 0.76 19,3 Configuration VA-G/K LugMates Configuration VA-H LugMates 3.62 92 2.24 56,8 0.26 6,7 INCHES MM #10-32 STUD FITS 2 LUGS MIN (VICOR P/N 23520) TORQUE TO 16 in. lbs. 2 PLACES 4.39 111,5 1 3.996 101,5 #4-40 STUD FITS 2 LUGS MIN (VICOR P/N 23519) TORQUE TO 4 in. lbs. 4 PLACES 0.69 17,4 0.31 8 4.39 111,5 4.6 3.996 101,5 118 0.197 5 0.197 5 MOUNT (4) PL USING #8 FLAT HEAD SCREW (M4 FLAT HEAD SCREW) TORQUE TO 12 in. lbs. 0.197 5 0.70 17,8 0.70 17,8 2 1.14 28,9 1.35 34,3 1 INCHES MM 4.64 117,8 0.197 5 3.228 82 3.62 92 3.228 82 .78 0.78 19,9 19.9 Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 MOUNT (4) PL USING #8 FLAT HEAD SCREW (M4 FLAT HEAD SCREW) TORQUE TO 12 in. lbs. MIL VIPAC Array Set your site on VICOR at vicorpower.com Rev. 1.6 Page 4 of 5 Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems. Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. Specifications are subject to change without notice. Vicor’s Standard Terms and Conditions All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request. Product Warranty In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the “Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment and is not transferable. UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DISCLAIMS ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW) WITH RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MATTER. This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and operating safeguards. Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty. Life Support Policy VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages. Intellectual Property Notice Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is granted by this document. Interested parties should contact Vicor's Intellectual Property Department. Vicor Corporation 25 Frontage Road Andover, MA, USA 01810 Tel: 800-735-6200 Fax: 978-475-6715 email Customer Service: [email protected] Technical Support: [email protected] Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 MIL VIPAC Array Set your site on VICOR at vicorpower.com Rev. 1.6 06/12