VIPAC Array Datasheet

Data Sheet
MIL-COTS VIPAC Array
Low Profile, Configurable
Power Solution
Features
• Inputs: 24, 28, or 300 Vdc
48, 72, 110, 150, and
375 Vdc inputs also available
• -55 °C operation
• Configurable single, dual, triple and
quad outputs
• Any output: 0.5 – 48 Vdc; up to 650 W
Configurations
2 Minis (A)
• 3.62" x 6.69"
• Current share option for high power/
redundant operation
(92,0 x 170,0 mm)
• Fully connectorized input & output for
simplified hook up
• Single or dual outputs
• Up to 600 W total
• 1.25 lbs. (567 g)
• Rugged, low profile, cold plate
chassis
1 Mini, 2 Micros (B)
• 3.62" x 6.69"
(92,0 x 170,0 mm)
• High temperature capability
• Single, dual or triple outputs
• Up to 600 W total
• 1.3 lbs. (590 g)
• Environmental stress screening
(modules only)
3 Micros (C)
• Compliant to MIL-STD-810F for
vibration (Method 514.5, Procedure I) and
shock (Method 516.5, Procedure I)
• 3.62" x 6.69"
(92,0 x 170,0 mm)
• Dual or triple outputs
• Up to 450 W total
• 1.3 lbs. (590 g)
Product Highlights
1 Maxi (D/J)
VIPAC Arrays are a highly flexible system
of DC input, power building-blocks that can
be configured with as many as four user
definable outputs on a low profile, cold plate
chassis. Using Vicor's VCAD design tool,
designers are able to specify VIPAC Arrays
with Maxi, Mini and Micro product series
H or M grade converters with nominal inputs
from 24 to 375 Vdc and outputs from 2 to 48
Vdc at power levels up to 600 W per output.
VIPAC Arrays are ideal for use in distributed
and modular power systems where power
density and reliable operation are critical. A
current share option is available on single
output models enabling them to be used in
applications requiring high power /
redundancy. Fully connectorized input and
output terminations speed system installation
and a versatile cold plate chassis simplifies
thermal management.
• 3.62" x 6.69"
(92,0 x 170,0 mm)
1 Micro, 2 Minis (E)
• 3.62" x 7.52"
(92,0 x 191,0 mm)
• Dual or triple outputs
• Up to 750 W total
• 1.35 lbs. (612 g)
4 Micros (F)
• 3.62" x 7.52"
(92,0 x 191,0 mm)
• Dual, triple, or quad outputs
• Up to 600 W total
• 1.3 lbs. (590 g)
1 Mini (G/K)
• 3.62" x 4.39"
(92,0 x 112,0 mm)
• 0.7 lbs. (318 g)
For additional technical or design
information; or to create a VIPAC Array
tailored to your specific requirements using
Vicor’s online configurator, please visit
www.vicorpower.com.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
• 1.05 lbs. (476 g)
• Single output
• Up to 600 W
• Current share option
• Single output
• Up to 300 W total
• Current share option
2 Micros (H)
• 3.62" x 4.39"
(92,0 x 112,0 mm)
• Single or dual outputs
• Up to 300 W total
• 0.7 lbs. (318 g)
MIL VIPAC Array
Set your site on VICOR at vicorpower.com
Rev. 1.6
Page 1 of 5
MIL VIPAC ARRAY GENERAL SPECIFICATIONS
Typical at 25 °C, nominal line and load, unless otherwise specified.
For technical information refer to “Design Guide & Applications Manual for Maxi, Mini, Micro Family DC-DC Converters and Accessory
Modules” and/or the "VIPAC Array Power Systems Configuration Guide". See the respective converter family datasheet for electrical
details. These are available at www.vicorpower.com
ENVIRONMENTAL - SYSTEM
Parameter
Min
Dielectric withstand, input to chassis
Typ
Max
1500/2121
Unit
Notes
Vrms/Vdc
Operating chassis temperature
H-grade
-40
95
°C
M-grade
-55
95
°C
-55
125
°C
-65
125
°C
Storage temperature
H-Grade
M-Grade
Shock
MIL-STD-810F, Method 514.5, Procedure I
40 g for 15-23 ms, 75 g for 8-13 ms
Vibration
MIL-STD-810F, Method 516.5, Procedure I
20-2000 Hz at 5 g
ENVIRONMENTAL MODULES ONLY
Altitude
MIL-STD-810C, Method 500.2, Procedure I & II, 40,000 ft. and 70,000 ft. Operational.
Explosive Atmosphere
MIL-STD-810F, Method 511.4, Procedure I, Operational.
Vibration
MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J Main Rotor with overall level
of 5.6 grams for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity Curve per Figure 514.5C-17 with overall level of 7.7 grams for
1 hour per axis.
Shock
MIL-STD-810-F, Method 516.5, Procedure I, Functional Shock, 40 G's. MIL-S-901D, Lightweight Hammer Shock, 3 impacts/axis, 1,3,5 ft. MIL-STD-202F,
Method 213B, 60 G's, 9ms half sine. MIL-STD-202F, Method 213B, 75 G's, 11ms Saw Tooth Shock.
Acceleration
MIL-STD-810F, Method 513.5, Procedure II, Table 513.5-II, Operational, 2-7 G's, 6 directions.
Humidity
MIL-STD-810F, Method 507.4, Procedure I, Cycle I, 240 hrs, 95% RH.
Solder Test
MIL-STD-202F, Method 208, 8 hour aging.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MIL VIPAC Array
Set your site on VICOR at vicorpower.com
Rev. 1.6
Page 2 of 5
MECHANICAL DRAWINGS
Configuration VA-A
LugMates
Configuration VA-B
LugMates
3.62
92
3.62
Inches
MM
0.197
5
3.228
82
INCHES
MM
92
3.228
82
0.197
5
0.36
9,1
#4-40 STUD
FITS 2 LUGS MIN
(VICOR P/N 23519)
TORQUE TO 4 in. lbs.
4 PLACES
#10-32 Stud
fits 2 lugs min
(Vicor P/N 23520)
torque to 16 in. lbs.
4 places
3
0.70
17,8
6.69
170
0.70
17,8
2
2
1.35
34,3
6.69
170
5.36
136,2
6.299
160
6.299
160
3.189
81
3.81
96,8
3.189
81
1.35
34,3
1
1
1.35
34,3
3.85
97,8
1.57
39,9
0.197
5
1.57
39,9
0.197
5
Mount (6) plusing
#8 flat head screw
(M4 flat head screw)
torque to 12 in. lbs.
0.26
6,6
MOUNT (6) PL USING
#8 FLAT HEAD SCREW
(M4 FLAT HEAD SCREW)
TORQUE TO 12 in. lbs.
0.26
6,6
0.78
19,9
#10-32 STUD
FITS 2 LUGS MIN
(VICOR P/N 23520)
TORQUE TO 16 in. lbs.
2 PLACES
0.78
19,9
Configuration VA-C
LugMates
Configuration VA-D/J
LugMates
3.62
92
3.62
92
#4-40 STUD
FITS 2 LUGS MIN
(VICOR P/N 23519)
TORQUE TO 4 in. lbs.
6 PLACES
3.228
82
INCHES
MM
0.197
5
1.14
28,9
INCHES
MM
1.35
34,3
#10-32 STUD
FITS 2 LUGS MIN
(VICOR P/N 23520)
TORQUE TO 16 in. lbs.
2 PLACES
3
0.70
17,8
6.69
170
2
0.70
17,8
6.69
170
0.27
6,8
1
6.299
160
6.299
160
3.81
96,8
1
0.70
17,8
5.36
136,2
3.189
81
0.197
5
MOUNT (6) PL USING
#8 FLAT HEAD SCREW
(M4 FLAT HEAD SCREW)
TORQUE TO 12 in. lbs.
1.90
48,2
3.189
81
MOUNT (6) PL USING
#8 FLAT HEAD SCREW
(M4 FLAT HEAD SCREW
TORQUE TO 12 in. lbs.
0.197
5
0.36
9,1
0.197
5
3.228
82
0.78
19,9
0.76
19,3
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MIL VIPAC Array
Set your site on VICOR at vicorpower.com
Rev. 1.6
Page 3 of 5
MECHANICAL DRAWINGS (CONT.)
Configuration VA-F
LugMates
Configuration VA-E
LugMates
3.62
92
INCHES
MM
0.197
5
3.62
92
#10-32 STUD
FITS 2 LUGS MIN
(VICOR P/N 23520)
TORQUE TO 16 in. lbs.
4 PLACES
3.228
82
#4-40 STUD
FITS 2 LUGS MIN
(VICOR P/N 23519)
TORQUE TO 4 in. lbs.
8 PLACES
0.197
5
0.70
17,8
4
0.26
6,6
3.228
82
INCHES
MM
5.43
137,8
1.35
34,3
2
7.52
0.70
17,8
3
3
1.35
34,3
6.19
157,2
7.52
191
0.70
17,8
2
191
7.126
181
7.126
181
3.15
3.09
78,4
79,9
1
0.70
17,8
121
4.016
102
0.197
5
0.197
1.55
39,3
5
#4-40 STUD
FITS 2 LUGS MIN
(VICOR P/N 23519)
TORQUE TO 4 in. lbs.
2 PLACES
0.36
9,1
MOUNT (6) PL USING
#8 FLAT HEAD SCREW
(M4 FLAT HEAD SCREW)
TORQUE TO 12 in. lbs.
0.70
17,8
1
4.764
1.54
39,1
0.36
9,1
MOUNT (6) PL USING
#8 FLAT HEAD SCREW
(M4 FLAT HEAD SCREW)
TORQUE TO 12 in. lbs.
0.78
19,9
0.76
19,3
Configuration VA-G/K
LugMates
Configuration VA-H
LugMates
3.62
92
2.24
56,8
0.26
6,7
INCHES
MM
#10-32 STUD
FITS 2 LUGS MIN
(VICOR P/N 23520)
TORQUE TO 16 in. lbs.
2 PLACES
4.39
111,5
1
3.996
101,5
#4-40 STUD
FITS 2 LUGS MIN
(VICOR P/N 23519)
TORQUE TO 4 in. lbs.
4 PLACES
0.69
17,4
0.31
8
4.39
111,5
4.6
3.996
101,5
118
0.197
5
0.197
5
MOUNT (4) PL USING
#8 FLAT HEAD SCREW
(M4 FLAT HEAD SCREW)
TORQUE TO 12 in. lbs.
0.197
5
0.70
17,8
0.70
17,8
2
1.14
28,9
1.35
34,3
1
INCHES
MM
4.64
117,8
0.197
5
3.228
82
3.62
92
3.228
82
.78
0.78
19,9
19.9
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MOUNT (4) PL USING
#8 FLAT HEAD SCREW
(M4 FLAT HEAD SCREW)
TORQUE TO 12 in. lbs.
MIL VIPAC Array
Set your site on VICOR at vicorpower.com
Rev. 1.6
Page 4 of 5
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no
representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make
changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and
is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are
used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all
parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Vicor’s Standard Terms and Conditions
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request.
Product Warranty
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the
“Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment
and is not transferable.
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DISCLAIMS
ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW) WITH
RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR
PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MATTER.
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable
for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes
no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and
components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and
operating safeguards.
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact
Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be
returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the
product was defective within the terms of this warranty.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS
PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support
devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform
when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the
user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products
and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the
products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is
granted by this document. Interested parties should contact Vicor's Intellectual Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: [email protected]
Technical Support: [email protected]
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MIL VIPAC Array
Set your site on VICOR at vicorpower.com
Rev. 1.6
06/12