DC-AC INVERTER UNIT - Power

DC-AC INVERTER UNIT
PS-DA0143-01(S) (5 W SINGLE OUTPUT)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for single lamps.
Optimized for Sharp: LQ075V3DG01, 14th Feb. 2007
APPLICABLE LCD:
Lamp Voltage 850 Vrms
Lamp Current : 6.0 mArms
Lamp Start Up Voltage 2.400 Vrms (Vin : 12 Vdc)
FEATURES :
Current balance circuit
Extra high starting Voltage
Output current set up to 4mA only.
RoHS compliant (S)
Ext. PWM Dimming
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
-30°C ~ +70°C
-30°C ~ +85°C
95 %RH max
L x B x H 100 x 30 x 9 mm
Pin 1
Pin 1
Unit : mm
Weight :15 (g) typ.
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2
Qty.
1
1
1
Material
UL94V-0 (FR-4 or CEM-3)
S5B-PH-SM3
SM02(8.0)B-BHS-1-TB
Note
t=1mm
JST or equal
JST or equal
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstraße 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.1.7, 31st August 2010
DC-AC INVERTER UNIT
PS-DA0143-01(S) (5 W SINGLE OUTPUT)
Input side CN1:
Pin No.
Symbols
Vin
CN 1-1
GND
CN 1-2
Ext. PWM
CN 1-3
N.C.
CN 1-4
Vrmt
CN 1-5
(PRELIMINARY INFORMATION)
Ratings
10.8~13.2 Vdc
0 ~ 1 Vdc Low/ 3~5 Vdc High(L activ)
-
Output side CN2
Pin No.
Symbols
Vhigh
CN 2-1
N.C.
CN 2-2
CN 2-3
Ratings
850Vrms (6mArms)
-
Vlow
GND
0 ~ 0.4 = OFF / 2.5 ~ 5.5 = ON
ELECTRICAL CHARACTERISTICS :
Conditions
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No Load Shotdown
Iout
Iout
Iin
F
Vopen
Tsd
Note 1 :
Note 2:
Note 3:
Specification
Vin (V)
Vbr (V)
Tu (°C)
Min.
Typ.
Max.
12±1.2
12±0.6
12±1.2
12±1.2
11.4
12±1.2
0.0
5.0
0.0
0.0
0.0
0.0
-30 ~ +70
-30 ~ +70
-30 ~ +70
-30 ~ +70
-30 ~ +70
-30 ~ +70
5.5
50
2.200
-
6.0
20
TBD
60
2.400
1.0
6.5
TBD
70
2.700
-
Unit
Note
mArms
%
Adc
kHz
Vrms
sec
Dut y 100%
without load
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
The external PWM frequency should be in a range of 100 ~ 500 Hz. For other frequency please request.
The optimum is normally at 250 Hz, and minimizes the interference disturbances of the vertical sync.
frequency.
Before apply any control signal into inverter, please provide Vcc first. Please follow the reversed
sequence during power off. Power off control signal first, then power off Vcc.
TEST CIRCUIT :
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstraße 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 1.1.7, 31st August 2010
DC-AC INVERTER UNIT
PS-DA0143-01(S) (5 W SINGLE OUTPUT)
(PRELIMINARY INFORMATION)
ORDER KEY :
PS-DA0143-01-x
With order of this innverter please give the following key:
-x With Vrmt
-A: Without Vrmt by CN1 Pin5
Examples:
PS-DA0143-01 (S)
Inverter with Vrmt
PS-DA0143-01-A (S)
Inverter without Vrmt
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstraße 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (3)