DC-AC INVERTER UNIT - Power

DC-AC INVERTER UNIT
PS-M05D12-NJ4L-156(S) (6,5 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC/AC Inverter is developed for dual lamps.
Optimized for NEC: NL6448BC33-64
APPLICABLE LCD:
6.4 to 12 inches type double lamps
Lamp voltage 520 Vrms
Lamp current 5 mArms
Lamp Start Up Voltage 1.500 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
Ext. PWM dimming function
RoHS compliant (S)
The output capacitor and transformer bonding pins are
covered by special Varnish
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
LxWxH
105 ± 0.5
105 x 22,5 x 10mm
82 ± 0.3
13 ± 0.5
PS-MXXDXX-NJX
29/01/2004
MADE IN
GERMANY
CN1-1
CN2
(2)
CN1
15 ± 0.3
22,5 ± 0.5
5 ± 0.5
DIMENSIONS :
-10°C ~ +70°C
-20°C ~ +85°C
95 %RH max
CAUTION
HIGH VOLTAGE
CN2-1
CN1-5
10.0MAX
CN2-4
3
2 - Ø2.5 ± 0.2
(for M2 screws)
2
(2)
1
Unit : mm
Weight :20 (g) typ.
High Voltage generation area 60mm
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2
Input side CN1:
Pin No. Symbols
Vin
CN 1-1
GND
CN 1-2
CN 1-3 Ext. PWM
N.C.
CN 1-4
CN 1-5
Vrm t
Qty.
1
1
1
Ratings
12 Vdc
0 ~ 5 Vdc (L activ)
Material
UL94V-0 (FR-4 or CEM-3)
S5B-PH-SM3
SM04(4.0)B-BHS
Output side CN2:
Pin No. Symbols
Vhigh
CN 2-1
Vhigh
CN2-2
N.C.
CN 2-3
Vlow
CN 2-4
Note
t=1.6m m
JST or equal
JST or equal
Ratings
520 Vrm s (5 m Arm s )
520 Vrm s (5 m Arm s )
0 Vdc
0 / 5 Vdc (H activ)
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.3.1, 20th May 2014
DC-AC INVERTER UNIT
PS-M05D12-NJ4L-156(S) (6,5 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
Iout
Iout
Iin
F
Vopen
Conditions
Vrmt
Vin (V)
Tu (°C)
(V)
12±0.12 5±0.25 -10 ~ +70
12±1.2 5±0.25 -10 ~ +70
12±1.2 5±0.25 -10 ~ +70
12±1.2 5±0.25 -10 ~ +70
11,4
5±0.25 -10 ~ +70
Specification
Min.
Typ.
Max.
4.5
4.0
45
1.300
5.0
5.0
0.7
55
1.500
5.5
6.0
1.2
65
-
Unit
Note
m Arm s
m Arm s
Adc
kHz
Vrm s
Duty 100%
Note 1 :
Please keep a minimum of 2mm clearance in all directions between inverter high voltage areas
and any conductors.
Note 2:
PWM Disable (CN1-5) has priority over the Brightness PWM signal (CN1-3). When dimming via the
Brightness PWM signal (CN1-3) is requested, PWM Disable has to be set to L or left open.
Note 3:
The external PWM-frequency should be within the range of 100 ~ 500Hz. For other frequencies
please request. The optimum frequency is normally 250 Hz and this minimizes the interference
of the vertical sync frequency.
TEST CIRCUIT :
EXTERNAL PWM-DIMMING ( Remote ON / OFF Detailed Circuit Diagram ):
Backlight Mode
Full
bright
Dimming
support
OFF
PWM Disable
H
L
L
BRIGHTNESS
PWM
X
0%=full on
100%=full off
100%=H
(high Z)
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)