COA

File E193009
Vol. 2
Sec. 6
and Report
Page 1G
Issued:
Revised:
2002-02-07
2005-02-09
ELECTRICAL RATING:
Model
PFKC03-05S33Z-Z1Z1Z1
PFKC03-05S05Z-Z1Z1Z1
PFKC03-05S12Z-Z1Z1Z1
Input (dc)
V
4.5-6 or 5
4.5-6 or 5
4.5-6 or 5
Output(dc)
mA
mA
V
710
1010
926
3.3
5
12
600
600
250
File E193009
Vol. 2
Sec. 6
and Report
Page 2
Issued:
Revised:
2002-02-07
2005-02-09
ELECTRICAL RATING (CONTINUED):
Input (dc)
Output(dc)
mA
Model
V
mA
V
PFKC03-05S15Z-Z1Z1Z1
PFKC03-05D05Z-Z1Z1Z1
PFKC03-05D12Z-Z1Z1Z1
PFKC03-05D15Z-Z1Z1Z1
PFKC03-12S33Z-Z1Z1Z1
PFKC03-12S05Z-Z1Z1Z1
PFKC03-12S12Z-Z1Z1Z1
PFKC03-12S15Z-Z1Z1Z1
PFKC03-12D05Z-Z1Z1Z1
PFKC03-12D12Z-Z1Z1Z1
PFKC03-12D15Z-Z1Z1Z1
PFKC03-24S33Z-Z1Z1Z1
PFKC03-24S05Z-Z1Z1Z1
PFKC03-24S12Z-Z1Z1Z1
PFKC03-24S15Z-Z1Z1Z1
PFKC03-24D05Z-Z1Z1Z1
PFKC03-24D12Z-Z1Z1Z1
PFKC03-24D15Z-Z1Z1Z1
PFKC03-48S33Z-Z1Z1Z1
PFKC03-48S05Z-Z1Z1Z1
PFKC03-48S12Z-Z1Z1Z1
PFKC03-48S15Z-Z1Z1Z1
PFKC03-48D05Z-Z1Z1Z1
PFKC03-48D12Z-Z1Z1Z1
PFKC03-48D15Z-Z1Z1Z1
4.5-6 or 5
4.5-6 or 5
4.5-6 or 5
4.5-6 or 5
9-18 or 12
9-18 or 12
9-18 or 12
9-18 or 12
9-18 or 12
9-18 or 12
9-18 or 12
18-36 or 24
18-36 or 24
18-36 or 24
18-36 or 24
18-36 or 24
18-36 or 24
18-36 or 24
36-75 or 48
36-75 or 48
36-75 or 48
36-75 or 48
36-75 or 48
36-75 or 48
36-75 or 48
939
±966
±939
±966
334
470
445
457
±463
±450
±445
165
232
220
220
±228
±223
±223
81
118
112
112
±115
±112
±112
15
5
12
15
3.3
5
12
15
±5
±12
±15
3.3
5
12
15
±5
±12
±15
3.3
5
12
15
±5
±12
±15
200
±300
±125
±100
600
600
250
200
±300
±125
±100
600
600
250
200
±300
±125
±100
600
600
250
200
±300
±125
±100
File E193009
Vol. 2
Sec. 6
and Report
Page 4
Issued:
Revised:
2002-02-07
2005-02-09
Conditions of Acceptability - When installed in the end-product,
consideration shall be given to the following:
1.
This component has been judged on the basis of required spacing in the
Standard for Safety of Information Technology Equipment, CAN/CSA C22.2 No.
60950-1 and UL 60950-1 First Edition, dated April 1, 2003, Sub-clause 2.10,
which would cover the component itself if submitted for Listing.
2.
The products were tested on a 5 A time delay fuse protection circuit. If
used on a protection circuit greater than this, additional testing may be
necessary.
3.
All secondary output circuits are SELV and are not hazardous energy levels.
4.
The terminals and connectors are suitable for factory wiring only.
5.
The equipment has been evaluated for use in a Pollution Degree 2 environment.
6.
A suitable Electrical and Fire enclosure shall be provided.
7.
The component is intended to be connected to isolated secondary circuit which
is separated from primary circuit by Reinforced or Double insulation.
8.
All models withstood 3200 V dc Electric Strength Test.