COA

ELECTRICAL RATING:
Input (dc)
Model
FKC12-12S2P5- z1z1z1z1z1z1
FKC12-12S3P3- z1z1z1z1z1z1
FKC12-12S05- z1z1z1z1z1z1
FKC12-12S12- z1z1z1z1z1z1
FKC12-12S15- z1z1z1z1z1z1
FKC12-12D05- z1z1z1z1z1z1
FKC12-12D12- z1z1z1z1z1z1
FKC12-12D15- z1z1z1z1z1z1
FKC12-24S2P5- z1z1z1z1z1z1
FKC12-24S3P3- z1z1z1z1z1z1
FKC12-24S05- z1z1z1z1z1z1
FKC12-24S12- z1z1z1z1z1z1
FKC12-24S15- z1z1z1z1z1z1
FKC12-24D05- z1z1z1z1z1z1
FKC12-24D12- z1z1z1z1z1z1
FKC12-24D15- z1z1z1z1z1z1
FKC12-48S2P5- z1z1z1z1z1z1
FKC12-48S3P3- z1z1z1z1z1z1
FKC12-48S05- z1z1z1z1z1z1
FKC12-48S12- z1z1z1z1z1z1
FKC12-48S15- z1z1z1z1z1z1
FKC12-48D05- z1z1z1z1z1z1
FKC12-48D12- z1z1z1z1z1z1
FKC12-48D15- z1z1z1z1z1z1
V
mA
9 ~18 or 12
9 ~ 18 or 12
9 ~ 18 or 12
9 ~ 18 or 12
9 ~ 18 or 12
9 ~ 18 or 12
9 ~ 18 or 12
9 ~ 18 or 12
18 ~ 36 or 24
18 ~ 36 or 24
18 ~ 36 or 24
18 ~ 36 or 24
18 ~ 36 or 24
18 ~ 36 or 24
18 ~ 36 or 24
18 ~ 36 or 24
36 ~ 75 or 48
36 ~ 75 or 48
36 ~ 75 or 48
36 ~ 75 or 48
36 ~ 75 or 48
36 ~ 75 or 48
36 ~ 75 or 48
36 ~ 75 or 48
1314
1688
1743
1708
1708
1801
1688
1688
647
833
860
843
843
889
832
832
324
416
430
421
421
443
415
415
V
2.5
3.3
5.1
12
15
±5
± 12
± 15
2.5
3.3
5.1
12
15
±5
± 12
± 15
2.5
3.3
5.1
12
15
±5
± 12
± 15
Output(dc)
mA
3500
3500
2400
1000
800
± 1200
± 500
± 400
3500
3500
2400
1000
800
± 1200
± 500
± 400
3500
3500
2400
1000
800
± 1200
± 500
± 400
File E193009
Vol. 2
Sec. 5
and Report
Page 5
Issued:
Revised:
2002-01-17
2013-03-05
ENGINEERING CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE'S USE):
Use - For use only in complete equipment where the acceptability of the combination is
determined by Underwriters Laboratories Inc.
Special Considerations - The following items are considerations that were used when
evaluating this product.
*USR/CNR indicates investigation to the U.S. and Canadian (Bi-National) Standard for Safety
of Information Technology Equipment, UL 60950-1, 2nd Edition, 2011-12-19 (Information
Technology Equipment - Safety - Part 1: General Requirements)
CSA C22.2 No. 60950-1-07, 2nd Edition, 2011-12 (Information Technology Equipment - Safety
- Part 1: General Requirements).
The component was submitted and tested for a maximum manufacturer’s recommended
ambient (Tma) of 55°C.
Conditions of Acceptability - When installed in the end-product, consideration shall be given
to the following:
*1.
This component has been judged on the basis of required spacing in the Standard for Safety
of Information Technology Equipment, UL 60950-1, 2nd Edition, 2011-12-19
(Information Technology Equipment - Safety - Part 1: General Requirements) CSA
C22.2 No. 60950-1-07, 2nd Edition, 2011-12 (Information Technology Equipment Safety - Part 1: General Requirements), which would cover the component itself if
submitted for Listing.
2.
The products were tested on a 6.3A time delay fuse protection circuit. If used on a
protection circuit greater than this, additional testing may be necessary.
3.
All secondary output circuits are SELV and are not hazardous energy levels.
4.
5.
6.
The terminals and connectors are suitable for factory wiring only.
The equipment has been evaluated for use in a Pollution Degree 2 environment.
A suitable Electrical and Fire enclosure shall be provided.
7.
The component is intended to be connected to isolated secondary circuit which is separated
from primary circuit by Reinforced or Double insulation.
8.
PWB shall not exceed 105°C during heating test end-product installation.
9.
The product was investigated for functional insulation and complies with 2.2.4 under single
fault conditions.