File E193009 Vol. 2 Sec. 8 and Report Page 1 Issued: Revised: 2002-04-11 2005-03-11 DESCRIPTION PRODUCT COVERED: USR/CNR DC-DC Converter, FECX-X1X2X3 where X can be 40; X1 can be 24 or 48; X2 can be S or T; X3 can be 1P8, 2P5, 3P3, 05, 12, 15, 0512, 0515, 3312 or 3315. ELECTRICAL RATING: Input (dc) V Model FEC40-12S1P5 FEC40-12S1P8 FEC40-12S2P5 FEC40-12S3P3 FEC40-12S05 FEC40-12S12 FEC40-12S15 FEC40-12D12 FEC40-12D15 FEC40-12D3305 FEC40-12T3312 9-18 9-18 9-18 9-18 9-18 9-18 9-18 9-18 9-18 9-18 9-18 or or or or or or or or or or or 12 12 12 12 12 12 12 12 12 12 12 A 1.754 2.162 2.924 3.761 5.698 5.697 5.624 6.234 6.061 4.791 4.298 Output (dc) V A 1.5 1.8 2.5 3.3 5 12 15 ±12 ±15 3.3/5 3.3/±12 8 8 8 8 8 3.333 2.666 ±1.8 ±1.4 4/4 6/±0.4 File E193009 Vol. 2 Sec. 8 and Report Page 1A FEC40-12T3315 FEC40-12T0512 FEC40-12T0515 FEC40-24S1P5 FEC40-24S1P8 FEC40-24S2P5 FEC40-24S3P3 FEC40-24S05 FEC40-24S12 FEC40-24S15 FEC40-24D12 FEC40-24D15 FEC40-24D3305 FEC40-24T3312 9-18 or 12 9-18 or 12 9-18 or 12 18-36 or 24 18-36 or 24 18-36 or 24 18-36 or 24 18-36 or 24 18-36 or 24 18-36 or 24 18-36 or 24 18-36 or 24 18-36 or 24 18-36 or 24 4.211 5.641 5.556 0.913 1.067 1.425 1.857 2.743 2.778 2.743 3.038 2.954 2.365 2.121 FEC40-24T3315 18-36 or 24 2.078 FEC40-24T0512 18-36 or 24 2.785 FEC40-24T0515 18-36 or 24 2.743 FEC40-48S1P5 FEC40-48S1P8 FEC40-48S2P5 FEC40-48S3P3 FEC40-48S05 FEC40-48S12 FEC40-48S15 FEC40-48D12 FEC40-48D15 FEC40-48D3305 FEC40-48T3312 36-75 36-75 36-75 36-75 36-75 36-75 36-75 36-75 36-75 36-75 36-75 48 48 48 48 48 48 48 48 48 48 48 0.45 0.526 0.712 0.917 1.355 1.372 1.371 1.519 1.477 1.153 1.047 FEC40-48T3315 36-75 or 48 1.026 FEC40-48T0512 36-75 or 48 1.375 FEC40-48T0515 36-75 or 48 1.354 or or or or or or or or or or or Issued: New: 3.3/±15 5/±12 5/±15 1.5 1.8 2.5 3.3 5 12 15 ±12 ±15 3.3/5 3.3 ±12 3.3 ±15 5 ±12 5 ±15 1.5 1.8 2.5 3.3 5 12 15 ±12 ±15 3.3/5 3.3 ±12 3.3 ±15 5 ±12 5 ±15 2002-04-11 2005-03-11 6/±0.3 6/±0.4 6/±0.3 8 8 8 8 8 3.33 2.66 ±1.8 ±1.4 4/4 6 ±0.4 6 ±0.3 6 ±0.4 6 ±0.3 8 8 8 8 8 3.33 2.66 ±1.8 ±1.4 4/4 6 ±0.4 6 ±0.3 6 ±0.4 6 ±0.3 File E193009 Vol. 2 Sec. 8 and Report Page 2 Issued: Revised: 2002-04-11 2005-03-11 Conditions of Acceptability - When installed in the end-product, consideration shall be given to the following: 1. This component has been judged on the basis of the required spacings in the Standard for Safety of Information Technology Equipment, Including Electrical Business Equipment, CAN/CSA C22.2 No. 60950-1 and UL 60950-1 First Edition, dated April 1, 2003. 2. The products were tested on a 5 A time delay fuse protection circuit. If used on a protection circuit greater than this, additional testing may be necessary. 3. All secondary output circuits are SELV and are not hazardous energylevels. 4. The terminals and connectors are suitable for factory wiring only. 5. The equipment has been evaluated for use in a Pollution Degree 2 environment. 6. A suitable Electrical and Fire enclosure shall be provided. 7. The component is intended to be connected to isolated secondary circuit which is separated from primary circuit by Reinforced or Double insulation. 8. If the input meets all the requirements for ELV, then the output may be considered ELV. 9. If the input meets all the requirements for SELV: (Voltage less than 60Vdc), the output may be considered SELV. Output voltage remains within SELV. Single component Failure and Operational Insulation by pass Tests were performed in the Power Converters.