COA

File E193009
Vol. 2
Sec. 8
and Report
Page 1
Issued:
Revised:
2002-04-11
2005-03-11
DESCRIPTION
PRODUCT COVERED:
USR/CNR DC-DC Converter, FECX-X1X2X3 where X can be 40; X1 can be 24 or
48; X2 can be S or T; X3 can be 1P8, 2P5, 3P3, 05, 12, 15, 0512, 0515, 3312 or
3315.
ELECTRICAL RATING:
Input (dc)
V
Model
FEC40-12S1P5
FEC40-12S1P8
FEC40-12S2P5
FEC40-12S3P3
FEC40-12S05
FEC40-12S12
FEC40-12S15
FEC40-12D12
FEC40-12D15
FEC40-12D3305
FEC40-12T3312
9-18
9-18
9-18
9-18
9-18
9-18
9-18
9-18
9-18
9-18
9-18
or
or
or
or
or
or
or
or
or
or
or
12
12
12
12
12
12
12
12
12
12
12
A
1.754
2.162
2.924
3.761
5.698
5.697
5.624
6.234
6.061
4.791
4.298
Output (dc)
V
A
1.5
1.8
2.5
3.3
5
12
15
±12
±15
3.3/5
3.3/±12
8
8
8
8
8
3.333
2.666
±1.8
±1.4
4/4
6/±0.4
File E193009
Vol. 2
Sec. 8
and Report
Page 1A
FEC40-12T3315
FEC40-12T0512
FEC40-12T0515
FEC40-24S1P5
FEC40-24S1P8
FEC40-24S2P5
FEC40-24S3P3
FEC40-24S05
FEC40-24S12
FEC40-24S15
FEC40-24D12
FEC40-24D15
FEC40-24D3305
FEC40-24T3312
9-18 or 12
9-18 or 12
9-18 or 12
18-36 or 24
18-36 or 24
18-36 or 24
18-36 or 24
18-36 or 24
18-36 or 24
18-36 or 24
18-36 or 24
18-36 or 24
18-36 or 24
18-36 or 24
4.211
5.641
5.556
0.913
1.067
1.425
1.857
2.743
2.778
2.743
3.038
2.954
2.365
2.121
FEC40-24T3315
18-36 or 24
2.078
FEC40-24T0512
18-36 or 24
2.785
FEC40-24T0515
18-36 or 24
2.743
FEC40-48S1P5
FEC40-48S1P8
FEC40-48S2P5
FEC40-48S3P3
FEC40-48S05
FEC40-48S12
FEC40-48S15
FEC40-48D12
FEC40-48D15
FEC40-48D3305
FEC40-48T3312
36-75
36-75
36-75
36-75
36-75
36-75
36-75
36-75
36-75
36-75
36-75
48
48
48
48
48
48
48
48
48
48
48
0.45
0.526
0.712
0.917
1.355
1.372
1.371
1.519
1.477
1.153
1.047
FEC40-48T3315
36-75 or 48
1.026
FEC40-48T0512
36-75 or 48
1.375
FEC40-48T0515
36-75 or 48
1.354
or
or
or
or
or
or
or
or
or
or
or
Issued:
New:
3.3/±15
5/±12
5/±15
1.5
1.8
2.5
3.3
5
12
15
±12
±15
3.3/5
3.3
±12
3.3
±15
5
±12
5
±15
1.5
1.8
2.5
3.3
5
12
15
±12
±15
3.3/5
3.3
±12
3.3
±15
5
±12
5
±15
2002-04-11
2005-03-11
6/±0.3
6/±0.4
6/±0.3
8
8
8
8
8
3.33
2.66
±1.8
±1.4
4/4
6
±0.4
6
±0.3
6
±0.4
6
±0.3
8
8
8
8
8
3.33
2.66
±1.8
±1.4
4/4
6
±0.4
6
±0.3
6
±0.4
6
±0.3
File E193009
Vol. 2
Sec. 8
and Report
Page 2
Issued:
Revised:
2002-04-11
2005-03-11
Conditions of Acceptability - When installed in the end-product,
consideration shall be given to the following:
1.
This component has been judged on the basis of the required
spacings in the Standard for Safety of Information Technology
Equipment, Including Electrical Business Equipment,
CAN/CSA
C22.2 No. 60950-1 and UL 60950-1 First Edition, dated April 1,
2003.
2.
The products were tested on a 5 A time delay fuse protection
circuit. If used on a protection circuit greater than this,
additional testing may be necessary.
3.
All secondary output circuits are SELV and are not hazardous
energylevels.
4.
The terminals and connectors are suitable for factory wiring only.
5.
The equipment has been evaluated for use in a Pollution Degree 2
environment.
6.
A suitable Electrical and Fire enclosure shall be provided.
7.
The component is intended to be connected to isolated secondary
circuit which is separated from primary circuit by Reinforced or
Double insulation.
8.
If the input meets all the requirements for ELV, then the output
may be considered ELV.
9.
If the input meets all the requirements for SELV: (Voltage less
than 60Vdc), the output may be considered SELV. Output voltage
remains within SELV. Single component Failure and Operational
Insulation by pass Tests were performed in the Power Converters.