NEC Express5800/T110f-S System Configuration Guide Liquid cooling model Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC Express5800 server. January 16, 2014 Revision 3.0 NEC Corporation SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model Contents TECHNICAL SPECIFICATION ........................................................................................ 3 Key Features .......................................................................................................................................... 3 Specification .......................................................................................................................................... 3 EXTERNAL VIEWS ......................................................................................................... 7 Front View .............................................................................................................................................. 7 Rear Views ............................................................................................................................................. 7 Dimensions (mm) .................................................................................................................................. 8 CONFIGURATION DIAGRAM ....................................................................................... 10 Expansion Slots .................................................................................................................................. 11 SERVER CONFIGURATION ......................................................................................... 12 1 2 3 4 5 6 7 8 9 Base Models ................................................................................................................................. 12 Processor ..................................................................................................................................... 12 Memory ......................................................................................................................................... 12 Internal Hard Disk Drives ............................................................................................................ 14 4.1 RAID Configuration .............................................................................................................. 14 4.2 2.5-inch Drive Configuration ................................................................................................ 16 4.3 3.5-inch Drive Configuration ................................................................................................ 26 Internal Optical Drive ................................................................................................................... 30 Internal RDX Drive ....................................................................................................................... 30 PCI Card ........................................................................................................................................ 30 7.1 Network Interface Controller ................................................................................................ 30 7.2 SAS Controller ..................................................................................................................... 31 7.3 Serial Port Adapter .............................................................................................................. 31 Other Add-in Components .......................................................................................................... 32 8.1 Trusted Platform Module Kit ................................................................................................ 32 8.2 Internal Flash Memory ......................................................................................................... 32 8.3 Flash FDD............................................................................................................................ 32 8.4 Input Devices ....................................................................................................................... 32 Add-on Components ................................................................................................................... 33 9.1 Server Management License............................................................................................... 33 9.2 Rack Conversion Kit ............................................................................................................ 33 9.3 Dust Proof Kit ...................................................................................................................... 33 9.4 Tamper Proof Power Button Covers .................................................................................... 33 9.5 Medium and Cartridge ......................................................................................................... 34 REFERENCES............................................................................................................... 35 Server Management ............................................................................................................................ 35 OS Support Matrix for PCI Cards and Embedded Controllers ....................................................... 36 Supported PCI cards and Installable Slots....................................................................................... 36 Copyright Notice and Liability Disclaimer ........................................................................................ 37 REVISION HISTORY ..................................................................................................... 38 NEC Corporation Revision 3.0 – January 16, 2014 2 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model Technical Specification Key Features Ultra compact form of 93mm in width, 13 liters in volume Up to 32 GB of high speed DDR3-1600 memory Full manageability by integrated EXPRESSSCOPE Engine 3 Function in maximum 40° C / 104° F ambient temperature Specification (1 / 2) Model T110f-S Part Number Processor N8100-1984F Type Intel® Core™ i3-4330 processor Intel® Xeon® processor E3-1220 v3 Intel® Xeon® processor E3-1230L v3 Clock speed 3.50 GHz 3.10 GHz 1.80 GHz Number of Processors 1 Cache 4 MB 8MB Cores and Threads 2C / 4T 4C / 4T Chipset Memory Internal Storage Intel® C224 Chipset Type DDR3-1600 ECC Unbuffered DIMM Standard Capacity 0 GB Maximum Capacity 32 GB (4 x 8 GB) Standard Capacity 0 GB Maximum Capacity 8 TB (2 x 4 TB) Disk Controller SATA : 6Gb/s (Integrated) RAID SATA : RAID 0/1/10 (Standard), RAID 5/6/50/60 (Optional) SAS : RAID 0/1/5/6/10/50/60 (Optional) Hot Plug Supported (When using N8154-59F or N8154-59F/-56F) Optical Disk Drive Optional 3.5-inch Media Bays 1 Disk Drive Bays 2 or 4 or 6 Expansion Slots Video 4C / 8T Total: 4 slots available 1 PCIe 3.0 x16 (x16 connector) 1 PCIe 2.0 x4 (x8 connector) 2 PCIe 2.0 x1 (x8 connector) Controller (VRAM) Integrated in Server Management Controller (32MB) Resolution / Color 1280 x 1024 / 16.7M 2 Interfaces 1 VGA (15-pin mini D-sub,1 rear) 1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear) 4 USB3.0 (1 front, 2 rear, 1 internal) 4 USB2.0 (1 front, 2 rear, 1 internal) 2 1000BASE-T LAN connector (RJ-45, 2 rear) 1 100BASE-TX LAN connector for Management (RJ-45, 1 rear) Server Management EXPRESSSCOPE Engine 3 System Fan Standard NEC Corporation Revision 3.0 – January 16, 2014 3 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model Model T110f-S Power Supply 1 x 250 Watt 80 PLUS® Platinum certified non-Hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz Power Consumption (Max. Config, Idling) (Max. Config, Operating) Minimum Config. 1 2 3 4 5 6 114 VA / 97 Watt 192 VA / 180 Watt 206 VA / 192 Watt 156 VA / 144 Watt Acoustic Noise (Sound Pressure Maximum Config. 3 Level) Dimensions (W x D x H ) 28.9 dB 32.2 dB 29.1 dB 37.9 dB 38.2 dB 38.1 dB Weight (Minimum / Maximum) 8 kg / 11 kg, 17.64 lbs. / 24.25 lbs. Temperature, Relative Humidity (non-condensing) Operating: 10° to 40° C / 50° to 104° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% Regulatory and Safety FCC, CE, UL, CB, RoHS, BSMI, CCC, RCM, WEEE Operating Systems and Virtualization Software Microsoft® Windows Server® 2008 x86 Standard Microsoft® Windows Server® 2008 x86 Enterprise Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter 4 Microsoft® Windows Server® 2012 R2 Standard 4 Microsoft® Windows Server® 2012 R2 Datacenter 5 Red Hat Enterprise Linux 5.9 or later 5 Red Hat Enterprise Linux 5.9 or later (EM64T) 5 Red Hat Enterprise Linux 6.4 or later 5 Red Hat Enterprise Linux 6.4 or later (EM64T) 6 VMware ESXi™ 5.1 Update 1 6 VMware ESXi™ 5.5 98.0 x 386.5 x 341.0 mm / 3.9 x 15.2 x 13.4 in Embedded SATA RAID controller is supported only on Windows operating systems. Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. Noise emission was measured in accordance with ISO 7779. The actual value may vary by the operating environment. For Windows Server 2012 R2 installation, download the driver kit from the following website and install it after OS installation http://www.nec.com/en/global/prod/express/download/ For Linux support, contact your sales representative or go to the NEC website at: http://www.nec.com/global/prod/express/linux/index.html Support on Xeon and Core processor systems only. (2 / 2) Model T110f-S Part Number N8100-1984F Processor Chipset NEC Corporation Type Intel® Xeon® processor E3-1265L v3 Intel® Xeon® processor E3-1230 v3 Intel® Xeon® processor E3-1270 v3 Clock speed 2.50 GHz 3.30 GHz 3.50GHz Number of Processors 1 Cache 8MB Cores and Threads 4C / 8T 4C / 8T Intel® C224 Chipset Revision 3.0 – January 16, 2014 4 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model Model Memory Internal Storage T110f-S Type DDR3-1600 ECC Unbuffered DIMM Standard Capacity 0 GB Maximum Capacity 32 GB (4 x 8 GB) Standard Capacity 0 GB Maximum Capacity 8 TB (2 x 4 TB) Disk Controller SATA : 6Gb/s (Integrated) RAID SATA : RAID 0/1/10 (Standard), RAID 5/6/50/60 (Optional) SAS : RAID 0/1/5/6/10/50/60 (Optional) Hot Plug Supported (When using N8154-59F or N8154-59F/-56F) Optical Disk Drive Optional 3.5-inch Media Bays 1 Disk Drive Bays 2 or 4 or 6 Expansion Slots Video Total: 4 slots available 1 PCIe 3.0 x16 (x16 connector) 1 PCIe 2.0 x4 (x8 connector) 2 PCIe 2.0 x1 (x8 connector) Controller (VRAM) Integrated in Server Management Controller (32MB) Resolution / Color 1280 x 1024 / 16.7M 2 Interfaces 1 VGA (15-pin mini D-sub,1 rear) 1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear) 4 USB3.0 (1 front, 2 rear, 1 internal) 4 USB2.0 (1 front, 2 rear, 1 internal) 2 1000BASE-T LAN connector (RJ-45, 2 rear) 1 100BASE-TX LAN connector for Management (RJ-45, 1 rear) Server Management EXPRESSSCOPE Engine 3 System Fan Standard Power Supply 1 x 250 Watt 80 PLUS® Platinum certified non-Hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz Power Consumption (Max. Config, Idling) 113 VA / 96 Watt 112 VA / 98 Watt (Max. Config, Operating) Minimum Config. 183 VA / 170 Watt 219 VA / 207 Watt Acoustic Noise (Sound Pressure Maximum Config. 3 Level) Dimensions (W x D x H ) 29.1 dB 32.2 dB 38.1 dB 38.2 dB Weight (Minimum / Maximum) 8 kg / 11 kg, 17.64 lbs. / 24.25 lbs. Temperature, Relative Humidity (non-condensing) Operating: 10° to 40° C / 50° to 104° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% Regulatory and Safety FCC, CE, UL, CB, RoHS, BSMI, CCC, RCM, WEEE Operating Systems and Virtualization Software Microsoft® Windows Server® 2008 x86 Standard Microsoft® Windows Server® 2008 x86 Enterprise Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter 4 Microsoft® Windows Server® 2012 R2 Standard 4 Microsoft® Windows Server® 2012 R2 Datacenter 5 Red Hat Enterprise Linux 5.9 or later 5 Red Hat Enterprise Linux 5.9 or later (EM64T) 5 Red Hat Enterprise Linux 6.4 or later NEC Corporation 220 VA / 208 Watt 98.0 x 386.5 x 341.0 mm / 3.9 x 15.2 x 13.4 in Revision 3.0 – January 16, 2014 5 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model Red Hat Enterprise Linux 6.4 or later (EM64T) 5 VMware ESXi™ 5.1 Update 1 VMware ESXi™ 5.5 1 2 3 4 5 Embedded SATA RAID controller is supported only on Windows operating systems. Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. Noise emission was measured in accordance with ISO 7779. The actual value may vary by the operating environment. For Windows Server 2012 R2 installation, download the driver kit from the following website and install it after OS installation http://www.nec.com/en/global/prod/express/download/ For Linux support, contact your sales representative or go to the NEC website at: http://www.nec.com/global/prod/express/linux/index.html NEC Corporation Revision 3.0 – January 16, 2014 6 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model External Views Front View A B C D E F G H I J Legend A. Power Button F. USB 2.0 Connectors B. Power LED G. Optical Disk Drive C. Drive Activity LED H. 3.5-inch Media Bay D. System Status LED I. Drive Bay Cover Key E. USB 3.0 Connectors K. Drive Bay Cover Rear Views A J B C D E F G H I Legend A. Serial Port (A) Connector F. USB 3.0 Connector B. VGA Connector G. Management LAN Connector C. BMC Reset Switch H. Data LAN Connectors D. Dump (NMI) Switch I. PCI Slots (Low Profile) E. USB 2.0 Connector J AC Inlet NEC Corporation Revision 3.0 – January 16, 2014 7 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model Dimensions (mm) Standard Bezel Tower Orientation Desktop Orientation NEC Corporation Revision 3.0 – January 16, 2014 8 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model Dust Proof Bezel Tower Orientation Desktop Orientation NEC Corporation Revision 3.0 – January 16, 2014 9 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model Configuration Diagram Legend: NEC Corporation Minimum requirement components Revision 3.0 – January 16, 2014 Standard components 10 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model Expansion Slots #1 #2 #3 #4 Legend #1 PCIe 2.0 x1, x8 connector, Low Profile, up to 168mm length #2 PCIe 2.0 x1, x8 connector, Low Profile, up to 168mm length #3 PCIe 3.0 x16, x16 connector, Low Profile, up to 168mm length #4 PCIe 2.0 x4, x8 connector, Low Profile, up to 168mm length NEC Corporation Revision 3.0 – January 16, 2014 11 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model Server Configuration 1 Base Models Product Name / Description Part Number NEC Express5800/T110f-S no Processor, no RAM, no Drive Cage, no HDD, no Optical Drive Including: 250 Watt non-hot plug power supply, EXPRESSBUILDER DVD N8100-1984F 2 Processor Available sockets: 1 Category Product Name / Description Part Number Processors Required Core i3-4330 Processor Kit Intel® Core™ i3-4330 Processor (3.50 GHz, 2C/4T, 4 MB) Xeon E3-1220 v3 Processor Kit Intel® Xeon ® Processor E3-1220 v3 (3.10 GHz, 4C/4T, 8 MB) Xeon E3-1230L v3 Processor Kit Intel® Xeon ® Processor E3-1230L v3 (1.80 GHz, 4C/8T, 8 MB) Xeon E3-1230 v3 Processor Kit Intel® Xeon ® Processor E3-1230 v3 (3.30 GHz, 4C/8T, 8 MB) Xeon E3-1265L v3 Processor Kit Intel® Xeon ® Processor E3-1265L v3 (2.50 GHz, 4C/8T, 8 MB) Xeon E3-1270 v3 Processor Kit Intel® Xeon ® Processor E3-1270 v3 (3.50 GHz, 4C/8T, 8 MB) N8101-624F N8101-626F N8101-627F N8101-628F N8101-629F N8101-639F NOTE: One processor kit from above must be installed. VMware ESXi is not supported on Pentium processor systems. 3 Memory Available slots: 4 Product Name / Description Part Number 2GB DDR3-1600 UNB Memory Kit 2GB Unbuffered ECC DIMM, DDR3L-1600(PC3-12800) 4GB DDR3-1600 UNB Memory Kit 4GB Unbuffered ECC DIMM, DDR3L-1600(PC3-12800) 8GB DDR3-1600 UNB Memory Kit 8GB Unbuffered ECC DIMM, DDR3L-1600(PC3-12800) N8102-523F N8102-524F N8102-525F NOTE: Minimum one memory kit must be installed. To install by double of memory kit is recommended in order to increase memory transfer speed by dual-channel symmetric configuration. Actual memory speed drops to 1333 MHz when you choose Pentium Processor. NEC Corporation Revision 3.0 – January 16, 2014 12 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model Maximum Available Memory See the table below for the maximum memory size that you can actually use on your system. The maximum available memory is less than the maximum physical memory supported by your system because some chipsets require PCI resource space of about 750MB. PCI resource requirements vary depending on the type and the number of PCI cards you are using. Maximum Memory Size Supported by Operating Systems 4 GB 4 GB( HW-DEP enabled) App. 3.5 GB (HW-DEP disabled) 32 GB 32 GB 64 GB 32 GB 1 2 TB 32 GB Microsoft Windows Server 2012 Standard 1 Microsoft Windows Server 2012 Datacenter 1 Microsoft Windows Server 2012 R2 Standard 1 Microsoft Windows Server 2012 R2 Datacenter 4 TB 32 GB Red Hat Enterprise Linux 5 Red Hat Enterprise Linux 6 16 GB 16 GB Red Hat Enterprise Linux 5 (EM64T) 1 TB 32 GB Red Hat Enterprise Linux 6 (x86_64) 3 TB 32 GB VMware ESXi 5.1 2 2 TB 32 GB VMware ESXi 5.5 2 4 TB 32 GB Microsoft Windows Server 2008 Standard Microsoft Windows Server 2008 R2 Standard 1 Microsoft Windows Server 2008 Enterprise Microsoft Windows Server 2008 R2 Enterprise 1 1 2 3 Maximum Available Memory The maximum available memory size of Hyper-V systems are below: - Windows Server 2008 R2 Standard : 32 GB - Windows Server 2008 R2 Enterprise : 1TB - Windows Server 2012, Windows Server 2012 R2 : 4 TB Up to 1TB of main memory is available to each virtual machine. Up to 1TB of main memory is available to each virtual machine. NEC Corporation Revision 3.0 – January 16, 2014 13 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model 4 Internal Hard Disk Drives 4.1 RAID Configuration Refer to the section in accordance with your disk form factor and RAID configuration 4.1.1 2.5-inch Drive Up to four Drives Available Interface Refer to 4.2.1 SATA Refer to 4.2.2 SATA 0 MB Cache Refer to 4.2.3 SAS, SATA 512 MB Cache Refer to 4.2.4 SAS, SATA 512 MB Cache Refer to 4.2.5 SAS, SATA 1GB Cache / Battery Refer to 4.2.6 SAS, SATA 1GB Cache / CacheVault Refer to 4.2.7 SAS, SATA Non-RAID Embedded SATA RAID Controller RAID 0/1 Optional RAID Controller RAID 5 Up to six Drives Available Interface RAID 0/1 RAID 5/6 0MB Cache Refer to 4.2.8 SAS, SATA 512 MB Cache Refer to 4.2.9 SAS, SATA 512 MB Cache Refer to 4.2.10 SAS, SATA 1GB Cache / Battery Refer to 4.2.11 SAS, SATA 1GB Cache / CacheVault Refer to 4.2.12 SAS, SATA NOTE: No tape drive can be installed when installing an optional 2.5-inch drive cage. Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller. Embedded SATA RAID controller is supported only on Windows operating systems. An optional RAID controller is required to configure RAID array for other operating systems. Up to two kinds of drives can be mixed in a system. All drives within a RAID array should be of the same capacity and rotation speed. Mixing SAS and SATA hard drives in the same drive cage is not supported. All drives within a drive cage should be of the same rotation speed. NEC Corporation Revision 3.0 – January 16, 2014 14 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model 4.1.2 3.5-inch Drive Up to two 3.5-inch Drives Available Interface Refer to 4.3.1 SATA Refer to 4.3.2 SATA 0 MB Cache Refer to 4.3.3 SATA 512 MB Cache Refer to 4.3.4 SATA Non-RAID Embedded SATA RAID Controller RAID 0/1 Optional RAID Controller Up to two 3.5-inch Drives plus two 2.5-inch Drives Available Interface RAID 0/1 Refer to 4.3.5 SATA, SAS NOTE: No tape drive can be installed when installing an optional 2.5-inch drive cage. Hot plug insertion/removal is not supported on the 3.5-inch drive configuration. Embedded SATA RAID controller is supported only on Windows operating systems. An optional RAID controller is required to configure RAID array for other operating systems. All hard drives within a RAID array should be of the same capacity and rotation speed. All drives within a RAID array should be of the same capacity and rotation speed. NEC Corporation Revision 3.0 – January 16, 2014 15 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model 4.2 2.5-inch Drive Configuration 4.2.1 Up to four Drives with Embedded SATA Controller Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 4x 6Gb/s SATA Internal SATA Cable Mini-SAS to mini-SAS 2.5-inch Drive Cage 4 x 2.5-inch hot plug drive bays 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm (Standard) Cable Drive Cage Required Drive 4 slots available SATA HDD (Standard) N8154-59F N8150-356 N8150-357 N8150-358 NOTE Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller. 4.2.2 Up to four Drives with Embedded SATA RAID Controller Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 4x 6Gb/s SATA, RAID0/1/10 capable Internal SATA Cable miniSAS to miniSAS 2.5-inch Drive Cage 4 x 2.5-inch hot plug drive bays 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm (Standard) Cable Drive Cage Required Drive 3 slots available SATA (Standard) N8154-59F N8150-356 N8150-357 N8150-358 NOTE Embedded SATA RAID controller is supported only on Windows operating systems. An optional RAID controller is required to configure RAID array for other operating systems. All hard drives within a RAID array should be of the same capacity and rotation speed. NEC Corporation Revision 3.0 – January 16, 2014 16 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model 4.2.3 Up to four Drives with RAID 0/1 Controller with 0 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (0MB, RAID 0/1) LSI MegaRAID SAS 9240-8i RAID0/1/10, 0MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s Internal SATA Cable Mini-SAS to mini-SAS 2.5-inch Drive Cage 4 x 2.5-inch hot plug drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm N8103-171 Cable Drive Cage Required Drive 4 slots available SAS HDD SATA HDD (Standard) N8154-59F N8150-301 N8150-322 N8150-304 N8150-332 N8150-408 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed.. NEC Corporation Revision 3.0 – January 16, 2014 17 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model 4.2.4 Up to four Drives with RAID 0/1 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID 0/1) LSI MegaRAID SAS 9267-8i RAID0/1/10, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i Internal SAS/SATA Cable Mini-SAS to mini-SAS 2.5-inch Drive Cage 4 x 2.5-inch hot plug drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s N8103-149 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s N8150-712 RAID BBU Recommended Cable Drive Cage Required Drive 3 slots available SAS HDD SATA HDD SAS SSD N8103-155 (Standard) N8154-59F N8150-301 N8150-322 N8150-304 N8150-332 N8150-408 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 3.0 – January 16, 2014 18 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model 4.2.5 Up to four Drives with RAID 5/6 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID 0/1/5/6) LSI MegaRAID SAS 9267-8i RAID0/1/5/6/10/50/60, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i Internal SAS/SATA Cable Mini-SAS to mini-SAS 2.5-inch Drive Cage 4 x 2.5-inch hot plug drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s N8103-150 RAID BBU Recommended Cable Drive Cage Required Drive 4 slots available SAS HDD SATA HDD SAS SSD N8103-155 (Standard) N8154-59F N8150-301 N8150-322 N8150-304 N8150-332 N8150-408 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 3.0 – January 16, 2014 19 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model 4.2.6 Up to four Drives with RAID 5 Controller with 1 GB Cache/Battery Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID0/1/5/6) LSI MegaRAID SAS 9267-8i RAID0/1/5/6/10/50/60, 1 GB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i MegaRAID CacheCade for LSI MegaRAID SAS NOTE: - SSD used for cache is required - The SSD capacity which can be used as read cache is up to 512 GB. N8103-151 Internal SAS/SATA Cable Mini-SAS to mini-SAS 2.5-inch Drive Cage 4 x 2.5-inch hot plug drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s (Standard) RAID BBU Recommended SSD Caching Recommended Cable Drive Cage Required Drive 4 slots available SAS HDD SATA HDD SAS SSD N8103-155 N8103-156 N8154-59F N8150-301 N8150-322 N8150-304 N8150-332 N8150-408 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed.. NEC Corporation Revision 3.0 – January 16, 2014 20 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model 4.2.7 Up to four Drives with RAID 5 Controller with 1 GB Cache/CacheVault Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) LSI MegaRAID SAS 9270CV-8i (with CV) RAID0/1/5/6/10/50/60, 1GB Cache, Int. 8ports, PCIe 3.0(x8), 6Gb/s, flash cache protection modules included MegaRAID CacheCade for LSI MegaRAID SAS NOTE: - SSD used for cache is required - The SSD capacity which can be used as read cache is up to 512 GB. N8103-167 Internal SATA Cable Mini-SAS to mini-SAS 2.5-inch Drive Cage 4 x 2.5-inch hot plug drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s (Standard) SSD Caching Recommended Cable Drive Cage Required Drive 4 slots available SAS HDD SATA HDD SAS SSD N8103-156 N8154-59F N8150-301 N8150-322 N8150-304 N8150-332 N8150-408 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 3.0 – January 16, 2014 21 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model 4.2.8 Up to six Drives with RAID 0/1 Controller with 0 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (0MB, RAID 0/1) LSI MegaRAID SAS 9240-8i RAID0/1/10, no cache memory, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 3Gb/s Internal SATA Cable mini-SAS to mini-SAS, miniSAS – 2x Single SATA 2.5-inch Drive Cage 4 x 2.5-inch hot plug drive bays 2.5-Inch Hot Plug Drive Cage Kit 2x 2.5-inch hot plug drive bays Including 1x mini-SAS to 2x Single SATA cable 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm N8103-171 Cable Drive Cage Required Optional Drive Cage Required Drive 6 slots available SAS HDD SATA HDD (Standard) N8154-59F N8154-56F N8150-301 N8150-322 N8150-304 N8150-332 N8150-408 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 3.0 – January 16, 2014 22 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model 4.2.9 Up to six Drives with RAID 0/1 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID 0/1) LSI MegaRAID SAS 9267-8i RAID0/1/10, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i Internal SATA Cable mini-SAS to mini-SAS, miniSAS to 2x Single SATA 2.5-inch Drive Cage 4 x 2.5-inch hot plug drive bays 2.5-Inch Hot Plug Drive Cage Kit 2x 2.5-inch hot plug drive bays Including 1x mini-SAS to 2x Single SATA cable 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s N8103-149 RAID BBU Recommended Cable Drive Cage Required Optional Drive Cage Required Drive 6 slots available SAS HDD SATA HDD SAS SSD N8103-155 (Standard) N8154-59F N8154-56F N8150-301 N8150-322 N8150-304 N8150-332 N8150-408 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All hard drives within a RAID array should be of the same capacity and rotation speed. NEC Corporation Revision 3.0 – January 16, 2014 23 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model 4.2.10 Up to six Drives with RAID 5/6 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID 0/1) LSI MegaRAID SAS 9267-8i RAID0/1/5/6/10/50/60, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i Internal SATA Cable mini-SAS to mini-SAS, miniSAS to 2x Single SATA 2.5-inch Drive Cage 4 x 2.5-inch hot plug drive bays 2.5-Inch Hot Plug Drive Cage Kit 2x 2.5-inch hot plug drive bays Including 1x mini-SAS to 2x Single SATA cable 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s N8103-150 RAID BBU Recommended Cable Drive Cage Required Optional Drive Cage Required Drive 6 slots available SAS HDD SATA HDD SAS SSD N8103-155 (Standard) N8154-59F N8154-56F N8150-301 N8150-322 N8150-304 N8150-332 N8150-408 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 3.0 – January 16, 2014 24 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model 4.2.11 Up to six Drives with RAID 5/6 Controller with 1 GB Cache/Battery Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID0/1/5/6) LSI MegaRAID SAS 9267-8i RAID0/1/5/6/10/50/60, 1 GB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i MegaRAID CacheCade for LSI MegaRAID SAS NOTE: - SSD used for cache is required - The SSD capacity which can be used as read cache is up to 512 GB. N8103-151 Internal SATA Cable mini-SAS to mini-SAS, miniSAS to 2x Single SATA 2.5-inch Drive Cage 4 x 2.5-inch hot plug drive bays 2.5-Inch Hot Plug Drive Cage Kit 2x 2.5-inch hot plug drive bays Including 1x mini-SAS to 2x Single SATA cable 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s (Standard) RAID BBU Recommended SSD Caching Recommended Cable Drive Cage Required Optional Drive Cage Required Drive 6 slots available SAS HDD SATA HDD SAS SSD N8103-155 N8103-156 N8154-59F N8154-56F N8150-301 N8150-322 N8150-304 N8150-332 N8150-408 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 3.0 – January 16, 2014 25 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model 4.2.12 Up to six Drives with RAID 5/6 Controller with 1 GB Cache/CacheVault Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) LSI MegaRAID SAS 9270CV-8i (with CV) RAID0/1/5/6/10/50/60, 1GB Cache, Int. 8ports, PCIe 3.0(x8), 6Gb/s, flash cache protection modules included MegaRAID CacheCade for LSI MegaRAID SAS NOTE: - SSD used for cache is required - The SSD capacity which can be used as read cache is up to 512 GB. N8103-167 Internal SATA Cable mini-SAS to mini-SAS, miniSAS to 2x Single SATA 2.5-inch Drive Cage 4 x 2.5-inch hot plug drive bays 2.5-Inch Hot Plug Drive Cage Kit 2x 2.5-inch hot plug drive bays Including 1x mini-SAS to 2x Single SATA cable 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s (Standard) SSD Caching Recommended Cable Drive Cage Required Optional Drive Cage Required Drive 6 slots available SAS HDD SATA HDD SAS SSD N8103-156 N8154-59F N8154-56F N8150-301 N8150-322 N8150-304 N8150-332 N8150-408 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 3.0 – January 16, 2014 26 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model 4.3 3.5-inch Drive Configuration 4.3.1 Up to two Drives with Embedded SATA Controller Category Product Name / Description Part Number Storage Controller Embedded SATA Controller (Standard) 4x 6Gb/s SATA Cable Required Drive Cage Required Drive 2 slots available 4.3.2 Internal SAS/SATA Cable miniSAS to 2x Single SATA 3.5-inch Drive Cage 2 x 3.5-inch non hot plug (fixed) drive bays 500GB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 2TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm K410-278(00) N8154-65F N8150-359 N8150-360 N8150-361 Up to two Drives with Embedded SATA RAID Controller Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 4x 6Gb/s SATA, RAID0/1/10 capable Internal SATA Cable mini-SAS to 2x Single SATA 3.5-inch Drive Cage 2 x 3.5-inch non hot plug (fixed) drive bays 500GB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 2TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 3TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 3TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 4TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm (Standard) Cable Required Drive Cage Required Drive 2 slots available K410-278(00) N8154-65F N8150-359 N8150-360 N8150-361 N8150-362 N8150-396 NOTE: Embedded SATA RAID controller is supported only on Windows operating systems. An optional RAID controller is required to configure RAID array for other operating systems. All hard drives within a RAID array should be of the same capacity. NEC Corporation Revision 3.0 – January 16, 2014 27 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model 4.3.3 Up to two Drives with RAID 0/1 Controller with 0 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (0MB, RAID 0/1) LSI MegaRAID SAS 9240-8i RAID0/1/10, 0MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s Internal SATA Cable mini-SAS to 2x Single SATA 3.5-inch Drive Cage 2 x 3.5-inch non hot plug (fixed) drive bays 500GB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 2TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm N8103-171 Cable Required Drive Cage Required Drive 2 slots available K410-277(00) N8154-65F N8150-359 N8150-360 N8150-361 NOTE: All hard drives within a RAID array should be of the same capacity. 4.3.4 Up to two Drives with RAID 0/1 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID 0/1) LSI MegaRAID SAS 9267-8i RAID0/1/10, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i Internal SATA Cable mini-SAS to 2x Single SATA 3.5-inch Drive Cage 2 x 3.5-inch non hot plug (fixed) drive bays 500GB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 2TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 3TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 3TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 4TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm N8103-149 RAID BBU Recommended Cable Required Drive Cage Required Drive 2 slots available N8103-155 K410-277(00) N8154-65F N8150-359 N8150-360 N8150-361 N8150-362 N8150-396 NOTE: All hard drives within a RAID array should be of the same capacity. NEC Corporation Revision 3.0 – January 16, 2014 28 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model 4.3.5 3.5-inch and 2.5-inch Drives with RAID 0/1 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID 0/1) LSI MegaRAID SAS 9267-8i RAID0/1/10, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i Internal SATA Cable mini-SAS to 2x Single SATA, for 3.5-inch drive cage Internal SAS/SATA Cable mini-SAS to 2x Single SATA, for 2.5-inch drive cage 3.5-inch Drive Cage 2 x 3.5-inch non hot plug (fixed) drive bays 2.5-inch Drive Cage 2 x 2.5-inch non hot plug (fixed) drive bays 500GB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 2TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 3TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 3TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 4TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s N8103-149 RAID BBU Recommended Cable Required Cable Required 3.5-inch Drive Cage Required 2.5-inch Drive Cage Required 3.5-inch Drive 2 slots available 2.5-inch Drive 2 slots available SAS HDD SATA HDD SAS SSD N8103-155 K410-277(00) K410-287(00) N8154-65F N8154-56F N8150-359 N8150-360 N8150-361 N8150-362 N8150-396 N8150-301 N8150-322 N8150-304 N8150-332 N8150-408 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: Hot plug insertion/removal is not supported on the drive configuration. All hard drives within a RAID array should be of the same form factor, capacity and rotation speed. NEC Corporation Revision 3.0 – January 16, 2014 29 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model 5 Internal Optical Drive Category Product Name / Description Part Number Internal 1 slot available Required Internal Slim DVD-ROM drive Slim DVD-ROM drive Internal DVD Super Multi Drive Slim DVD Super Multi drive, not including writing software Optical Drive Bay Cover Blank panel External DVD-ROM drive DVD-ROM drive, Bus powered, 1.2 A required N8151-119 External N8151-107F N8151-121 N8160-91 NOTE: Up to 1 optical drive can be connected. N8151-121 Optical Drive Bay Cover must be installed when not installing any internal optical drives. 6 Internal RDX Drive Category Product Name / Description Part Number Controller Internal USB Controller 1 x USB port Internal USB cable 1x Internal USB to 1x USB device (Standard) Internal RDX (USB) N8151-105 Cable Required Drive 1 bays available K410-276(00) NOTE: The USB driver must be updated with the driver provided with the EXPRESSBUILDER DVD when installing Windows Server 2008 R2 operating systems. 7 PCI Card 7.1 Network Interface Controller Category Product Name / Description Part Number GbE 1000BASE-T Adapter Broadcom ® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x1 Dual Port 1000BASE-T Adapter Broadcom ® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x1 Quad Port 1000BASE-T Adapter Broadcom ® BCM5719 Gigabit Ethernet Controller PCIe 2.0 x4 NOTE: - Network cables with RJ-45 plug covers cannot be used. N8104-138 NEC Corporation Revision 3.0 – January 16, 2014 N8104-132 N8104-133 30 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model NIC Teaming feature – NIC Teaming and bonding features See the table below for supported network interfaces and OS combinations. Windows Server 2008 support BASP (Broadcom Advanced Server Program) or Intel PROSet teaming while Windows Server 2012 or later and Linux support teaming with bonding function supported by OS. Network Interface Team OS GbE NIC Embedded 1GbE NIC and N8104-138/-132/-133 Up to four teams per one system Up to four ports per one team Windows Server 2008 Windows Server 2008 R2 Window Server 2012 Windows Server 2012 R2 Red Hat Linux Using iSCSI See the table below for supported network interfaces and OS combinations. Category Network Interface Operating Systems GbE Embedded 1GbE NIC Windows Server 2008 R2, Windows Serer 2012, RHEL*, VMware N8104-138 Windows Server 2008 R2, Windows Serer 2012, RHEL*, VMware N8104-132 Windows Server 2008 R2, Windows Serer 2012, RHEL*, VMware N8104-133 Windows Server 2008 R2, Windows Serer 2012, RHEL*, VMware * RHEL: Red Hat Enterprise Linux NOTE: NIC Teaming feature is not supported on iSCSI interfaces. 7.2 SAS Controller Product Name / Description Part Number SAS Controller LSI SAS9212-4i4e Host Bus Adapter 6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8 N8103-142 7.3 Serial Port Adapter Product Name / Description Part Number Serial Port Adapter Serial port fixed to PCI bracket N8117-01A NOTE: Up to one Serial Port Adapter can be installed. NEC Corporation Revision 3.0 – January 16, 2014 31 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model 8 Other Add-in Components 8.1 Trusted Platform Module Kit Product Name / Description Part Number Trusted Platform Module Kit TPM 1.2 module N8115-15 NOTE: The kit is not available in China. The kit is not removable after attachment. "TPM Support" in BIOS setup menu must be activated prior to use of this kit. To use Windows BitLocker drive encryption, be sure to keep the "recovery password" of BitLocker function. The recovery password is required to restore data for hardware replacement during a system error. 8.2 Internal Flash Memory Available socket: 1 Product Name / Description Part Number Internal Flash Memory Internal flash memory to enable software and tools in the EXPRESSBUILDR DVD without DVD media NOTE: - Before use, software and tools must be copied from the EXPRESSBUILDER DVD to the flash memory. - The following operations can be performed with the flash memory: - Installation of Windows server with express setup - Installation of Starter Pack—the package of NEC qualified drivers and system setting tools - Installation of NEC ESMPRO Agent and Universal RAID Utility - Performance of the Test and Diagnosis Tool N8115-14 8.3 Flash FDD Choose the Flash FDD if you need to prepare an alternative device for a floppy drive. Product Name / Description Part Number Flash FDD USB flash emulating USB floppy disk, Native capacity 1.44 MB N8160-86 NOTE: Up to one derive can be connected 8.4 Input Devices Product Name / Description Part Number Keyboard and Mouse Pack (US) 1 x 104-keys White USB keyboard, 1 x USB White Optical Wheel Mouse (Standard) NEC Corporation Revision 3.0 – January 16, 2014 32 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model 9 Add-on Components 9.1 Server Management License The server integrates the EXPRESSSCOPE Engine 3 as standard. Refer to Server Management for the standard management features. For more extensive remote KVM and remote media features, choose the following kit. Product Name / Description Part Number Remote KVM and Media License Kit License for one server. Remote KVM and remote media are enabled regardless of OS status. Remote KVM: Displays a graphics console on the web browser of the remote terminal (PC/server). Controls keyboard and mouse via the remote terminals' web browser Remote media: Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals (PC/server) as if accessing the local drives. N8115-04 NOTE: Remote KVM and remote media features are not available for virtual machines. 9.2 Rack Conversion Kit Product Name / Description Part Number Rack Conversion Kit Convert to 3U form factor N8143-94 9.3 Dust Proof Kit The server supports the dust resistant feature. Choose the following kit to install the system in dusty places. Category Product Name / Description Part Number Front Bezel Dust Proof Bezel with Sensor Including 1 set of filter replacement sensors, 1 set of dust proof filters Dust Proof Filter (5 pcs.) For N8146-40 Dust Proof filter Removal capacity of particles : Up to 1 μm-sized N8146-40 Filter 9.4 N8147-23 Tamper Proof Power Button Covers Product Name / Description Part Number Tamper Proof Cover For Standard Bezel Tamper proof cover to prevent erroneous operation of a power button NOTE: - Cannot be used for the Dust Proof Bezel (N8146-39) N8146-42 NEC Corporation Revision 3.0 – January 16, 2014 33 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model 9.5 Medium and Cartridge Category RDX HDD SSD NEC Corporation Product Name Drive supported Part Number RDX Cartridge (320GB) N8151-105 N8153-01 RDX Cartridge (500GB) N8151-105 N8153-02 RDX Cartridge (1TB) N8151-105 N8153-03 RDX Cartridge (1.5TB) N8151-105 N8153-04 RDX Cartridge (SSD/128GB) N8151-105 N8153-06 RDX Cartridge (SSD/256GB) N8151-105 N8153-07 Revision 3.0 – January 16, 2014 34 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model References Server Management The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system management features listed in the table below. Standard Hardware monitoring 1 Temperature/hard drive /fan/voltage/power consumption/ System LAN/degeneration/ 1 (memory/hard drive ) Hardware configuration information collection Hardware event log collection 3 BIOS/POST stall, Booting, OS stall, shutdown Alerting HW error, Boot error and OS panic (by SNMP, E-Mail) Remote KVM (via LAN) POST/BIOS setup, ROM utility 2 2 4 5 CUI-based screen (OS console) 2 5 GUI-based screen (OS console) - Panic screen, Boot screen 4 5 - Remote reset/power on-off/ dump Remote Power Capping BIOS/BMC FW update Remote BIOS setup(partial configuration only) 3 Remote media (CD/DVD/FD/USB) - CLP (Command Line Protocol) (DMTF compliant) Remote control via Web browser (multi user login at the same time) Scheduling (without UPS, require NEC ESMPRO Manager) Maintenance EXPRESSSCOPE® Profile key (Backup/restore BIOS/BMC setup information) Others Set automatic IP address via DNS/DHCP LDAP/Active Directory verification/user control Clock synchronization of main unit and the RTC Access log collection IPMI support 2.0 2.0 3 3 OS shutdown Industry Standard 3 Remote Screen Video Capture 2 3 Boot monitoring Remote control (via LAN) 1 With Remote KVM and Media License kit 3 The feature is not supported on non-hot plug 3.5-inch drive. The standard serial port is not available for the feature. The feature is not supported on VMware systems. Monitoring boot screens is not supported on VMware systems. In VMware systems, only the direct console user interface is supported. NEC Corporation Revision 3.0 – January 16, 2014 35 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model OS Support Matrix for PCI Cards and Embedded Controllers VMware ESXi 5.1 VMware ESXi 5.5 RHEL 5 x64 RHEL 5 RHEL 6 x64 RHEL 6 WS 2008 x64 WS 2008 WS 2008 R2 WS 2012 WS 2012 R2 Part Number Product Name - Embedded SATA non-RAID Controller - - Embedded SATA RAID Controller - - - Embedded 1GbE NIC - N8103-142 SAS Controller - - - N8103-171 RAID Controller (0MB,RAID 0/1) - - - N8103-149 RAID Controller (512MB, RAID 0/1) - N8103-150 RAID Controller (512MB, RAID 0/1/5/6) - N8103-151 RAID Controller (1GB, RAID 0/1/5/6) - N8103-167 RAID Controller (1GB, RAID 0/1/5/6) - N8104-138 1000BASE-T Adapter (1ch) - N8104-133 Quad Port 1000BASE-T Adapter - N8104-132 1000BASE-T Adapter (2ch) - - - - - - Supported PCI cards and Installable Slots Slots Part Number Product Name N8103-142 SAS Controller N8103-171 #2 #3 #4 - RAID Controller (0MB,RAID 0/1) - - - N8103-149 RAID Controller (512MB,RAID 0/1) - - - N8103-150 RAID Controller (512MB,RAID 0/1/5/6) - - - N8103-151 RAID Controller (1GB,RAID 0/1/5/6) - - - N8103-167 RAID Controller (1GB,RAID 0/1/5/6) - - - N8104-138 1000BASE-T Adapter (1ch) N8104-132 1000BASE-T Adapter (2ch) N8104-133 Quad Port 1000BASE-T Adapter N8117-01A Serial Port Adapter NEC Corporation Revision 3.0 – January 16, 2014 #1 36 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries Intel , Xeon and Pentium are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less. The USB interface is not guaranteed to work properly for all USB devices. NEC Corporation Revision 3.0 – January 16, 2014 37 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model Revision History Revision Date Description 3.0 January 16, 2014 New products added: RDX Cartridge (SSD/128G) / N8153-06 RDX Cartridge (SSD/256GB) / N8153-07 Others: Add Windows Server 2012 R2 to the list of operating system supported Update OS support matrix 2.0 October 25, 2013 New products added: Core i3-4330 Processor Kit / N8101-624F Xeon E3-1230 v3 Processor Kit / N8101-628F Xeon E3-1270 v3 Processor Kit / N8101-639F Others: Add N8104-133 Quad Port 1000BASE-T Adapter to the support list Add VMware ESXi 5.5 to the list of operating system supported Update OS support matrix 1.1 August 26, 2013 Others: Corrected the description of N8146-42 Tamper Proof Cover 1.0 July 17, 2013 Initial release NEC Corporation Revision 3.0 – January 16, 2014 38