30 Amp Power PCB Relay PTRH FEATURES CONTACT DATA E86876 Load Type General Purpose Resistive (100.000 Cycles) Motor (30,000 Cycles) LRA/FLA Voltage Most Popular Power PCB Relay Footprint - T90 30 Amp 250 VAC General Purpose UL Rating 2 HP 250 VAC Rating UL Class F Insulation Standard Gold Flashed Contacts Available Meets UL 508 and UL 873 Spacing with Pin 6 Omitted Epoxy Sealed, Immersion Cleanable RoHS Compliant 1 Form A 1 Form B (SPST-NO) (SPDT-NC) 1 Form C NO NC 120 VAC 30 A 20 A 30 A 20 A 250 VAC 30 A 20 A 30 A 20 A 30 VDC 30 A 20 A 30 A 20 A 20 A 20 A 30 A 30 A 2 HP 1 HP 80 A/30 96 A/30 20 A 20 A 120 VAC 30 A 250 VAC 30 A 240 VAC 2 HP 120 VAC 1 HP 240 VAC 80 A/30 A 120 VAC 96 A/30 A —— —— —— —— Material Initial Contact Resistance Maximum Switching Voltage Maximum Switching Current Maximum Switching Power Mechanical Service Life Electrical —— —— —— —— AgSnO2, AgSnO2 50 MΩ Max. @ 1 A, 6 VDC 110 VDC, 300 VAC 30 A 1,500 W, 12,000 VA 1 X 107 Operations 5 X 104 Operations With Pin 6 Omi ed (‐1) Meets UL 508 and UL 873 Spacing ‐ 3.18 mm Through Air, 6.36 mm Over Surface. With Pin 6 Meets UL508 CHARACTERISTIC Continue CHARACTERISTIC Operate Time Release Time Insulation Resistance Dielectric Strength Shock Resistance Power Consumption Less than 15 ms Less than 10 ms 1,000 MΩ min, at 500 VDC, 50% RH 50 Hz 2,500 V 1 Min Between Coil and Contacts 4,000 V without Pin 6 50 Hz 1,500 V 1 min. Between Contacts 200 m/s, 11 ms 0.9 W, 0.6 W Vibration Resistance Terminal Strength Solderability Operating Temperature Range 10 - 55 Hz Double Amplitude Storage Temperature Range - 40°C to 155°C Relative Humidity 85% (at 40°C) Weight Material Compliant To 13.5 gr Approximately 10N 235 ºC for 3 secs - 40°C to 125°C EU RoHS V2, EU REACH V3 ORDERING INFORMATION Example: PTRH -1C -12 S Model: PTRH Contact Form: 1A, 1B, 1C Coil Voltage: 3, 5, 6, 9, 12, 15, 24, 28, 48, 110 Enclosure: Nil: Open Frame; S: Sealed; E: Covered C: Dust Cover Coil Sensitivity: Nil: 0.9 W; 0.6: 0.6 W; 1.1: 1.1 W Contact Material: Nil: AgCdO; T: AgSnO2 Spacing: Nil: UL508; -1: UL 508 and UL 873 (Pin #6 Omitted) RoHS Compliant: -X Box Quantity: 600; Inner Box 300 -1 3220 Commander Drive, Suite 102 Carrollton, TX 75006 Sales: (972) 713-6272 (888) 997-3933 Fax: (972)735-0964 Dimensions are listed for reference purposes only. PTRH Rev G 5/21/15 -X www.PickerComponents.com e-mail: [email protected] Specifications and Availability subject to change without notice. 1 of 2 PTRH PTRH COIL DATA Coil Power (W) Resistance (Ohms ± 10%) Coil Voltage Rated 3 5 6 9 12 15 18 24 28 48 110 Max 3.9 6.5 7.8 11.7 15.6 19.5 23.4 31.2 36.4 62.4 143 0.6 W 0.9 W 1.1 W 15 42 60 135 240 375 540 960 1307 3840 20167 10 28 40 90 150 260 380 640 871 2560 13445 ————33 ——131 ————524 713 2095 ——- Coil Power (W) Must Operate Voltage Max (VDC) 0.6 W & 0.9 W 1.1 W 2.25 ——3.75 ——4.50 4.8 6.75 ——9.00 9.6 10.25 ——13.50 ——18.00 19.2 21.0 22.4 36.00 38.4 82.50 ——- Must Release Voltage Min (VDC) 0.3 0.5 0.6 0.9 1.2 1.5 1.8 2.4 2.8 4.8 11.0 NOTES: The use of any coil voltage less that the rated voltage will compromise the operation of the relays. Must Operate Voltage is listed for test purposes only and is not to be used as design criteria. Pickup and release voltages are for test purposes only and are not to be used as design criteria. Dimensions are in mm, Inches are listed for reference only. DIMENSIONS (mm/inches) Knock off, on top corner, nib for ventilation after soldering and water wash. 5 mm SPDT 12 Amp (‐1) 3.5 mm SPDT 12 Amp Available with Pin 6 UL508 or Without Pin 6 UL873 (‐1) 3220 Commander Drive, Suite 102 Carrollton, TX 75006 Sales: (972) 713-6272 (888) 997-3933 Fax: (972)735-0964 Dimensions are listed for reference purposes only. PTRH Rev G 5/21/15 www.PickerComponents.com e-mail: [email protected] Specifications and Availability subject to change without notice. 2 of 2