50 Amp Power PCB Relay PTRE-T

50 Amp Power PCB Relay
PTRE-T
FEATURES







Most Popular Power PCB Relay Footprint - T90
50 Amp 240 VAC General Purpose UL Rating
2 HP 250 VAC Rating
UL Class F Insulation Standard
Meets UL 508 and UL 873 Spacing
Epoxy Sealed, Immersion Cleanable
RoHS Compliant
E160644 at 40°C
FACTORY RATINGS
1 Form A 1 Form B
(SPST-NO) (SPST-NC)
Load Type
Voltage
Resistive
6,000 Cycles
240 VAC
30 VDC
50 A
Lamp
3,000 Cycles
240 VAC
Electric Ballast
6,000 Cycles
280 VAC
Motor Load
3,000 Cycles
250 VAC
1 Form C
NO
NC
40 A
50 A
40 A
TV-5
—
TV-5
—
5A
—
5A
—
2 HP
1,5 HP
Load Type
1 Form C (SPDT)
Voltage
NO
CONTACT DATA
Material
Initial Contact Resistance
Maximum Switching Voltage
Maximum Switching Current
Maximum Switching Power
2 HP 1.5 HP
15 ms Max.
15 ms Max
1,000 MΩ min, at 500 VDC
Service Life
50 Hz 2,500 V 1 Min Between Coil and Contacts
AgSnO2
30 mΩ Max. @ 1 A, 6 VDC
110 VDC, 300 VAC
50 A
1,500 W, 12,000 VA
Mechanical
Electrical
1 X 107 Operations
5 X 104 Operations
50 Hz 1,500 V 1 min. Between Contacts
235 ºC for 3 secs
Solderability
Operating Temperature Range - 55°C to 100°C
Shock Resistance
200 m/s2, 11 ms
Storage Temperature Range
- 40°C to 155°C
Vibration Resistance
10 - 55 Hz Double Amplitude
Relative Humidity
85% (at 40°C)
Terminal Strength
10N
Weight
33 gr
Power Consumption
1.5 W
Material Compliant To:
EU RoHS V2, EU Reach V3
Dielectric Strength
ORDERING INFORMATION
Example: PTRE
-1C
-12
S
T
Model: PTRE-T
Contact Form: 1A, 1B, or 1C
Coil Voltage: 3, 5, 6, 9, 12, 15, 18, 24, 48, 110
Configuration: Nil: Open Frame; C: Dust Cover;
E: Epoxy Sealed, Not Water Washable
Contact Material: Nil: AgCdO; T: AgSnOInO
Insulation Material: F: UL Class F
Mounting Type: T2: Form 1A or 1B PCB&QC, T3: Form 1C PCB&QC,
OT4: 1A or 1B Panel all QC with Mounting Fins, OT5: 1C Panel all QC with Mounting Fins
RoHS Compliant: -X
Pinout: A: Alternate Quick Connect Pinout
3220 Commander Drive, Suite 102 Carrollton, TX 75006
Sales: (972) 713-6272
(888) 997-3933
Fax: (972)735-0964
Dimensions are listed for reference purposes only.
PTRE Rev C 7/30/15
NC
General Purpose
10,000
240 VAC/30 VDC
50 A
35 A
(Resistive)
50.000
240 VAC/30 VDC
40 A
30 A
Meets UL 508 and UL 873 Spacing - 3.18 mm Through Air, 6.36 mm
Over Surface.
CHARACTERISTIC
Operate Time
Release Time
Insulation Resistance
Cycles
-T5
-X
www.PickerComponents.com
e-mail: [email protected]
Specifications and Availability subject to change without notice.
1 of 2
PTRE-T
PTRE-T
COIL DATA
Coil Voltage
Rated
3
5
6
9
12
15
18
24
48
110
Max
3.9
6.5
7.8
11.7
15.6
19.5
23.4
31.2
62.4
143
Resistance
(Ohms ± 10%)
Must Operate
Voltage Max
(VDC)
Must Release
Voltage Min.
(VDC)
Coil
Power
(W)
6.0
16.7
24.0
54.0
96.0
150
216
384
1,536
8,067
2.25
3.75
4.50
6.75
9.00
10.25
13.50
18.00
36.00
82.50
0.3
0.5
0.6
0.9
1.2
1.5
1.8
2.4
4.8
11.0
1.5
NOTES:
The use of any coil voltage less that the rated voltage will compromise the operation of the relays. Must Operate Voltage is listed for test purposes only and is
not to be used as design criteria. Pickup and release voltages are for test purposes only and are not to be used as design criteria.
Dimensions are in mm, Inches are listed for reference only.
DIMENSIONS (mm/inches)
Knock off, on top corner, nib for ventilation after soldering and water wash.
T4 & T5
T2 & T3
Mounting (Bottom View)
Wiring Diagram (Bottom View)
3220 Commander Drive, Suite 102 Carrollton, TX 75006
Sales: (972) 713-6272
(888) 997-3933
Fax: (972)735-0964
Dimensions are listed for reference purposes only.
PTRE Rev C 7/30/15
www.PickerComponents.com
e-mail: [email protected]
Specifications and Availability subject to change without notice.
2 of 2