PCS27 (AC Output) Data Sheet.pub

 AC Output Solid State Relay
PCS27 AC Output
FEATURES






2 A or 3 A Output
DC Input: 5 VDC; 12 VAC; 24 VAC
PCB Mount
Built in Snubber
Photoelectric Isolation
RoHS Compliant
E93397
INPUT PARAMETERS (Ta = 25°C)
5
12
24
5
12
24
Control Voltage Range
Must Turn-On Voltage
OUTPUT PARAMETERS (Ta = 25°C)
4 - 6 VDC
9.6 - 14.4 VDC
19.2 - 28.8 VDC
4 VAC
9.6 VAC
19.2 VAC
2,240
2, 380
2,240
3,380
Load Voltage Range
48-280
VAC
48-440
VAC
48-280
VAC
48-440
VAC
Max. Transient Voltage
Load Current Range
Max. Surge Current (10 ms)
600 Vpk 800 Vpk 600 Vpk 800 Vpk
0.1 - 2 A
0.1 - 3 A
60 Apk
80 Apk
25 mA
Max. I2t (10 ms, A2s)
5
250 Ω
Max. On-State Voltage Drop
12
720 Ω
Max. Off-State Leakage Current
24
1.64 kΩ
Min. Off-State dv/dt
200 V/us
1 VDC
Max. Turn-On Time
Zero Cross: 1/2 Cycles + 1 ms;
Random: 1 ms
Max. Turn-Off Time
1/2 Cycles + 1 ms
Frequency Range
47 - 63 Hz
Min. Power Factor
0.5
Max. Input Current
Input Resistance
Amperage, Voltage
Must Turn-Off Voltage
18
32
1.5 VRMS
5 mA
CHARACTERISTICS
Dielectric Strength 4,000 VAC, 50 Hz/60 Hz, 1 min. (Input to Output)
Operating Temperture
- 30°C to 80°C
Insulation Resistance 1,000 MΩ at 500 VDC (Input to Output)
Storage Temperature
- 30°C to 100°C
Relative Humidity
Max. Capacitance
8 pF (Input to Output)
Shock Resistance
Acceleration 980 m/s2, Continuous Surge 6 ms
Vibration Resistance Weight
45% - 85%
Approximately 70 g
10 Hz - 55 Hz 1.5 mmm DA
ORDERING INFORMATION
Example: PCS27 Model: PCS27 AC Output
‐12D ‐240A ‐2 Z Control Voltage: 5D: 4‐6 VDC 12D: 9.6 ‐ 14.4 VDC, 24D: 19.2 ‐ 28.8 VDC Load Voltage: 240A: 240VAC, 380A: 380 VAC Load Current: 2: 2 Amp, 3: 3 Amp Switching Type: Z: Zero Crossing, R: Random Turn‐On Box Quantity: 540; Inner Box 27
3220 Commander Drive, Suite 102 Carrollton, TX 75006
Sales: (972) 713-6272
(888) 997-3933
Fax: (972)735-0964
Dimensions are listed for reference purposes only.
PCS27 AC Output Rev A 8/4/15
www.PickerComponents.com
e-mail: [email protected]
Specifications and Availability subject to change without notice.
1 of 2
PCS27 AC Output
PCS27 AC Output
PRECAUTIONS
1.
2.
3.
4.
5.
Maximum Soldering Temperatures: 260°C for a maximum of 10 seconds or 350°C for a maximum of 5 seconds.
The SSR case serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, the load current must be
reduced. Please refer to the curve of "Max. Load current Vs. Ambient Temperature".
The input circuitry does not incorporate a circuit protecting the SSR from being damaged due to a reversed connection. Make sure that the polarity and the
input and output are correct when connecting.
If the output transient voltage exceeds the nominal value a varistor should be mounted on the SSR output terminals in parallel to prevent a breakdown of
the triac output junction. The result could be a permanent short of the output. The recommended varistor voltage 470V.
When using the relay in phase control applications, at a phase control angle close to 180 degrees the relay's input signal will turn off at the trailing edge of
the AC sine wave. The phase delay must be limited to end 200us before AC zero cross. This assures that the relay has time to switch off. Shorter times
may cause loss of control at the following half cycle.
DIMENSIONS (mm)
CHARACTERISTIC CURVES
3220 Commander Drive, Suite 102 Carrollton, TX 75006
Sales: (972) 713-6272
(888) 997-3933
Fax: (972)735-0964
Dimensions are listed for reference purposes only.
PCS27 AC Output Rev A 8/4/15
www.PickerComponents.com
e-mail: [email protected]
Specifications and Availability subject to change without notice.
2 of 2