PCS27 DC Out - Picker Components

 DC Output Solid State Relay
PCS27 DC Output
FEATURES






2 A or 3 A Output
DC Input: 5 VDC; 12 VAC; 24 VAC
PCB Mount
Built in Snubber
Photoelectric Isolation
RoHS Compliant
E93379
INPUT PARAMETERS (Ta = 25°C)
5
12
24
5
12
24
Control Voltage Range
Must Turn-On Voltage
OUTPUT PARAMETERS (Ta = 25°C)
4 - 6 VDC
9.6 - 14.4 VDC
19.2 - 28.8 VDC
4 VAC
9.6 VAC
19.2 VAC
Must Turn-Off Voltage
Max. Input Current
Input Resistance
Load Voltage Range
Max. Transient Voltage
Load Current Range
Max. Surge Current (10 ms)
Max. On-State Voltage Drop
50D
3 - 60 VDC
60 Vpk
100D
3 - 100 VDC
100 Vpk
0.1 - 2 A
8 Apk
1.5 VDC
1 VDC
Max. Off-State Leakage Current
0.1 mA
5
25 mA
Max. Turn-On Time
0.5 ms
12
25 mA
Max. Turn-Off Time
1 ms
24
25 mA
5
250 Ω
12
720 Ω
24
1.64 kΩ
CHARACTERISTICS
Dielectric Strength 2500 VAC, 50 Hz/60 Hz, 1 min. (Input to Output)
Operating Temperture
- 30°C to 85°C
Insulation Resistance 1000 MΩ at 500 VDC (Input to Output)
Storage Temperature
- 30°C to 100°C
Max. Capacitance
Shock Resistance
8 pF (Input to Output)
Acceleration 980
Vibration Resistance m/s2,
Continuous Surge 6 ms
Relative Humidity
Weight
45% - 85%
Approximately 20 g
10 Hz - 55 Hz 1.5 mmm DA
ORDERING INFORMATION
Example: PCS27 ‐12D ‐50D ‐2 Z Model: PCS27 DC Output
Control Voltage: 5D: 4‐6 VDC 12D: 9.6 ‐ 14.4 VDC, 24D: 19.2 ‐ 28.8 VDC Load Voltage: 50D: 50VDC 100D: 100VDC Load Current: 2: 2 Amp, 3: 3 Amp Switching Type: Z: Zero Crossing, R: Random Turn‐On Box Quantity: 540; Inner Box 27
3220 Commander Drive, Suite 102 Carrollton, TX 75006
Sales: (972) 713-6272
(888) 997-3933
Fax: (972)735-0964
Dimensions are listed for reference purposes only.
PCS27 DC Output Rev B 9/16/2015
www.PickerComponents.com
e-mail: [email protected]
Specifications and Availability subject to change without notice.
1 of 2
PCS27 DC Output
PCS27DC Output
PRECAUTIONS
1. Soldering must be completed within 10s at 260°C or less or within 5s at 350°C or less.
2. The SSR case serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, the load current must be
reduced. Please refer to the curve of Max. Load current Vs Ambient Temperature.
3.. Please do not use the relay beyond the description in the data sheet. If it is a must to use it beyond description, please contact Jinxinrong for more technical
support.
DIMENSIONS (mm)
CHARACTERISTIC CURVES
3220 Commander Drive, Suite 102 Carrollton, TX 75006
Sales: (972) 713-6272
(888) 997-3933
Fax: (972)735-0964
Dimensions are listed for reference purposes only.
PCS27 DC Output Rev B 9/16/2015
www.PickerComponents.com
e-mail: [email protected]
Specifications and Availability subject to change without notice.
2 of 2