DC Output Solid State Relay PCS32 (100 mA DC Output) FEATURES • • • • • E93379 INPUT PARAMETERS (Ta = 25°C) Control Voltage Range Must Turn-On Voltage Must Turn-Off Voltage Max. Input Current Small Dimension for High Packing Density PCB Assembly or Socket Mount 2,500 VRMS Opto-Isolation Between Input and Output TTL and CMOS compatible For Interface Application Between PLC and External Loads RoHS Compliant OUTPUT PARAMETERS (Ta = 25°C) 5 4 - 6 VDC 12 24 60 5 12 24 9.6 - 14.4 VDC 19.2 - 28.8 VDC 48 - 72 VDC 4 VAC 9.6 VAC 19.2 VAC 60 48 VDC 5 1 VDC 12 3 VDC 24 10 VDC 60 20 VDC 5 15 mA 12 15 mA 24 10 mA 60 5 mA Load Voltage Range Block Voltage Load Current Max. On-State Voltage Drop Max. Turn-On Time Max. Turn-Off Time 3 - 57.6 VDC 58 VDC 100 mA 1.2 VDC 100us 1,000 us Max. Off-State Leakage Current 200 uA CHARACTERISTICS 2,500 VAC, 1 min. Input to Output Dielectric Strength Insulation Resistance Vibration Resistance 1,000 MΩ at 500 VDC (Input to Output) Recommended Soldering Temperature Operating Temperature - 30°C to 80°C Storage Temperature - 30°C to 100°C Relative Humidity 10 Hz - 55 Hz 1.5 mmm DA 45% - 85% Weight 260°C, 10 s or 350°C, 5 s 4g Shock Resistance Acceleration 980 m/s2, Continuous Surge 6 ms ORDERING INFORMATION Example: PCS32 -12D -48A Model: PCS32 100 mA DC Output Control Voltage: 5D: 5 VDC; 12D: 12 VDC; 24D: 24 VDC; 60D: 60 VDC Load Voltage: 48D: 48 VDC Load Current: T1: 100 mA RC Snubbber: Nil: Without RC Snubber Box Quantity: 2000; Inner Box 100 -T1 3220 Commander Drive, Suite 102 Carrollton, TX 75006 Sales: (972) 713-6272 (888) 997-3933 Fax: (972)735-0964 Dimensions are listed for reference purposes only. PCS32 (100 mA DC Output) Rev A 8/5/15 www.PickerComponents.com e-mail: [email protected] Specifications and Availability subject to change without notice. 1 of 2 PCS32 100 mA DC Output PCS32 100 mA DC Output PRECAUTIONS 1. Soldering must be completed within 10s at 260 °C or less or within 5s at 350 °C or less. 2. The SSR case serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoid‐ able, the load current must be reduced. Please refer to the curve of Max. Load current Vs. Ambient Temperature. 3. Please do not use the relay beyond the descriptions in the datasheet. DIMENSIONS (mm) PCS32‐XX‐48D‐T1 3220 Commander Drive, Suite 102 Carrollton, TX 75006 Sales: (972) 713-6272 (888) 997-3933 Fax: (972)735-0964 Dimensions are listed for reference purposes only. PCS32 (100 mA DC Output) Rev A 8/5/15 www.PickerComponents.com e-mail: [email protected] Specifications and Availability subject to change without notice. 2 of 2