700, 750 WATTS MULTIPLE OUTPUT MAX-700 MAX-750 MSC-750 Option F Featuring: • Over 4 watts/in3 power density • 80% overall efficiency • VMEbus and Multibus II system compatibility • Meets international safety agency requirements • All outputs fully regulated ±1% • High peak current for motor starting • AC automatic line selection option Specify the appropriate MAX-700 or MAX-750 and get new design freedom for your high-end computer products. Use a system air cooled MAX-700, an optional self-cooled MAX-700 or standard selfcooled MAX-750. You can reduce your product size by replacing an 11” x 8” x 5” unit with a 58% smaller MAX-750. Build in power supply redundancy by replacing one ordinary switcher with two MAX-700s in the same space. STANDARD MAX SERIES MODEL PWR MAX-703-0512 MAX-704-1205 MAX-753-0512 MAX-754-1205 MAX-754-1212 MAX-754-1224 MAX-754-1252 700 700 750 750 750 750 750 OUTPUT #1 +5V +5V +5V +5V +5V +5V +5V @ @ @ @ @ @ @ 100A 100A 120A 120A 120A 120A 120A OUTPUT #2 +12V +12V +12V +12V +12V +12V +12V @ @ @ @ @ @ @ 12/20A pk 12/20A pk 12/20A pk 12/20A pk 12/20A pk 12/20A pk 12/20A pk OUTPUT #3 -12V @ 10A -12V @ 10A -12V @ 10A -12V @ 10A -12V @ 10A -12V @ 10A -5.2V @ 10A OUTPUT #4 5.2V @ 2A 5.2V @ 2A 12V @ 2A +24V @ 2A 12V @ 2A MASS STORAGE MSC SERIES MODEL MSC-753-0512 PWR 750 OUTPUT #1 +5V @ 120A OUTPUT #2 +12V @ 20/27A pk OUTPUT #3 -12V @ 6A Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com 700, 750 WATTS 13.5”x 5” X 2.6” MAX-700, 750 MSC-750 Dimensions: MAX-700 MAX-700, MSC-750 with Option F, MAX-750, 6.1 lbs - 2.8 kgs 6.4 lbs - 2.9 kgs Inches Millimeters SPECIFICATIONS: ALL MODELS INPUT AC Input: 90-132 Vac/180-264 Vac, 47 to 63 Hz. User selectable. See option “A” for automatic line selection. Internally fused for 15 A. Inrush: Cold start AC current is less than 90 A at 115 Vac and 30 A at 230 Vac. Limited by thermistor. Holdup Time: 16 ms minimum after removal of power, at nominal line, full load. Efficiency: 80% typical. Brownout Protection: Holds regulation to 85 Vac or 170 Vac. OUTPUT Adjustability: User adjustable ±5% minimum. Line & Load Reg: ±1% over AC input range and 0 to 100% load change. Output #1 requires minimum load of 10%. Ripple & Noise: Less than 1% p-p or 100 mV, whichever is greater. Remote Sense (Output #1): Compensates for 250 mV total line drop. Open sense lead protection. Temperature Coefficient: 0.02% per degree C. Stability: 0.1% over 8 hours after 30 minutes warm-up. Transient Response (Output #1): Output voltage returns to within 1% in less than 500 µs for a 50% load change. Peak transient does not exceed 5%. Overload Protection: All outputs are protected against overload and short circuit. Automatic recovery upon removal of fault. Overvoltage Protection (Output #1): Protects load against power supply induced overvoltage. Trip point is factory set so that output voltage cannot exceed 136% of nominal. Remote Inhibit: Contact closure to the negative sense line drops output power to nominal zero. Reverse Voltage: Protected against reverse voltage up to supply current rating. ENVIRONMENTAL Thermal Protection: Shuts down power supply if overheated. Automatic recovery. Temperature Range: 0° to 50°C at full ratings. Derate to half power at 70°C. Safety Agencies: Most models are approved to UL1950; CSA 22.2 #234; IEC 950 and TÜV EN60950, Class 1 SELV., CE 72/23/EEC/93/68EEC (low voltage directive). Conducted RFI: Meets FCC Part 15, Subpart J, Class A; EN55022 Class B; CISPR 22 Class B. Cooling: 30 CFM required to achieve full ratings. Output Isolation: Isolated from ground 50 Vdc. OPTIONS: Option “A”, AC Auto-Range: Automatically selects proper AC line voltage range to enable power operation at either 115 or 230 Vac without user intervention. Option “F”, Fan/Cover Assembly: Cover with integral ball-bearing fan provides proper cooling to achieve full ratings at 50°C ambient temperature. Option “G”, DC Power Good: Provides a TTL “1” open collector when output #1 is above 4.6 V nominal. Not available if option “P” is selected. Option “P”, AC Power Fail: Provides TTL “0” 5 ms before output voltage goes out of regulation band upon loss of AC power. VMEbus compatible, provides 48 mA sink current capability. Not available if option “G” is selected. Consult factory for other available options. AC INPUT FUNCTION Input Select TB1- (L ) TB1- (N) TB1- ( ) 115 VAC Short Line Neutral Safety Ground 230 VAC Open Line 1 Line 2 Safety Ground CONNECTOR 0.250 Male Faston Barrier strip # 6-32 screws 3/8” centers LOCATION Terminal marked +V Terminal marked COM TB2-3 TB2-4 TB2-5 TB2-4 TB2-1 TB2-2 NOTES Main Output Rtn (Common) Bus bars #1/4-20 screws DC OUTPUT FUNCTION Output #1 Output #2 Output #3 Output #4* (If provided) Rtn (Common) Rtn (Common) (+) (-) CONNECTOR Barrier strip #6-32 screws 3/8” centers *Rtn connected to common only if output is polarized in product selection chart STATUS AND CONTROL FUNCTION Remote Sense AC Power Fail, or DC Power Good* Inhibit LOCATION J1-1(+ S) J1-2 (– S) J1-3 (PF) NOTES Output #1 Sense Output #1 Sense Rtn Reference to J1-2 J1-4 (IH) Short to J1-2 CONNECTOR AMP MTA type #640456-4 pin header (locking) *Optional function Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com