Datasheet

PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Description
Features

The PT7C4337A/4337AC serial real-time clock is a
Using external 32.768kHz quartz crystal for
low-power clock/calendar with two programmable time-
PT7C4337A

of-day alarms and a programmable square-wave output.
Using internal 32.768kHz quartz crystal for
Address and data are transferred serially via a 2-wire,
PT7C4337AC

Supports I2C-Bus's high speed mode (400 kHz)

Includes time (Hour/Minute/Second) and calendar
bidirectional bus. The clock/calendar provides seconds,
minutes, hours, day, date, month, and year information.
The date at the end of the month is automatically
(Year/Month/Date/Day) counter functions (BCD
adjusted for months with fewer than 31 days, including
code)
corrections for leap year. The clock operates in either the

Programmable square wave output signal

Two Time-of-Day Alarms

Oscillator Stop Flag

Operating range: 1.8V to 5.5V

Timekeeping range: 1.2V to 1.8V
24-hour or 12-hour format with AM/PM indicator.
The device is fully accessible through the serial interface
while VCC is between 1.8V and 5.5V. I2C operation is
not guaranteed below 1.8V. Timekeeping operation is
maintained with VCC as low as 1.2V.
Table 1 shows the basic functions of PT7C4337A/
4337AC. More details are shown in section: overview of
functions.
Table 1. Basic functions of PT7C4337A/4337AC
Item Function
PT7C4337A
PT7C4337AC
External crystal
Integrated Crystal
Oscillator enable/disable


Oscillator fail detect


12-hour


24-hour


Century bit


Time count chain enable/disable


Alarm interrupt output
2
2
1, 4.096k, 8.192k,
32.768k
1, 4.096k, 8.192k,
32.768k


Source
1
Oscillator
Time
display
2
Time
Crystal(32.768KHz)
3
Interrupt
4
Programmable square wave output (Hz)
5
Communication
2-wire I2C bus
2014-10-0002
PT0480-2
1
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pin Assignment
PT7C4337A
PT7C4337AC
1
X1
VCC
2
X2
3
INTA
SCL
4
GND
SDA
PT7C4337AC
8
1
SCL
SDA 16
NC 1
8
SQW/INTB 7
2
SQW/INTB
GND 15
NC 2
7 SQW/INTB
6
3
VCC
INTA 14
INTA 3
6
SCL
5
4
NC
NC 13
GND 4
5
SDA
5
NC
NC 12
SOIC-8, MSOP-8,
TDFN-8, TSSOP-8
VCC
DFN4x4-8L
6
NC
NC 11
7
NC
NC 10
8
NC
NC
9
SOIC-16
Pin Description
Pin No.
4337AC 4337AC
4337A
SOIC DFN
Pin
Type
Description
Oscillator Circuit Input. Together with X1, 32.768kHz crystal is connected
between them. Or external clock input.
Oscillator Circuit Output. Together with X1, 32.768kHz crystal is connected
between them. When 32.768kHz external input, X2 must be float.
Serial Clock Input. SCL is used to synchronize data movement on the I2C serial
interface.
Serial Data Input/Output. SDA is the input/output pin for the 2-wire serial
interface. The SDA pin is open-drain output and requires an external pull-up
resistor.
Interrupt Output. When enabled, INTA is asserted low when the time matches the
values set in the alarm registers. This pin is an open-drain output and requires an
external pull up resistor.
1
/
/
X1
I
2
/
/
X2
O
6
1
6
SCL
I
5
16
5
SDA
I/O
3
14
3
INTA
O
7
2
7
SQW/
INTB
O
Square-Wave/Interrupt Output. Programmable square-wave or interrupt output
signal. It is an open-drain output and requires an external pull up resistor.
8
3
8
VCC
P
Power. Primary power for PT7C4337A.
4
15
4
GND
P
/
5-13
1, 2
NC
Ground.
No Connect. These pins are not connected internally, but must be grounded for
proper operation.
2014-10-0002
PT0480-2
2
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Maximum Ratings
Storage Temperature ............................................................ -65℃ to +150℃
Ambient Temperature with Power Applied ........................... -40℃ to +85℃
Supply Voltage to Ground Potential (VCC to GND) ............... -0.3V to +6.5V
DC Input (All Other Inputs except Vcc & GND) ...................................... -0.3V to (Vcc +0.3V)
DC Output Voltage (SDA, /INTA, /INTB pins)........................................-0.3V to +6.5V
DC Output Current (FOUT) ............................................... -0.3V to (Vcc +0.3V)
Power Dissipation .............................................320mW(depend on package)
Note:
Stresses greater than those listed under
MAXIMUM RATINGS may cause permanent
damage to the device. This is a stress rating
only and functional operation of the device at
these or any other conditions above those
indicated in the operational sections of this
specification is not implied. Exposure to
absolute maximum rating conditions for
extended periods may affect reliability.
Operating Mode
The amount of current consumed by the PT7C4337A is determined, in part, by the I2C interface and oscillator operation. The
following table shows the relationship between the operating mode and the corresponding I CC parameter.
VCC
Operating Mode
Power
I2C Interface Active
1.8V ≤ VCC ≤ 5.5V
ICC Active (ICCA)
I2C Interface Inactive
1.8V ≤ VCC ≤ 5.5V
ICC Standby (ICCS)
I2C Interface Inactive
1.2V ≤ VCC ≤ 1.8V
Timekeeping (ICCTOSC)
I2C Interface Inactive, Oscillator Disabled
1.2V ≤ VCC ≤ 1.8V
Data Retention (ICCTDDR)
Recommended Operating Conditions
Part No.
Sym.
VCC
VCCT
VOSC
PT7C4337A
PT7C4337AC
Description
VCC supply voltage
Oscillator start up voltage
SCL, SDA
VIH
Input high level
INTA, SQW/INTB
Min
Type
Max
1.8
3.3
5.5
1.2
-
1.8
1.2
-
5.5
0.7VCC
-
VCC+0.3
-
-
5.5
VIL
Input low level
-0.3
-
0.3VCC
TA
Operating temperature
-40
-
85
Unit
V
ºC
DC Electrical Characteristics
Unless otherwise specified, VCC = 1.8~5.5V, TA = -40 °C to +85 °C
Sym.
VCC
VCCT
VOSC
VIL1
VIH1
VIL2
VIH2
IOL
Item
Pin
Condition
Full operation
Timekeeping (Note 5)
Min
1.8
1.2
1.2
-0.3
0.7VCC
3
Typ
Max
Unit
5.5
V
1.8
5.5
V
0.3VCC
V
VCC+0.3
0.53
V
0.53
mA
Supply voltage
VCC
Oscillator voltage
Low-level input voltage
High-level input voltage
Low-level input voltage
High-level input voltage
Low-level output current
VCC
SCL
SCL
X1
X1
SDA, /INTA, /INTB
IIL
Input leakage current
SCL
-1
-
1
A
IOZ
Output current when OFF
SDA, /INTA, /INTB
-1
-
1
A
VOL = 0.4V
2014-10-0002
PT0480-2
3
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DC Electrical Characteristics
Sym.
Item
Pin
Condition
Unless otherwise specified, VCC = 1.3~1.8V, TA = -40 °C to +85 °C
VCC
Note 2, 4, 5
ICCTOSC Timekeeping current
VCC
Note 2,4,5,6
ICCTDDR Data retention current
Unless otherwise specified, VCC = 1.8~3.6V, TA = -40 °C to +85 °C
ICCA
Active supply current
VCC
Note 1, 5
ICCS
Standby current
VCC
Note 2, 3, 5
Unless otherwise specified, VCC = 3.6~5.5V, TA = -40 °C to +85 °C
ICCA
Active supply current
VCC
Note 1, 5
ICCS
Standby current
VCC
Note 2, 3, 5
Note:
1. SCL clocking at max frequency = 400kHz, VIL = 0.0V, VIH = VCC.
2. Specified with 2-wire bus inactive, VIL = 0.0V, VIH = VCC.
3. SQW enabled.
4. Specified with the SQW function disabled by setting INTCN = 1.
5. Using recommended crystal on X1 and X2.
6. Crystal oscillator is disabled.
Min
Typ
Max
Unit
-
450
-
800
160
nA
-
0.6
100
1.0
A
-
1.0
150
1.8
A
Frequency Characteristics
PT4337AC
Sym.
Description
f / f
Frequency tolerance
f/V
Frequency voltage
characteristics
Top
Frequency temperature
characteristics
tSTA
Oscillation start up time
fa
Aging
Condition
TA = +25°C
VDD = 3.3 V
TA = +25°C
VDD = 2 V to 5 V
TA = -10°C to +70°C,
VDD = 3.3 V; +25°C
reference
TA = +25°C
VDD = 3.3 V
TA = +25°C
VDD=3.0 V; first year
2014-10-0002
Rating
Unit
Stability AC: 0 ± 30
 10 -6
±2 Max.
 10 -6 / V
+10 / -120
 10 -6
3 Max.
s
±5 Max.
 10 -6 / year
PT0480-2
4
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Recommended Layout for Crystal (Only for PT7C4337A)
Note: The crystal, traces and crystal input pins
should be isolated from RF generating signals.
Built-in Capacitors Specifications and Recommended External Capacitors
Parameter
Symbol
Typ
Unit
X1 to GND
CG
12
pF
Build-in capacitors
X2 to GND
CD
12
pF
X1 to GND
C1
12
pF
Recommended External capacitors for
crystal CL=12.5pF
X2 to GND
C2
12
pF
X1 to GND
C1
0
pF
Recommended External capacitors for
crystal CL=6pF
X2 to GND
C2
0
pF
Note: The frequency of crystal can be optimized by external capacitor C1 and C2, for frequency=32.768KHz, C1 and C2 should
meet the equation as below:
Cpar + [(C1+CG)*(C2+CD)]/ [(C1+CG)+(C2+CD)] =CL
Cpar is all parasitical capacitor between X1 and X2.
CL is crystal’s load capacitance.
Crystal Specifications
Parameter
Nominal Frequency
Series Resistance
Load Capacitance
Symbol
fO
ESR
CL
Min
-
Typ
32.768
6/12.5
2014-10-0002
Max
70
-
Unit
kHz
k
pF
PT0480-2
5
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
AC Electrical Characteristics
Sym
VHM
VHL
Description
Rising and falling threshold voltage high
Rising and falling threshold voltage low
Value
0.8 VCC
0.2 VCC
Unit
V
V
Signal
VHM
VLM
tr
tf
Over the operating range
Symbol
Item
fSCL
SCL clock frequency
tSU;STA
START condition set-up time
tHD;STA
START condition hold time
tSU;DAT
Data set-up time (RTC read/write)
tHD;DAT1
Data hold time (RTC write)
tHD;DAT2
Data hold time (RTC read)
tSU;STO
STOP condition setup time
Min.
0.6
0.6
200
35
0
0.6
Typ.
-
Max.
400
-
Unit
kHz
s
s
ns
ns
s
s
s
tBUF
tLOW
Bus idle time between a START and STOP condition
When SCL = "L"
1.3
1.3
-
-
tHIGH
When SCL = "H"
0.6
-
-
s
s
-
-
0.3
0.3
50
400
10
100
s
s
ns
pF
pF
ms
tr
Rise time for SCL and SDA
tf
Fall time for SCL and SDA
tSP*
Allowable spike time on bus
CB
Capacitance load for each bus line
CI/O *
I/O Capacitance (SDA, SCL)
TOSF
Oscillator Stop Flag (OSF) Delay
* Note: only reference for design
S
SCL
Sr
tLOW
fSCL
tHIGH
P
tHD;STA
tSP
tSU;STA
tBUF
SDA
tHD;STA
S
Start condition
Sr
Restart condition
tSU;DAT
tHD;DAT
P
tSU;STA
tSU;STO
tHD;STA
Stop condition
2014-10-0002
PT0480-2
6
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Function Block
Alarm 1 Register
Comparator 1
(Sec, Min, Hour, Day/Date)
PT7C4337A
PT7C4337
Alarm 2 Register
Comparator 2
(Min, Hour, Day/Date)
X1
CG
32.768
kHz
X2
OSC
Time Counter
Counter Chain
(Sec,Min,Hour,Day,Date,Month,Year)
CD
Address
Decoder
Control Register
INTA
SQW/INTB
Address
Register
SCL
I /O
Interface
(I2C)
Interrupt Control
Square Wave Output Control
Shift Register
SDA
Oscillator Circuit
PT7C4337A
The PT7C4337A uses an external 32.768 kHz crystal. Table2 specifies several crystal parameters for the external crystal. The
Block Diagram shows a functional schematic of the oscillator circuit. The startup time is usually less than 1 second when using a
crystal with the specified characteristics.
Table2 Crystal Specifications
Parameter
Symbol
Min
Typ
Max
Nominal Frequency
fO
32.768
Series Resistance
ESR
70
Load Capacitance
CL
6/12.5
Note: The crystal, traces, and crystal input pins should be isolated from RF generating signals.
Unit
kHz
k
pF
Clock Accuracy
The accuracy of the clock is dependent upon the accuracy of the crystal and the accuracy of the match between the capacitive
load of the oscillator circuit and the capacitive load for which the crystal was trimmed. Crystal frequency drift caused by
temperature shifts creates additional error. External circuit noise coupled into the oscillator circuit can result in the clock running
fast. Figure 1 shows a typical PC board layout for isolating the crystal and oscillator from noise.
PT7C4337AC
The PT7C4337AC integrates a standard 32,768Hz crystal in the package. Typical accuracy at nominal V CC and +25°C is
approximately 10ppm.
2014-10-0002
PT0480-2
7
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Function Description
Overview of Functions
Clock function
CPU can read or write data including the year (last two digits), month, date, day, hour, minute, and second. Any (two-digit) year
that is a multiple of 4 is treated as a leap year and calculated automatically as such until the year 2100. On a power-on reset (POR),
the time and date are set to 00:00:00 01/01/00 (hh:mm:ss DD/MM/YY) and the Day register is set to 01.
Alarm function
This device has two alarm system (Alarm 1 and Alarm 2) that outputs interrupt signals from INTA or INTB to CPU when the date,
day of the week, hour, minute or second correspond to the setting. Each of them may output interrupt signal separately at a
specified time. The alarm is be selectable between on and off for matching alarm or repeating alarm.
Programmable square wave output
A square wave output enable bit controls square wave output at pin 7. Frequencies are selectable: 1, 4.096k, 8.192k, 32.768k Hz.
Interface with CPU
Data is read and written via the I2C bus interface using two signal lines: SCL (clock) and SDA (data).
Since the output of the I/O pin SDA is open drain, a pull-up resistor should be used on the circuit board if the CPU output I/O is
also open drain.
The SCL's maximum clock frequency is 400 kHz, which supports the I 2C bus's high-speed mode.
Oscillator fail detect
When oscillator fail, PT7C4337A OSF bit will be set.
Oscillator enable/disable
Oscillator and time count chain can be enabled or disabled at the same time by /ETIME bit.
Registers
Allocation of registers
Register definition
Addr.
(hex)*1
Function
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
00
Seconds (00-59)
0
S40
S20
S10
S8
S4
S2
S1
01
Minutes (00-59)
0
M40
M20
M10
M8
M4
M2
M1
02
Hours (00-23 / 01-12)
0
12, /24
H20 or
P, /A
H10
H8
H4
H2
H1
03
Days of the week (01-07)
0
0
0
0
0
W4
W2
W1
04
Dates (01-31)
0
0
D20
D10
D8
D4
D2
D1
05
Months (01-12)
Century
0
0
MO10
MO8
MO4
MO2
MO1
06
Years (00-99)
Y80
Y40
Y20
Y10
Y8
Y4
Y2
Y1
07
Alarm 1: Seconds
A1M1*2
S40
S20
S10
S8
S4
S2
S1
2014-10-0002
PT0480-2
8
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08
Alarm 1: Minutes
A1M2*2
M40
09
Alarm 1: Hours
A1M3*2
12, /24
0A
Alarm 1: Day, Date
A1M4*2
Day,
/Date
H20 or
P, /A
0,
D20
0B
Alarm 2: Minutes
A2M2*3
M40
M20
0C
Alarm 2: Hours
A2M3*3
12, /24
0D
Alarm 2: Day, Date
A2M4*3
Day,
/Date
H20 or
P, /A
0,
D20
0E
Control
/ETIME*4
0
0F
Status
0
OSF*9
M20
M10
M8
M4
M2
M1
H10
H8
H4
H2
H1
0,
D10
0,
D8
W4,
D4
W2,
D2
W1,
D1
M10
M8
M4
M2
M1
H10
H8
H4
H2
H1
0,
D10
0,
D8
W4,
D4
W2,
D2
W1,
D1
0
RS2*5
RS1*5
A2IE*7
A1IE*7
0
0
0
A2F*8
A1F*8
INTCN*6
0
Caution points:
*1. PT7C4337A uses 8 bits for address. For excess 0FH address, PT7C4337A will not respond (no acknowledge signal was given).
*2. Alarm 1 mask bits. Select alarm repeated rate when an alarm occurs.
*3. Alarm 2 mask bits. Select alarm repeated rate when an alarm occurs.
*4. Oscillator and time count chain enable/disable bit.
*5. Square wave output frequency select.
*6. Interrupt output pin select bit.
*7. Alarm 1 and alarm 2 enable bits.
*8. Alarm 1 and alarm 2 flag bits.
*9. Oscillator stops flag.
*10. All bits marked with "0" are read-only bits. Their value when read is always "0".
Control and status register
Addr.
(hex)
Description
D7
D6
D5
D4
D3
D2
D1
D0
0E
Control
(default)
/ETIME
0
0
0
0
0
RS2
1
RS1
1
INTCN
0
A2IE
0
A1IE
0
0F
Status
(default)
OSF
1
0
0
0
0
0
0
0
0
0
0
A2F
A1F
Undefined Undefined
Oscillator related bits

/ETIME
Enable oscillator and time count chain bit.
/ETIME
Data
Description
0
Enable oscillator and time count chain.
1
Disable oscillator and time count chain.
Default
Read / Write

OSF
Oscillator Stops Flag.
A logic 1 in this bit indicates that the oscillator either is stopped or was stopped for some period of time and may be used to judge
the validity of the clock and calendar data. This bit is set to logic 1 anytime that the oscillator stops. The following are examples
of conditions that can cause the OSF bit to be set:
1) The first time power is applied.
2) The voltage present on VCC is insufficient to support oscillation.
3) The /ETIME bit is turned off.
4) External influences on the crystal (e.g., noise, leakage, etc.).
This bit remains at logic 1 until written to logic 0.
2014-10-0002
PT0480-2
9
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Square wave frequency selection bits

RS2, RS1
Square wave Rate Select. These bits control the frequency of the square-wave output when the square wave has been enabled.
RS2, RS1
Data
SQW output freq. (Hz)
00
1
01
4.096k
10
8.192k
11
32.768k
Read / Write
Default
Interrupt related bits

INTCN
Interrupt Output pin select bit. This bit controls the relationship between the two alarms and the interrupt output pins.
INTCN
Data
Description
1
A match between the timekeeping registers and the alarm 1 registers activates the INTA pin (if the
alarm 1 is enabled) and a match between the timekeeping registers and the alarm 2 registers activates
the SQW/INTB pin (if the alarm 2 is enabled).
0
A match between the timekeeping registers and either alarm 1 or alarm 2 registers activates
the INTA pin (if the alarms are enabled). In this configuration, a square wave is output on
the SQW/INTB pin.
Read /
Write


Default
A1IE
Alarm 1 Interrupt Enable.
Description
A1IE
Data
Read / Write
0
The A1F bit does not initiate the INTA signal.
1
Permits the alarm 1 flag (A1F) bit in the status register to assert INTA.
Default
A1F
Alarm 1 Flag.
A1F
Data
Description
Read / Write
0
The time do not match the alarm 1 registers.
Read
1
Indicates that the time matched the alarm 1 registers. If the A1IE bit is also logic 1, the INTA pin goes
low. A1F is cleared when written to logic 0. Attempting to write to logic 1 leaves the value unchanged.
Default

A2IE
Alarm 2 Interrupt Enable.
A2IE
Data
Read /
Write
Description
Default
0
The A2F bit does not initiate an interrupt signal.
1
Permits the alarm 2 flag (A2F) bit in the status register to assert INTA (when INTCN = 0) or to assert
SQW/INTB (when INTCN = 1).
2014-10-0002
PT0480-2
10
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||

A2F
Alarm 2 Flag.
A1F
Data
Read /
Write
0
The time do not match the alarm 2 registers.
1
Indicates that the time matched the alarm 1 registers. This flag can be used to generate an interrupt on
either INTA or SQW/INTB depending on the status of the INTCN bit. If the INTCN = 0 and A2F = 1
(and A2IE = 1), the INTA pin goes low. If the INTCN = 1 and A2F = 1 (and A2IE = 1), the
SQW/INTB pin goes low. A2F is cleared when written to logic 0. Attempting to write to logic 1 leaves
the value unchanged.
Read
Description
Default
Time Counter
Time digit display (in BCD code):
 Second digits: Range from 00 to 59 and carried to minute digits when incremented from 59 to 00.
 Minute digits: Range from 00 to 59 and carried to hour digits when incremented from 59 to 00.
 Hour digits: See description on the /12, 24 bit. Carried to day and day-of-the-week digits when incremented from 11 p.m. to
12 a.m. or 23 to 00.
Addr.
Description
D7
D6
D5
D4
D3
D2
D1
D0
(hex)
00
Seconds
(default)
0
0
S40
0
S20
0
S10
0
S8
0
S4
0
S2
0
S1
0
01
Minutes
(default)
0
0
M40
0
M20
0
M10
0
M8
0
M4
0
M2
0
M1
0
Hours
0
12, /24 H20 or P,/A
H10
H8
H4
H2
H1
(default)
0
0
0
0
0
0
0
0
Note: Any registered imaginary time should be replaced with correct time, otherwise it will cause the clock counter malfunction.
02

12, /24 bit
This bit is used to select between 12-hour clock system and 24-hour clock system.
12, /24
Data
Description
0
24-hour system
1
12-hour system
Read / Write
2014-10-0002
PT0480-2
11
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
This bit is used to select between 12-hour clock operation and 24-hour clock operation.
12, /24
Description
Hours register
0
24-hour time display
1
12-hour time display
24-hour clock
00
01
02
03
04
05
06
07
08
09
10
11
12-hour clock
52 ( AM 12 )
41 ( AM 01 )
42 ( AM 02 )
43 ( AM 03 )
44 ( AM 04 )
45 ( AM 05 )
46 ( AM 06 )
47 ( AM 07 )
48 ( AM 08 )
49 ( AM 09 )
50 ( AM 10 )
51 ( AM 11 )
24-hour clock
12
13
14
15
16
17
18
19
20
21
22
23
12-hour clock
72 ( PM 12)
61 ( PM 01 )
62 ( PM 02 )
63 ( PM 03 )
64 ( PM 04 )
65 ( PM 05 )
66 ( PM 06 )
67 ( PM 07 )
68 ( PM 08 )
69 ( PM 09 )
70 ( PM 10 )
71 ( PM 11 )
* Be sure to select between 12-hour and 24-hour clock operation before writing the time data.
Days of the week Counter
The day counter is a divide-by-7 counter that counts from 01 to 07 and up 07 before starting again from 01. Values that
correspond to the day of week are user defined but must be sequential (i.e., if 1 equals Sunday, then 2 equals Monday, and so on).
Illogical time and date entries result in undefined operation.
Addr.
Description
D7
D6
D5
D4
D3
D2
D1
D0
(hex)
03
Days of the week
(default)
0
0
0
0
0
0
0
0
0
0
W4
0
W2
0
W1
1
Calendar Counter
The data format is BCD format.
 Day digits: Range from 1 to 31 (for January, March, May, July, August, October and December).
Range from 1 to 30 (for April, June, September and November).
Range from 1 to 29 (for February in leap years).
Range from 1 to 28 (for February in ordinary years).
Carried to month digits when cycled to 1.
 Month digits: Range from 1 to 12 and carried to year digits when cycled to 1.
 Year digits: Range from 00 to 99 and 00, 04, 08, … , 92 and 96 are counted as leap years.
Addr.
(hex)
Description
D7
D6
D5
D4
D3
D2
D1
D0
04
Dates
(default)
0
0
0
0
D20
0
D10
0
D8
0
D4
0
D2
0
D1
1
05
Months
(default)
Century*1
0
0
0
0
0
M10
0
M8
0
M4
0
M2
0
M1
1
06
Years
(default)
Y80
0
Y40
0
Y20
0
Y10
0
Y8
0
Y4
0
Y2
0
Y1
0
*1: The century bit is toggled when the years register overflows from 99 to 00.
2014-10-0002
PT0480-2
12
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Alarm Register

Alarm 1, Alarm 2 Register
Addr.
Description
07
Alarm 1: Seconds
(default)
08
09
0A
0B
0C
0D
Alarm 1: Minutes
(default)
D7
D6
A1M1*1
S40
Undefined Undefined
A1M2*1
M40
Undefined Undefined
D5
D4
S20
Undefined
M20
D3
D2
D1
D0
S10
S8
S4
S2
S1
Undefined Undefined Undefined Undefined Undefined
M10
M8
M4
M2
M1
Undefined
Undefined Undefined Undefined Undefined Undefined
A1M3*1
12, /24
H20 or P,/A
Undefined Undefined Undefined
Day,
0,
Alarm 1: Day, Date A1M4*1
/Date*1
D20
(default)
Undefined Undefined Undefined
H10
H8
H4
H2
H1
Undefined Undefined Undefined Undefined Undefined
0,
0,
W4,
W2,
W1,
D10
D8
D4
D2
D1
Undefined Undefined Undefined Undefined Undefined
Alarm 1: Hours
(default)
Alarm 2: Minutes
(default)
A2M2*2
M40
M10
M8
M4
M2
M1
Undefined
Undefined Undefined Undefined Undefined Undefined
A2M3
12, /24
H20 or P,/A
Undefined Undefined Undefined
Day,
0,
Alarm 2: Day, Date A2M4*2
/Date*2
D20
(default)
Undefined Undefined Undefined
H10
H8
H4
H2
H1
Undefined Undefined Undefined Undefined Undefined
0,
0,
W4,
W2,
W1,
D10
D8
D4
D2
D1
Undefined Undefined Undefined Undefined Undefined
Alarm 2: Hours
(default)
Undefined Undefined
M20
*2
*1 Note: Alarm mask bit, using to select Alarm 1 alarm rate.
*2 Note: Alarm mask bit, using to select Alarm 2 alarm rate.
2014-10-0002
PT0480-2
13
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Alarm Function
Related register
Addr.
Function
(hex)
Bit 7
Bit 6
Bit 5
Register definition
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
00
Seconds
0
S40
S20
S10
S8
S4
S2
S1
01
Minutes
0
M40
M20
M10
M8
M4
M2
M1
02
Hours
0
12, /24
H20 or
A, /P
H10
H8
H4
H2
H1
03
Days of the week
0
0
0
0
0
W4
W2
W1
04
Dates
0
0
D20
D10
D8
D4
D2
D1
07
Alarm 1: Seconds
A1M1
S40
S20
S10
S8
S4
S2
S1
08
Alarm 1: Minutes
A1M2
M40
M20
M10
M8
M4
M2
M1
09
Alarm 1: Hours
A1M3
12, /24
H10
H8
H4
H2
H1
0A
Alarm 1: Day, Date
A1M4
Day,
/Date
H20 or
A, /P
0,
D20
0,
D10
0,
D8
W4,
D4
W2,
D2
W1,
D1
0B
Alarm 2: Minutes
A2M2
M40
M20
M10
M8
M4
M2
M1
0C
Alarm 2: Hours
A2M3
12, /24
H10
H8
H4
H2
H1
0D
Alarm 2: Day, Date
A2M4
Day,
/Date
H20 or
A, /P
0,
D20
0,
D10
0,
D8
W4,
D4
W2,
D2
W1,
D1
0E
Control
/ETIME
0
0
RS2
RS1
INTCN
A2IE
A1IE
0F
Status
OSF
0
0
0
0
0
A2F
A1F
Note: Alarm function does not support different hour system adopted in time and alarm register.
The PT7C4337A contains two time-of-day/date alarms. The alarms can be programmed (by the INTCN bit of the control register)
to operate in two different modes - each alarm can drive its own separate interrupt output or both alarms can drive a common
interrupt output. Bit 7 of each of the time-of-day/date alarm registers are mask bits.
When all of the mask bits for each alarm are logic 0, an alarm only occurs when the values in the timekeeping registers 00h ~ 04h
match the values stored in the time-of-day/date alarm registers. The alarms can also be programmed to repeat every second,
minute, hour, day, or date. Table 2 and Table 3 show the possible settings.
The Day, /Date bits (bit 6 of the alarm day/date registers) control whether the alarm value stored in bits 0 ~ 5 of that register
reflects the day of the week or the date of the month. If the bit is written to logic 0, the alarm is the result of a match with date of
the month. If the bit is written to logic 1, the alarm is the result of a match with day of the week.
When the PT7C4337A register values match alarm register settings, the corresponding alarm flag (A1F or A2F) bit is set to logic
1. If the corresponding alarm interrupt enable (A1IE or A2IE) is also set to logic 1, the alarm condition activates one of the
interrupt output (INTA or SQW/INTB) signals. The match is tested on the once-per-second update of the time and date registers.
2014-10-0002
PT0480-2
14
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Table 1. Alarm 1 Mask Bits
Alarm 1 register mask bits
Day,
/Date
A1M4 A1M3 A1M2 A1M1
Alarm rate

1
1
1
1
Alarm once per second

1
1
1
0

1
1
0
0
Alarm when seconds match
Alarm when minutes and seconds match

1
0
0
0
Alarm when hours, minutes, and seconds match
0
0
0
0
0
Alarm when date, hours, minutes, and seconds match
1
0
0
0
0
Alarm when day, hours, minutes, and seconds match
Others
Ignored.
Table 2. Alarm 2 Mask Bits
Alarm 2 register mask bits
Day,
/Date
A2M4
A2M3
A2M2
1
1
1

Alarm rate
Alarm once per minute (00 seconds of every minute)

1
1
0
Alarm when minutes match

0
1
0
0
Alarm when hours, minutes
0
0
0
Alarm when date, hours, and minutes match
1
0
0
0
Alarm when day, hours, and minutes match
Others
Ignored.
2014-10-0002
PT0480-2
15
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
I2C Bus Interface
Overview of I2C-BUS
The I2C bus supports bi-directional communications via two signal lines: the SDA (data) line and SCL (clock) line. A combination
of these two signals is used to transmit and receive communication start/stop signals, data signals, acknowledge signals, and so on.
Both the SCL and SDA signals are held at high level whenever communications are not being performed. The starting and
stopping of communications is controlled at the rising edge or falling edge of SDA while SCL is at high level. During data
transfers, data changes that occur on the SDA line are performed while the SCL line is at low level, and on the receiving side the
data is captured while the SCL line is at high level. In either case, the data is transferred via the SCL line at a rate of one bit per
clock pulse. The I2C bus device does not include a chip select pin such as is found in ordinary logic devices. Instead of using a
chip select pin, slave addresses are allocated to each device and the receiving device responds to communications only when its
slave address matches the slave address in the received data.
System Configuration
All ports connected to the I2C bus must be either open drain or open collector ports in order to enable AND connections to
multiple devices.
SCL and SDA are both connected to the VDD line via a pull-up resistance. Consequently, SCL and SDA are both held at high
level when the bus is released (when communication is not being performed).
Fig 1. System configuration
Vcc
RP
RP
SDA
SCL
Master
MCU
Slave
RTC
Other Peripheral
Device
Note: When there is only one master, the MCU is ready for driving SCL to "H" and RP of SCL may not required.
2014-10-0002
PT0480-2
16
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Starting and Stopping I2C Bus Communications
Fig 2. Starting and stopping on I2C bus
1) START condition, repeated START condition, and STOP condition
a) START condition
SDA level changes from high to low while SCL is at high level
b) STOP condition
SDA level changes from low to high while SCL is at high level
c) Repeated START condition (RESTART condition)
In some cases, the START condition occurs between a previous START condition and the next STOP condition, in
which case the second START condition is distinguished as a RESTART condition. Since the required status is the same as for the
START condition, the SDA level changes from high to low while SCL is at high level.
2) Data Transfers and Acknowledge Responses during I2C-BUS Communication
a) Data transfers
Data transfers are performed in 8-bit (1 byte) units once the START condition has occurred. There is no limit on the amount
(bytes) of data that are transferred between the START condition and STOP condition.
The address auto increment function operates during both write and read operations.
Updating of data on the transmitter (transmitting side)'s SDA line is performed while the SCL line is at low level.
The receiver (receiving side) captures data while the SCL line is at high level.
*Note with caution that if the SDA data is changed while the SCL line is at high level, it will be treated as a START, RESTART,
or STOP condition.
b) Data acknowledge response (ACK signal)
When transferring data, the receiver generates a confirmation response (ACK signal, low active) each time an 8-bit data segment
is received. If there is no ACK signal from the receiver, it indicates that normal communication has not been established. (This
does not include instances where the master device intentionally does not generate an ACK signal.)
Immediately after the falling edge of the clock pulse corresponding to the 8th bit of data on the SCL line, the transmitter releases
the SDA line and the receiver sets the SDA line to low (= acknowledge) level.
2014-10-0002
PT0480-2
17
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SCL from Master
1
8
2
SDA from transmitter
(sending side)
9
Release SDA
Low active
SDA from receiver
(receiving side)
ACK signal
After transmitting the ACK signal, if the Master remains the receiver for transfer of the next byte, the SDA is released at the
falling edge of the clock corresponding to the 9th bit of data on the SCL line. Data transfer resumes when the Master becomes the
transmitter.
When the Master is the receiver, if the Master does not send an ACK signal in response to the last byte sent from the slave, that
indicates to the transmitter that data transfer has ended. At that point, the transmitter continues to release the SDA and awaits a
STOP condition from the Master.
Slave Address
The I2C bus device does not include a chip select pin such as is found in ordinary logic devices. Instead of using a chip select pin,
slave addresses are allocated to each device.
All communications begin with transmitting the [START condition] + [slave address (+ R/W specification)]. The receiving device
responds to this communication only when the specified slave address it has received matches its own slave address.
Slave addresses have a fixed length of 7 bits. See table for the details.
An R/W bit is added to each 7-bit slave address during 8-bit transfers.
Table
Slave address
R / W bit
Operation
Transfer data
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
Read
D1 h
1 (= Read)
1
1
0
1
0
0
0
Write
D0 h
0 (= Write)
I2C Bus’s Basic Transfer Format
S
Start indication
Sr
Restart indication
P
Stop indication
2014-10-0002
A
RTC Acknowledge
A
Master Acknowledge
PT0480-2
18
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1) Write via I2C bus
Slave address (7 bits)
S
1
Start
1
0
1
0
write
0
0
Addr. setting
A
A
0
A
C
K
Slave address + write specification
A
C
K
Address
Specifies the write start address.
bit
bit
bit
bit
bit
bit
bit
bit
7
6
5
4
3
2
1
0
Write data
A
P
A
C
K
Stop
2) Read via I2C bus
a) Standard read
Slave address (7 bits)
S
1
Start
1
0
1
0
0
write
0
Slave address (7 bits)
1
1
0
1
0
0
A
C
K
Read
0
A
1
A
C
K
Restart
Slave address + read specification
b)
A
0
Slave address + write specification
Sr
Addr. setting
A
A
C
K
Address
Specifies the read start address.
bit
bit
bit
bit
bit
bit
bit
bit
7
6
5
4
3
2
1
0
Data read (1)
Data is read from the specified start
address and address auto increment.
A
A
C
K
bit
bit
bit
bit
bit
bit
bit
bit
7
6
5
4
3
2
1
0
Data read (2)
Address auto increment to set the
address for the next data to be read.
/A
P
N
O
Stop
A
C
K
Simplified read
Slave address (7 bits)
S
1
Start
1
0
1
0
0
Read
0
Slave address + read specification
A
1
A
C
K
bit
bit
bit
bit
bit
bit
bit
bit
7
6
5
4
3
2
1
0
Data read (1)
Data is read from the address pointed
by the internal address register and
address auto increment.
A
A
C
K
bit
bit
bit
bit
bit
bit
bit
bit
7
6
5
4
3
2
1
0
Data read (2)
Address register auto increment to set
the address for the next data to be
read.
/A
P
N
O
Stop
A
C
K
Note:
1. The above steps are an example of transfers of one or two bytes only. There is no limit to the number of bytes transferred
during actual communications.
2. 49H, 4AH are used as test mode address. Customer should not use the addresses.
2014-10-0002
PT0480-2
19
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Mechanical Information
W (SOIC-8L)
2014-10-0002
PT0480-2
20
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
U(MSOP-8L)
2014-10-0002
PT0480-2
21
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
L (TSSOP-8L)
2014-10-0002
PT0480-2
22
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
ZE (TDFN 2x3-8L)
2014-10-0002
PT0480-2
23
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
S (SOIC-16L)
2014-10-0002
PT0480-2
24
11/03/14
PT7C4337A/4337AC
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
ZSA(DFN4x4-8L)
Ordering Information
Part Number
PT7C4337AWE
PT7C4337AUE
PT7C4337AZEE
PT7C4337ALE
PT7C4337ACSE
PT7C4337ACZSAE
Package Code
W
U
ZE
L
S
ZSA
Package
Lead free and Green 8-Pin SOIC
Lead free and Green 8-Pin MSOP
Lead free and Green 8-Pin TDFN 2x3
Lead free and Green 8-Pin TSSOP
Lead free 16-Pin SOIC
Lead free and Green 8-Pin DFN4x4-8L
Notes:

E = Pb-free or Pb-free and Green

Adding X Suffix= Tape/Reel
Pericom Semiconductor Corporation  1-800-435-2336  www.pericom.com
Pericom reserves the right to make changes to its products or specifications at any time, without notice, in order to improve design or performance and to supply
the best possible product. Pericom does not assume any responsibility for use of any circuitry described other than the circuitry embodied in Pericom product. The
company makes no representations that circuitry described herein is free from patent infringement or other rights, of Pericom.
2014-10-0002
PT0480-2
25
11/03/14