DEVICE SPECIFICATIONS NI PXIe-2738 256-Crosspoint Relay Matrix This document lists specifications for the NI PXIe-2738 (NI 2738) matrix relay card. All specifications are subject to change without notice. Visit ni.com/manuals for the most current specifications. Topology ............................................................................2-wire 8 × 32 matrix Contents About These Specifications...................................................................................................... 1 Input Characteristics................................................................................................................. 2 RF Performance Characteristics................................................................................................3 Dynamic Characteristics........................................................................................................... 4 Physical Characteristics............................................................................................................ 4 Environment..............................................................................................................................5 Operating Environment.....................................................................................................5 Storage Environment.........................................................................................................5 Shock and Vibration..................................................................................................................5 Diagrams................................................................................................................................... 6 Accessories................................................................................................................................7 Derating NI 2738 Load at >50 °C.............................................................................................8 Module Load Derating at >50 °C......................................................................................8 Compliance and Certifications..................................................................................................9 Safety................................................................................................................................ 9 Electromagnetic Compatibility......................................................................................... 9 CE Compliance .............................................................................................................. 10 Online Product Certification........................................................................................... 10 Environmental Management........................................................................................... 10 About These Specifications Specifications characterize the warranted performance of the instrument under the stated operating conditions. Typical Specifications are specifications met by the majority of the instrument under the stated operating conditions and are tested at 23 °C ambient temperature. Typical specifications are not warranted. All voltages are specified in DC, ACpk, or a combination unless otherwise specified. Caution The protection provided by the NI 2738 can be impaired if it is used in a manner not described in this document. Input Characteristics Maximum switching voltage .................................................................... Channel-to-channel 100 V Channel-to-ground .................................................................... 100 V, CAT O Note This module is rated for Measurement Category I. It is intended to carry signal voltages no greater than 70 Vrms, 100 Vpk, or 100 VDC. This module can withstand up to 500 V impulse voltage. Do not use this module for connection to signals or for measurements within Categories II, III, or IV. Do not connect to MAINS supply circuits (for example, wall outlets) of 115 VAC or 230 VAC. Measurement Categories CAT I and CAT O (Other) are equivalent and are for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. This category is for measurement of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special hardware, limited-energy parts of hardware, circuits powered by regulated low-voltage sources, and electronics. Caution When hazardous voltages (>42.4 Vpk/60 VDC) are present on any channel, safety low-voltage (≤42.4 Vpk/60 VDC) cannot be connected to any other channel. ............................................................................ Maximum switching power 60 W, 62.5 VA Caution The switching power is limited by the maximum switching current, the maximum voltage, and must not exceed 60 W, 62.5 VA. Maximum current Switching ....................................................................2 A (per channel) Carry .................................................................... 2 A (per channel) Minimum switching load ............................................................................ 20 mV/1 mA Note Switching inductive loads (for example, motors and solenoids) can produce high voltage transients in excess of the module’s rated voltage. Without additional protection, these transients can interfere with module operation and impact relay life. 2 | ni.com | NI PXIe-2738 Specifications For more information about transient suppression, visit ni.com/info and enter the Info Code relayflyback. DC ............................................................................ isolation resistance 1 GΩ (typical at 25º C) (channel-to-COM) DC path resistance Initial .................................................................... <1.3 Ω End-of-life .................................................................... ≥2.3 Ω Path resistance is a combination of relay contact resistance and trace resistance. Measure path resistance by combining resistance of the high and low signal paths from one row to one column. Contact resistance typically remains low for the life of a relay. At the end of relay life, the contact resistance rises rapidly above ≥2.3 Ω. Thermal ............................................................................ EMF <10 µV RF Performance Characteristics Bandwidth (-3 dB, typical at 23º C) .................................................................... 1-wire 50 Ω termination ≤ 10 MHz 2-wire 100 Ω termination .................................................................... ≤ 10 MHz Open channel isolation (typical at 23º C, 50 Ω termination ) 10 kHz .................................................................... ≥ 84 dB 100 kHz .................................................................... ≥ 71 dB 1 MHz .................................................................... ≥ 50 dB Channel-to-channel crosstalk (typical at 23º C, 50 Ω termination ) 10 kHz .................................................................... ≤ -69 dB 100 kHz .................................................................... ≤ -52 dB 1 MHz .................................................................... ≤ -33 dB NI PXIe-2738 Specifications | © National Instruments | 3 Dynamic Characteristics Relay Operate Time .................................................................... Typical 1 ms Maximum .................................................................... 3.3 ms Simultaneous drive limit ............................................................................ 90 relays Expected mechanical relay life ............................................................................ 1 × 108 cycles Expected electrical relay life ≤30 mV, ≤10 mA resistive .................................................................... 2.5 × 106 cycles 30 V, 1 A .................................................................... 5 × 105 cycles 30 V, 2 A .................................................................... 1 × 105 cycles 60 VDC, 1 ADC resistive .................................................................... 1 × 105 cycles Note Relays are field replaceable. Refer to the NI Switches Help at ni.com/ manuals for more information about replacing a failed relay. Note Certain applications may require additional time for proper settling. Refer to the NI Switches Help at ni.com/manuals for more information about including additional settling time. Physical Characteristics ............................................................................ Relay type Electromechanical, non-latching Relay contact material ............................................................................ Palladium-ruthenium, gold covered Front panel connector ............................................................................ 160 DIN 41612, 160 positions, male Power requirement PXI Express 12 V ............................................................ 24 W 3.3 V ............................................................ 3.6 W Dimensions (L × W × H) ............................................................................ 3U, one slot, PXI/cPCI module, PXI Express compatible 21.6 cm × 2.0 cm × 13.0 cm (8.5 in. × 0.8 in. × 5.1 in.) Weight ............................................................................423 g (14.9 oz) 4 | ni.com | NI PXIe-2738 Specifications Environment Maximum ............................................................................ altitude 2,000 m (800 mbar) (at 25 °C ambient temperature) Pollution Degree ............................................................................ 2 Indoor use only. Operating Environment ............................................................................ Ambient temperature range 0 °C to 55 °C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2. Meets MIL-PRF-28800F Class 3 low temperature limit and MIL-PRF-28800F Class 2 high temperature limit.) Relative ............................................................................ humidity range 10% to 90%, noncondensing (Tested in accordance with IEC 60068-2-56.) Related Information Derating NI 2738 Load at >50 °C on page 8 Storage Environment Ambient ............................................................................ temperature range -40 °C to 71 °C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2. Meets MIL-PRF-28800F Class 3 limits.) Relative ............................................................................ humidity range 5% to 95%, noncondensing (Tested in accordance with IEC 60068-2-56.) Shock and Vibration ............................................................................ Operating shock 30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC 60068-2-27. Meets MIL-PRF-28800F Class 2 limits.) Random vibration Operating .................................................................... 5 Hz to 500 Hz, 0.3 grms Nonoperating .................................................................... 5 Hz to 500 Hz, 2.4 grms (Tested in accordance with IEC 60068-2-64. Nonoperating test profile exceeds the requirements of MIL-PRF-28800F, Class 3.) NI PXIe-2738 Specifications | © National Instruments | 5 Diagrams The following figure shows the NI 2738 power-on state. Figure 1. NI 2738 Power-On State (C0+, C0–) (C1+, C1–) (C31+, C31–) (R0+, R0–) (R1+, R1–) (R6+, R6–) (C1–) (C1+) (R7+, R7–) (R6+) (R6–) The following figure shows the NI 2738 connector pinout. 6 | ni.com | NI PXIe-2738 Specifications Figure 2. NI 2738 Connector Pinout CO– CO+ C2– C2+ C4– C4+ C6– C6+ C8– C8+ C10– C10+ C12– C12+ C14– C14+ C16– C16+ C18– C18+ C20– C20+ C22– C22+ C24– C24+ C26– C26+ C28– C28+ C30– C30+ B32 A32 B31 A31 B30 A30 B29 A29 B28 A28 B27 A27 B26 A26 B25 A25 B24 A24 B23 A23 B22 A22 B21 A21 B20 A20 B19 A19 B18 A18 B17 A17 C0– C32 D32 E32 C31 D31 E31 C30 D30 E30 C29 D29 E29 C28 D28 E28 C27 D27 E27 C26 D26 E26 C25 D25 E25 C24 D24 E24 C23 D23 E23 C22 D22 E22 C21 D21 E21 C20 D20 E20 C19 D19 E19 C18 D18 E18 C17 D17 E17 C16 C1+ C1– R0+ C3+ C3– R0– C5+ C5– R1+ C7+ C7– R1– C9+ C9– R2+ C11+ C11– R2– C13+ C13– R3+ C15+ C15– R3– C17+ C17– R0+ C19+ C19– R0– C21+ C21– R1+ C23+ C23– R1– C25+ C25– R2+ C27+ C27– R2– C29+ C29– R3+ C31+ C31– R3– C1+ C1– C30+ C0– C0+ C2– C2+ C4– C4+ C6– C6+ C8– C8+ C10– C10+ C12– C12+ C14– C14+ C16– C16+ C18– C18+ C20– C20+ C22– C22+ C24– C24+ C26– C26+ C28– C28+ C30– C30+ A17 C16 D16 E16 C15 D15 E15 C14 D14 E14 B16 A16 B15 A15 B14 A14 C13 D13 E13 C12 D12 E12 B13 A13 B12 A12 C11 D11 E11 B11 A11 C10 D10 E10 B10 A10 C9 D9 E9 C8 D8 E8 B9 A9 B8 A8 C7 D7 E7 C6 D6 E6 C5 D5 E5 C4 D4 E4 B7 A7 B6 A6 B5 A5 B4 A4 C3 D3 E3 B3 A3 C2 D2 E2 C1 D1 E1 B2 A2 B1 A1 C1+ C1– R4+ C3+ C3– R4– C5+ C5– R5+ C7+ C7– R5– C9+ C9– R6+ C11+ C11– R6– C13+ C13– R7+ C15+ C15– R7– C17+ C17– R4+ C19+ C19– R4– C21+ C21– R5+ C23+ C23– R5– C25+ C25– R6+ C27+ C27– R6– C29+ C29– R7+ C31+ C31– R7– Accessories Table 1. NI Accessories for the NI 2738 Accessory Part Number DIN160 to 50-pin D-SUB switch cable, 1 m 782417-03 DIN160 to DIN160 switch cable, 1 m 782417-02 NI PXIe-2738 Specifications | © National Instruments | 7 Table 1. NI Accessories for the NI 2738 (Continued) Accessory Part Number DIN160 to bare wire switch cable, 1 m 782417-01 Relay replacement kit for IM02PNS Relays 781089-10 Derating NI 2738 Load at >50 °C To verify you are operating the NI 2738 within supported 2-wire derating conditions, complete the following steps: 1. Use the following equation to calculate the load: Load = Channels1 × Current1 2 + Channels2 × Current2 2 + ... + Channels� × Current� 2 where Channels is the number of channels that simultaneously carry a signal, Current, for 1, ... , n. 2. Verify that the load at your ambient operating temperature falls within the shaded region of the following figure. Figure 3. NI 2738 Load Derating, 2-Wire 35 Power Load (Amps 2 x Channels) 30 25 20 15 10 5 0 15 20 25 35 40 45 50 Ambient Temperature (°C) Module Load Derating at >50 °C The following examples calculate supported derating conditions for the NI 2738. 8 | ni.com | NI PXIe-2738 Specifications 55 Example 1 where (3 × 22) + (4 × 1.72) = 23.6�2 × channels 3 channels carry 2 A 4 channels carry 1.7 A You can use this module at ambient temperatures between 0 °C and 55 °C. Example 2 where (8 × 22) = 32�2 × channels 8 channels carry 2 A You can use this module at ambient temperatures between 0 °C and 50 °C. Compliance and Certifications Safety This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 61010-1, CSA 61010-1 Note For UL and other safety certifications, refer to the product label or the Online Product Certification section. Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: • EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity • EN 55011 (CISPR 11): Group 1, Class A emissions • EN 55022 (CISPR 22): Class A emissions • EN 55024 (CISPR 24): Immunity NI PXIe-2738 Specifications | © National Instruments | 9 • • • • AS/NZS CISPR 11: Group 1, Class A emissions AS/NZS CISPR 22: Class A emissions FCC 47 CFR Part 15B: Class A emissions ICES-001: Class A emissions Note In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations. In Europe, Canada, Australia, and New Zealand (per CISPR 11), Class A equipment is intended for use only in heavy-industrial locations. Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes. Note For EMC declarations, certifications, and additional information, refer to the Online Product Certification section. CE Compliance This product meets the essential requirements of applicable European Directives, as follows: • 2006/95/EC; Low-Voltage Directive (safety) • 2014/30/EU; Electromagnetic Compatibility Directive (EMC) Online Product Certification Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for this product, visit ni.com/ certification, search by model number or product line, and click the appropriate link in the Certification column. Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the Minimize Our Environmental Impact web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/environment/weee. 10 | ni.com | NI PXIe-2738 Specifications 电子信息产品污染控制管理办法(中国 RoHS) 中国客户 National Instruments 符合中国电子信息产品中限制使用某些有害物 质指令(RoHS)。关于 National Instruments 中国 RoHS 合规性信息,请登录 ni.com/environment/rohs_china。(For information about China RoHS compliance, go to ni.com/environment/rohs_china.) NI PXIe-2738 Specifications | © National Instruments | 11 Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. © 2014 National Instruments. All rights reserved. 376202A-01 Dec14