MBR1030 - RFE International, Inc.

SCHOT TKY BARRIER RECTIFIER
MBR1020 *Thru MBR1060* 10 Amps
RoHS
FEATURES
• Low power loss, high efficiency
• High current capability, low forward voltage drop
• High surge capability
• For use in low voltage, high frequency inverters,
free wheeling and polarity protection applications
seconds,
• High temperature soldering:260℃/10
0.25”(
6.35mm)from case
MECHANICAL DATA
• Molded plastic body (UL 94V-0 rated)
• Terminals: lead free. solderable per
MIL-STD-750, Method 2026
• Polarity: As marked
• Mounting position: Any
- .max
• Mounting torque: 5 in. lbs
• Weight: 0.08 ounce, 2.24 grams
SUFFIX X
SUFFIX Y
PIN1
PIN1
Case
PIN2
Case
PIN2
TO-220AC
Dimensions in inches and (millimeters)
MAXIMUM RATINGS & ELECTRICAL CHARACTERISTICS
TA= 25℃ unless otherwise specified.
Parameter
Symbol MBR1020* MBR1030* MBR1040* MBR1050* MBR1060* Unit
Maximum Repetitive Peak
VRRM
20
30
40
50
60
V
Reverse Voltage
Maximum DC Blocking Voltage
VDC
20
30
40
50
60
V
Maximum Average Forward
10.0
Rectified Current
IO
A
@ Tc = 125°C
Peak Forward Surge Current
IFSM
250
A
60Hz Half-Sine Wave, 1 Cycle
Forward Voltage Drop
0.55
0.70
@ IF = 10A, Ta = 25°C
VFM
V
@ IF = 10A, Ta = 100°C
Peak DC Reverse Current
0.2
Ma
@ Ta = 25°C
IRM
at rated DC Blocking Voltage
50
@ Ta = 100°C
°C/W
Typical Thermal Resistance
R0JC
3.0
Junction to Lead (Note)
-55 to +125
-55 to +150
Operating Temperature Range
TJ
°C
-55 to +150
Storage Temperature Range
TSTG
°C
NOTE: Thermal Resistance from Junction to lead, with Heatsink Size (2”x3”x0.25”)Al-Plate.
Page 1 of 2
RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail [email protected]
C3SBR7
2013.05.29
SCHOT TKY BARRIER RECTIFIER
MBR1020 Thru MBR1060
10 Amps
RoHS
RATING & CHARACTERISTIC CURVES
FIG.2-MAXIMUM FORWARD CURRENT DERATING
AVERAGE FORWARD CURRENT (A)
MB
PEAK FORWARD SURGE CURRENT (A)
FIG.1-MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
8.3ms Single Half Sine Wave
JEDEC Method
R1
R1
050
MB
60
-10
-10
020
40
NUMBER OF CYCLES AT 60Hz
TJ=25℃
Pulse Width=300us
1% Duty Cycle
MB
R1
0
02
-10
40
MB
R
5
10
0-1
06
0
FIG.4-TYPICAL REVERSE CHARACTERISTICS
INSTANTANEOUS REVERSE CURRENT (uA)
INSTANTANEOUS FORWARD SURGE CURRENT (A)
FIG.3-TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
INSTANTANEOUS FORWARD VOLTAGE (V)
TJ=100℃
TJ=75℃
TJ=25℃
PERCENT OF RATED PEAK REVERSE VOLTAGE (%)
Page 2 of 2
RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail [email protected]