Bulletin 105

Bulletin 105
IEC Reversing Starters
3
Open Type — Eutectic Alloy Overload Relay
Bulletin 105
• Open Type
• Eutectic Alloy Overload
Relay Accepts Class 10,
20, or 30 Heater
Elements
• Compact Design
Attached to a Common
Mounting Plate
Cat. No. 105-C23NDJOV
TABLE OF CONTENTS
Description
Page
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-65
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-89
Description
Page
Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-109
Description
Bulletin 105 enclosed starters use Bulletin 104 reversing contactors and a Bulletin
592 eutectic alloy overload relay on a common mounting plate. Reversing starters
(9 A through 180 A) incorporate a “dual” interlock that provides both mechanical and
electrical interlocking in a single unit. A normally open auxiliary contact is also included
on each contactor.
Conformity to Standards:
CSA 22.2
UL 508
Your order must include:
• Cat. No. of the reversing starter
selected.
• Coil Voltage Code.
• Overload Relay Suffix Code.
3-64
Bulletin 105
IEC Reversing Starters
Product Selection
Open Type — Eutectic Alloy Overload Relay — AC Operated
Reversing Starters with AC Coils — Starters require 3 overload heater elements. See the Industrial Control Catalog for selection
tables.
Ratings (AC3, AC4)
Max
Ie
[A]
kW
3∅
380V/415V
Open Type
HP
1∅
3∅
115V
230V
200V
230V
460V
575V
Cat. No.
9
4
1/3
1
2
2
5
7-1/2
105-C09N⊗JOV
12
5-1/2
1/2
2
3
3
7-1/2
10
105-C12N⊗JOV
16
7-1/2
1
3
5
5
10
15
105-C16N⊗JOV
23
11
2
3
5
7-1/2
15
15
105-C23N⊗JOV
30
15
2
5
7-1/2
10
20
25
105-C30N⊗KOV
37
18-1/2
3
5
10
10
25
30
105-C37N⊗COV
43
22
3
7-1/2
10
15
30
30
105-C43N⊗COV
60
30
5
10
15
20
40
50
105-C60N⊗COV
72
37
5
15
20
25
50
60
105-C72N⊗DOV
110
55
—
—
30
40
75
100
105-B110N⊗DOV
⊗ Coil Voltage Code
The Cat. No. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the Cat. No. Example: Cat. No. 105-C09N⊗JOV
becomes Cat. No. 105-C09NDJOV.
For 105-C Starters
24
48
110
120
208
208…
240
220
240
277
440
480
500
600
50 Hz
—
—
—
—
—
—
A
T
—
N
G
B
—
M
—
60 Hz
—
—
—
—
H
L
—
A
—
—
—
N
B
—
C
Separate Control (without transformer) 50 Hz
Coil Voltage Code
60 Hz
K
Y
D
—
—
—
—
—
—
—
—
—
—
—
—
J
X
—
D
—
—
—
—
T
—
—
—
—
—
—
220
240
277
380
415
440
480
500
600
—
AC Voltage
Common Control
Coil Voltage Code
380… 400…
400
415
For 105-B Starters
24
48
110
120
208
208…
240
50 Hz
—
—
—
—
—
—
A
T
—
N
I
B
—
M
60 Hz
—
—
—
—
H
L
—
A
—
—
—
G
B
—
C
Separate Control (without transformer) 50 Hz
Coil Voltage Code
60 Hz
K
Y
D
—
—
—
—
—
—
—
—
—
—
—
—
J
X
—
D
—
—
—
—
F
—
—
—
—
—
—
AC Voltage
Common Control
Coil Voltage Code
Reversing Starters with DC Coils — Starters require 3 overload heater elements. See the Industrial Control Catalog for selection
tables.
Ratings (AC3, AC4)
Max
Ie
[A]
kW
3∅
380V/415V
Open Type
HP
1∅
115V
3∅
230V
200V
230V
460V
575V
Cat. No.
9
4
1/3
1
2
2
5
7-1/2
105-C09NZ⊗JOV
12
5-1/2
1/2
2
3
3
7-1/2
10
105-C12NZ⊗JOV
16
7-1/2
—
3
5
5
10
15
105-C16NZ⊗JOV
23
11
—
3
5
7-1/2
15
15
105-C23NZ⊗JOV
30
15
2
5
7-1/2
10
20
25
105-C30NZ⊗KOV
37
18-1/2
3
5
10
10
25
30
105-C37NZ⊗COV
43
22
—
—
10
15
30
30
105-C43NZ⊗COV
60
30
5
10
15
20
40
40
105-C60ND⊗COV
72
37
5
10
20
25
50
50
105-C72ND⊗DOV
110
55
—
—
30
40
75
100
105-B110NZ⊗DOV
⊗ Coil Voltage Code
The Cat. No. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the Cat. No. Example: Cat. No. 105-C09NZ⊗JOV
becomes Cat. No. 105-C09NZJJOV.
12V
24V
48V
64V
80V
115V
125V
230V
105-C Starter Coil Voltage Code
DC Voltage
Q
J
Y
B
E
P
S
F
250V
T
105-B110 Starter Coil Voltage Code
12
24
48
64
80
01
03
23
25
Accessories — Page 3-89
Approximate Dimensions — Page 3-109
3-65