Bulletin 112

Bulletin 112
IEC Combination Starters
3
Fusible and Non-Fusible Disconnect Type
Bulletin 112
Cat. No. 112-C09FBA1F-1-7
IP66 (Type 3,4,12) Metal Enclosure with Hinged Cover
• Compact Design
• Can Be Modified in
the Field
• Selection of Enclosures
IP42 (Type 1) and
IP66 (Type 3/4/12)
• Bimetallic Class 10
Overload Relays
• Solid-State Overload
Relays
• Fusible or Non-Fusible
Versions
• Handle with Defeater
Mechanism
• Padlockable Handle with
up to Three Padlocks
TABLE OF CONTENTS
Description
Page
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-75
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-89
Description
Page
Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-100
Approximate Dimensions . . . . . . . . . . . . . . . . . . . . 3-105 and 3-108
Description
Bulletin 112 is the first true IEC combination starter on the market, in that the enclosure
and components have been designed to specific IEC standard requirements. The
Bulletin 112 combination starter consists of a Bulletin 100 Contactor, Bulletin 193
bimetallic (Class 10) or solid-state overload relay and Bulletin 194R fused disconnect
switch installed in a common enclosure. These full-voltage combination starters are
designed to provide the disconnecting means, short-circuit protection (with suitable
fuses), control and overload protection for three-phase squirrel-cage motors. All
starters include a normally open auxiliary contact as standard.
Conformity to Standards:
Approvals:
IEC 947
VDE 0660
CSA 22.2
UL 508
cUL US
A-B EXPRESS
Fast Shipment Program
• Fast shipment of Bulletin 112 IEC
Products to satisfy your unexpected
demands.
• Make your selections from any of the
Cat. Nos. printed in blue and identify
your order as
Your order must include:
• Cat. No. of the combination starter
selected.
• Coil Voltage Code.
• Overload Relay Suffix Code.
• If required, factory-installed
modifications suffix code.
• If required, Cat. No. of any accessories.
3-74
Bulletin 112
IEC Combination Starters
Product Selection
Fusible Disconnect Type
Fast Shipment Program Cat. Nos. are printed in blue.
AC Operated
Ratings (AC3, AC4)
HP
Max
Ie
[A]
3∅
200V
230V
460V
575V
Fuse Clip
Rating
Amperes/
UL Class
IP42 (Type 1)
General Purpose
Sheet Metal Enclosure
(Hinged Cover)
IP66 (Type 3/4/12)
Watertight, Dusttight
Sheet Metal Enclosure
(Hinged Cover)
Cat. No.
Cat. No.
9
2
2
5
7-1/2
30A/Class CC
112-C09A⊗✪
112-C09F⊗✪
12
3
3
7-1/2
10
30A/Class J
112-C12A⊗✪
112-C12F⊗✪
23
5
7-1/2
15
15
30A/Class J
112-C23A⊗✪
112-C23F⊗✪
30
7-1/2
10
20
25
60A/Class J
112-C30A⊗✪
112-C30F⊗✪
43
10
15
30
30
60A/Class J
112-C43A⊗✪
112-C43F⊗✪
60
15
20
40
50
100A/Class J
112-C60A⊗✪
112-C60F⊗✪
72
20
25
50
60
100A/Class J
112-C72A⊗✪
112-C72F⊗✪
110
30
40
75
100
200A/Class J
112-B110A⊗✪
112-B110F⊗✪
180
50
60
125
150
200A/Class J
112-A180A⊗✪
112-A180F⊗✪
180
60
—
150
—
400A/Class J
112-B180A⊗✪
112-B180F⊗✪
250
75
100
200
250
400A/Class J
112-B250A⊗✪
112-B250F⊗✪
300
100
100
250
300
400A/Class J
112-B300A⊗✪
112-B300F⊗✪
⊗ Coil Voltage Code
The Cat. No. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the Cat. No. Example: Cat. No. 112-C09A⊗✪
becomes Cat. No. 112-C09AB✪.
Voltage
Common Control ➊
Coil Voltage Code
120V — Separate Control (without transformer)
Coil Voltage Code
208V
230…240V
460…480V
575…600V
H
A
B
C
D
D
D
D
60 Hz
✪ Overload Relay Code
The Cat. No. as listed is incomplete. Select an overload relay code from page 3-87 or 3-88 to complete the Cat. No.
➊ When selecting a factory-installed control circuit transformer (see Modifications page 3-98), use the Common Control Coil Voltage Code to denote
the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No.
112-C09FB-✪-6P will have a transformer with a 480V primary/120V secondary and a 120V starter coil. If a starter coil voltage other than 120V
is desired, a second Coil Voltage Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 112-C09FBJ-✪-6P
will have a transformer with a 480V primary/24V secondary and a 24V starter coil
Accessories — Page 3-89
Modifications — Page 3-100
Approximate Dimensions — Page 3-105 and 3-108
3-75
Bulletin 112
IEC Combination Starters
Product Selection, Continued
Non-Fusible Disconnect Type
Fast Shipment Program Cat. Nos. are printed in blue.
AC Operated
Ratings (AC3, AC4)
HP
Max
Ie
[A]
IP42 (Type 1)
General Purpose
Sheet Metal Enclosure
(Hinged Cover)
IP66 (Type 3/4/12)
Watertight, Dusttight
Sheet Metal Enclosure
(Hinged Cover)
Cat. No.
Cat. No.
3∅
200V
230V
460V
575V
9
2
2
5
7-1/2
112-C09A⊗✪-DNF
112-C09F⊗✪-DNF
12
3
3
7-1/2
10
112-C12A⊗✪-DNF
112-C12F⊗✪-DNF
23
5
7-1/2
15
15
112-C23A⊗✪-DNF
112-C23F⊗✪-DNF
30
7-1/2
10
20
25
112-C30A⊗✪-DNF
112-C30F⊗✪-DNF
43
10
15
30
30
112-C43A⊗✪-DNF
112-C43F⊗✪-DNF
60
15
20
40
50
112-C60A⊗✪-DNF
112-C60F⊗✪-DNF
72
20
25
50
60
112-C72A⊗✪-DNF
112-C72F⊗✪-DNF
110
30
40
75
100
112-B110A⊗✪-DNF
112-B110F⊗✪-DNF
180
50
60
125
150
112-A180A⊗✪-DNF
112-A180F⊗✪-DNF
180
60
—
150
—
112-B180A⊗✪-DNF
112-B180F⊗✪-DNF
250
75
100
200
250
112-B250A⊗✪-DNF
112-B250F⊗✪-DNF
300
100
100
250
300
112-B300A⊗✪-DNF
112-B300F⊗✪-DNF
⊗ Coil Voltage Code
The Cat. No. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the Cat. No. Example:
Cat. No. 112-C09A⊗✪-DNF becomes Cat. No. 112-C09AB✪-DNF.
Voltage
Common Control ➊
Coil Voltage Code
120V — Separate Control (without transformer)
Coil Voltage Code
208V
230…240V
460…480V
575…600V
H
A
B
C
AD
AD
CD
CD
60 Hz
✪ Overload Relay Code
The Cat. No. as listed is incomplete. Select an overload relay code from page 3-87 or 3-88 to complete the Cat. No.
➊ When selecting a factory-installed control circuit transformer (see Modifications page 3-98), use the Common Control Coil Voltage Code to denote
the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example:
Cat. No. 112-C09FB-✪-DNF-6P will have a transformer with a 480V primary/120V secondary and a 120V starter coil. If a starter coil voltage
other than 120V is desired, a second Coil Voltage Code must be added to denote the coil/transformer secondary voltage. Example:
Cat. No. 112-C09FBJ-✪-DNF-6P will have a transformer with a 480V primary/24V secondary and a 24V starter coil.
Accessories — Page 3-89
Modifications — Page 3-100
Approximate Dimensions — Page 3-105 and 3-108
3-76