sabre datasheet

ELITEELITE-L Series
ELITE - Low Voltage / Dry contact
Remote Control System
Applications
•
Garden Lighting
Pond pumps
• Remote outdoor Switching
•
•
Access control
•
Industrial control
Features
• 4 switched channels
1000W rated
• 250/1000m range
• 12-32Vac/dc and 230Vac
supply
• Completely waterproof
ABS enclosure (IP68)
• All outputs momentary,
latching or timed
• Any switch maps to any
relay or multiple relays
• 868MHz Reliable FM
Technology
Description
Whatever your switching application the ELITE Remote control system;
with 4 individual relay switches and a completely waterproof IP68 enclosure;
will be a great choice.
The ELITE remote control system has been designed with the
requirements of electricians in mind and therefore it can be used to switch all
lighting types as well as other applications such as Water Features, Electric
gates and Garage Doors.
Each receiver has 4 switched outputs. Using our one touch ‘easy-learn’
process each relay can be controlled from any switch on any compatible
transmitter.
• EMC Compliant for Europe
• 10 Cable entry points for
easy installation.
Thanks to the latest technology each of the 4 outputs on the ELITE remote
control system can be set to operate in a timed, momentary or latching
mode for complete flexibility.
DS-ELITE-L-3
ELITE Low Voltage / Dry Contact Remote control System
System Part Numbering
Part Number
Description
System 4 outputs
ELITE-S4L
With ELITE-T8
System 4 outputs
ELITE-XS4L
With ELITE-XT6
ELITE-RXL
Additional Transmitters
Receiver 4 output
Receiver
Power Supply
Range**
(Metres)
230Vac
250
230Vac
12-32Vac/dc
1000m
230Vac
12-32Vac/dc
-
**Range stated is opmum - Line of Sight. Range can be hugely
reduced by obstacles
Transmitters ship with: Wall Mounting Cradle and Lanyard
ELITE-X Series 1000m Range Transmitters
Part Number
Description
ELITE-XT1
Transmitter 1 switch
ELITE-XT2
Transmitter 2 switch
ELITE-XT4
Transmitter 4 switch
ELITE-XT6
Transmitter 4 Switch + All ON/OFF
ELITE-XT8
Transmitter 8 switch
ELITE-XT16
Transmitter 16 switch (8Sw + Shift Key)
FIREFLY-TX-IPKIT
’O’ Ring, Seals Transmitter to IP68
Transmitter dimensions and details on page 7
ELITE Series 250m Range Transmitters
Part Number
Description
ELITE-T8
Transmitter 8 Switch + All ON/OFF
Transmitter dimensions and details on page 7
DS-ELITE-L-3
PAGE 2
ELITE Low Voltage / Dry Contact Remote control System
DS-ELITE-L-3
PAGE 3
ELITE Low Voltage / Dry Contact Remote control System
Quick Installation Guide (systems only)
The Elite system provides 4 switches each capable of switching up to 1.2KW (5A @ 230V). Each channel is
independent and separately controlled. The ELITE-L series Remote control system provides switched contacts
and can therefore be used to switch most voltages be they AC or DC (see maximums on page 7)
1.
2.
3.
4.
5.
6.
7.
8.
9.
Screw the antenna into the terminal (shown as ANT) through the top of the enclosure. Tighten the
antenna to ensure a good seal - “finger tight” is sufficient, no tools should be used.
Mount the ELITE system receiver box in the wall in your desired location (see Page 8 for wall
mounting dimensions and information).
Open the enclosure by removing fixing screws from the enclosure front and then removing the front
from the enclosure.
Wire either MAINS, LIVE, Neutral and Earth connections to the power supply screw terminal as shown
below (shown as A). Or wire 12-32Vac or 12-32Vdc to the low voltage terminals. (shown as B)
Wire your desired connections to the relay switches (shown as C)
Once all required wiring is complete, use the handheld ELITE transmitter to switch the outputs on and
off.
As supplied, the handheld will operate the outputs - Button 1 to output 1, Button 2 to output 2 etc.
All buttons will operate in a latching mode - Press for on, press again for off. It is possible to change the
operation to momentary mode by fitting the links (shown as D)
For advanced operation such as adding extra transmitters different button mapping options see
Fig 1.1
DS-ELITE-L-3
PAGE 4
ELITE Low Voltage / Dry Contact Remote control System
Advanced operation
The ELITE system comes with one transmitter, this is already SYNC’ed and will
operate the system out of the box.
To AUTO-SYNC a new transmitter
1.
To SYNC a new ELITE handheld transmitter to the receiver box - simply press the SYNC button on the
ELITE receiver board. (see page 3 for button locations)
2.
The ELITE receiver will flash all of its relay output LEDs at a high rate to show that it is ready for AUTO
-SYNC.
3.
Press ANY button on the transmitter handheld that you wish to SYNC to the receiver.
4.
All flashing LEDs will go out, the SYNC LED will flash quickly for 2 seconds then go out.
5.
The ELITE receiver will then exit SYNC mode and return to normal operating mode - you may now use
the transmitter to switch the outputs.
NOTE: Maximum 31 handhelds can be auto sync’ed.
MANUAL-SYNC individual transmitter buttons (advanced)
1.
To SYNC a specific ELITE handheld transmitter button to a specific output on the ELITE receiver box press the SYNC button on the ELITE receiver board. (see page 3 for button locations).
2.
The ELITE receiver will flash all its relay output LEDs at a high rate to show that it is ready for SYNC.
3.
Press the SYNC button again - the ELITE receiver will flash output LED 1 only - this is showing that output 1 is selected. Pressing the SYNC button again will select output 2 and so on, through to output 4.
4.
Once you have selected the required output (that output LED only is flashing) press the SPECIFIC
button on the transmitter handheld that you wish to SYNC to the receiver.
5.
The flashing LEDs will go out, the SYNC LED will flash quickly for 2 seconds then go out.
NOTE: After a successful pairing the Elite-RX will exit SYNC mode automatically.
You cannot perform a SYNC ALL and a MANUAL SYNC on a single transmitter.
Maximum of 31 BUTTONS can be auto sync’ed
Erasing ALL transmitters:
1.
2.
3.
4.
Open the case and apply power
Press and hold the ERASE button for 10 seconds
All relay LEDs flash together and then go out
Erase complete, you can now follow the pairing process to pair your transmitters to the receiver.
ERASE Individual Transmitters:
1.
2.
3.
4.
5.
6.
Open the case and apply power
Press and release the ERASE button
The LED next to ERASE should remain lit and all relay LEDs will be flashing
Press any button on the transmitter to be erased
All output LEDs will go out to show that the transmitter has been erased
The ELITE will exit to normal operating mode
Setting MOMENTARY / LATCHING links
It is possible to set the relay switches on the ELITE receiver to either momentary or latching operation
(Latching - one press for on, one press for off, Momentary - On while button is held only)
1.
The Momentary/Latching Setting links are in the position shown as (D) on page 4.
2.
To set a relay switch to momentary choose the associated link cap:
Link fitted - MOMENTARY
Link Removed - LATCHING
4.
Re-apply the power to the ELITE-RX.
Continued overleaf...
DS-ELITE-L-3
PAGE 5
ELITE Low Voltage / Dry Contact Remote control System
Advanced operation continued…
TEST MODE
The ELITE comes with an in-built test mode which allows a user to check the signal strength of any
compatible handheld:
1.
Press the TEST button on the PCB (see page 3 for button locations)
2.
Press any button/activate the transmitter which you want to test
3.
LEDs 1-8 will show a bar graph of the signal strength - the more LEDs flashing, the better the signal.
4.
To exit test mode - press test again.
Notes:
- When in test mode the receiver still operates relays as normal.
- For reliable communications please ensure at least 3 LED’s are lit.
- Try the transmitter in the location where it will be used to make sure it will work once
installation complete.
TIMER SELECT MODE
Note: As default all timers are set to 0 seconds.
The ELITE has a timer option which can be set individually on each output. Meaning that you can set any
output to de-activate after a different amount of time should you wish to.
1.
To enter timer select mode - Press the TIMER button
2.
Select your chosen output by pressing the TIMER button to scroll through each relay in turn
3.
As soon as the LED for the required output stops flashing tap the TIMER button again
4.
Each tap of the timer button will increase the timer delay in line with the table below
0 LED
0s
1 LED
½s
2 LED
5s
3 LED
10s
4 LED
30s
5 LED
1m
6 LED
10m
7 LED
30m
8 LED
1hr
5.
When you have selected the required delay stop tapping and, wait 3 seconds.
6.
The Red TIMER LED will flash to show that the setting is saved
Note: Settings are saved even after power is removed.
NOTE: When zero LED’s are lit the relays will operate as per the Momentary/latching links.
TIMERS and MOMENTARY/LATCHING setting links
1.
2.
When the momentary/latching setting link for a relay is set to MOMENTARY the timer will restart its
count down every time a button is pressed.
When the momentary/latching setting link for a relay is set to LATCHING, the relay will turn ON/OFF
with each button press. If the relay is left ON it will turn off after the timer period expires.
Erasing ALL Timers:
1.
2.
3.
4.
5.
Open the case and apply power
Press and hold the TIMER button for 10 seconds,
A single relay LED will be flashing
When all Relay LED flash together and then go out the timer erase process is complete.
All relays will operate as per their jumper settings.
DS-ELITE-L-3
PAGE 6
ELITE Low Voltage / Dry Contact Remote control System
Technical Specifications
Transmitters: ELITE-T8
Enclosure Rating: Not waterproofed
Battery Type:
CR2032 (supplied)
Battery Life:
3 years @ approx 50 1/2second presses p/day
Dimensions:
86 x 54 x 7 mm
Changing the Battery: Carefully squeeze in the battery lock tab on the base of the transmitter, and then pull out
the battery tray
Electrical Characteristics
Supply Voltage
Frequency:
RF Output Power (ERP) @ 86MHz
Min
Typical
-
3
869.500
3
Max
Units
V
MHz
mW
Transmitters: ELITE-XTn
Enclosure Rating: Standard IP68
Battery Type:
3 x AAA (supplied)
Battery Life:
5 years @ approx. 50 1/2second presses p/day
Dimensions:
90 x 54 x 27 mm
Changing the Batteries: Remove the six fixing screws. Remove the 2 battery compartment screws, remove the
battery compartment and replace batteries inside it, taking care not to damage cables and ensuring correct battery
polarity
Electrical Characteristics
Supply Voltage
Frequency:
RF Output Power (ERP) @ 869.50MHz
Min
Typical
4.5
869.500
-
100
Max
Units
V
MHz
mW
Receiver Decoder: ELITE-RXL
Enclosure Rating:
IP68
Dimensions:
267 x 148 x 78 mm (not including antenna)
Storage Temperature:
-10 to +70o Celsius.
Operating Temperature: -10 to +50o Celsius.
ELECTRICAL CHARACTERISTICS
Supply Voltage for MAINS
Supply voltage for LOW VOLTAGE
MIN
12V
Relay Rating* (230Vac) RLY1-4
Supply Current :
TYPICAL
230Vac
24
MAX
+10%
32
DIMENSION
Vac
Vac/Vdc
5
Quiescent
All relays operating*
25
90
30
120
A(rms)
60
170
mA
Time delay from Tx on Switch to Rx Relay operation
30
mS
Time delay from Tx sw relax to Rx Relay release
30
mS
*The relay contacts in this unit are for functional use only and must not be used for isolation purposes
Approvals Information:
•
•
•
All RF Solutions products are manufactured in accordance with our ISO:9001 Quality System
ELITE Systems are manufactured to CE standards
Further information available on request.
DS-ELITE-L-3
PAGE 7
ELITE Remote control System
Wall Mounting template (not to scale)
RF Solutions Ltd. Recycling Notice
Meets the following EC Directives:
DO NOT
Discard with normal waste, please recycle.
ROHS Directive 2002/95/EC
Specifies certain limits for hazardous substances.
WEEE Directive 2002/96/EC
Waste electrical & electronic equipment. This product must be
disposed of through a licensed WEEE collection point. RF Solutions Ltd., fulfills its WEEE obligations by membership of an
approved compliance scheme.
Waste Batteries and Accumulators
Directive 2006/66/EC
Where batteries are fitted, before recycling the
product, the batteries must be
removed and disposed of at a licensed
collection point.
Environment Agency producer registration number: WEE/JB0104WV.
Information contained in this document is believed to be accurate, however no representation or warranty is given and R.F. Solutions Ltd.
assumes no liability with respect to the accuracy of such information. Use of R.F.Solutions as critical components in life support systems is
not authorised except with express written approval from R.F.Solutions Ltd.