RFSOLUTIONS DS-ELITE-1

ELITE Series
Professional Remote Control Systems
Applications
•
Garden Lighting
Pond pumps
• Remote outdoor
•
Switching
•
Access control
•
Industrial control
Features
• 4 switched channels
1000W rated
• Systems with 250m or
1000m range
• 230Vac supply
• Completely waterproof ABS
enclosure (IP68)
• All outputs momentary,
latching or timed
• Any switch maps to any switch
or multiple switches
• Systems supplied ’ready to go’
Description
Whatever your switching application the ELITE Remote control system
with 4 individual 230V outputs and it’s completely waterproof IP68 enclosure
will be a great choice.
The ELITE remote control system has been designed with the
requirements of electricians in mind and therefore it can be used to switch all
lighting types as well as other applications such as Water Features, Electric
gates and Garage Doors.
• 868MHz Reliable FM
Technology
• EMC Compliant for Europe
• 10 Cable entry points for easy
installation.
Each receiver has 4 switched outputs. Using our one touch ‘easy-learn’ process each relay can be controlled from any switch on any compatible transmitter.
Thanks to the latest technology each of the 4 outputs on the ELITE remote
control system can be set to operate in a timed, momentary or latching
mode allowing for complete flexibility.
DS-ELITE-1
ELITE Remote control System
System Part Numbering
Part Number
Description
Receiver
Power Supply
Range**
(Metres)
ELITE-S4
System 4 outputs
230Vac
250
ELITE-XS4
System 4 outputs
230Vac
1000m
ELITE-RX
Receiver 4 output
230Vac
-
**Range stated is optimum—Line of Sight
Additional Transmitters
Transmitters ship with: Wall Mounting Cradle and Lanyard
ELITE-X Series 2000m Range Transmitters
Part Number
Description
ELITE-XT1
Transmitter 1 switch
ELITE-XT2
Transmitter 2 switch
ELITE-XT4
Transmitter 4 switch
ELITE-XT6
Transmitter 4 Switch + All ON/OFF
ELITE-XT8
Transmitter 8 switch
ELITE-XT16
Transmitter 16 switch (8Sw + Shift Key)
FIREFLY-TX-IPKIT
’O’ Ring, Seals Transmitter to IP68
Transmitter dimensions and details on page 7
ELITE Series 250m Range Transmitters
Part Number
Description
ELITE-T6
Transmitter 4 Switch + All ON/OFF
Transmitter dimensions and details on page 7
DS-ELITE-1
PAGE 2
ELITE Remote control System
DS-ELITE-1
PAGE 3
ELITE Remote control System
Quick Installation Guide (systems only)
The Elite system provides 4 switches each capable of switching up to 1KW (4A @ 230V). Each channel is independent and separately fused. The ELITE Remote control system provides 230V mains switched outputs via
each terminal.
1.
2.
3.
4.
5.
6.
7.
8.
First mount the ELITE system receiver box in the wall in your desired location (see Page 7 for wall
mounting dimensions and information).
Open the enclosure by removing fixing screws from the enclosure front and then removing the front
from the enclosure.
Wire the LIVE Neutral and Earth connections to the power supply screw terminal as shown below
(shown as A).
Wire your load(s) as required (shown as B)
Once all required wiring is complete, use the handheld ELITE transmitter to switch the outputs on and
off.
As supplied the handheld will operate the outputs - Button 1 to output 1, Button 2 to output 2 etc.
All buttons will operate in a latching mode - Press for on, press again for off. It is possible to change the
operation to momentary mode by fitting the links (shown as C)
For advanced operation such as adding extra transmitters different button mapping options see advanced operation section.
Fig 1.1
DS-ELITE-1
PAGE 4
ELITE Remote control System
Advanced operation
The ELITE system comes with one transmitter, this is already SYNC’ed and will
operate the system out of the box.
To AUTO-SNYC a new transmitter
1.
To SYNC a new ELITE handheld transmitter to the receiver box - simply press the SNYC button on the
ELITE receiver board. (see page 3 for button locations)
2.
The ELITE receiver will flash all of its relay output LEDs at a high rate to show that it is ready for
AUTO-SYNC.
3.
Press ANY button on the transmitter handheld that you wish to SNYC to the receiver.
4.
All flashing LEDs will go out, LED 8 will flash quickly for 2 seconds then go out.
5.
The ELITE receiver will then exit SYNC mode and return to normal operating mode - you may now use
the transmitter to switch the outputs.
MANUAL-SYNC individual transmitter buttons (advanced)
1.
2.
3.
4.
5.
To SYNC a specific ELITE handheld transmitter button to a specific output on the ELITE receiver box press the SNYC button on the ELITE receiver board. (see page 3 for button locations).
The ELITE receiver will flash all its relay output LEDs at a high rate to show that it is ready for SYNC.
Press the SYNC button again - the ELITE receiver will flash output LED 1 only - this is showing that output 1 is selected. Pressing the SYNC button again will select output 2 and so on to output 4.
Once you have selected the required output (that output LED only is flashing) press ANY button on the
transmitter handheld that you wish to SNYC to the receiver.
The flashing LEDs will go out, LED 8 will flash quickly for 2 seconds then go out.
NOTE: After a successful pairing the Elite-RX will exit SYNC mode automatically.
You cannot SYNC ALL and MANUAL SYNC a single transmitter.
Erasing ALL transmitters:
1.
2.
3.
4.
Open the case and apply power
Press and hold the ERASE button for 10 seconds
All relay LEDs flash together and then go out
Erase complete, you can now follow the pairing process to pair your transmitters to the receiver.
ERASE Individual Transmitters:
1.
2.
3.
4.
5.
6.
Open the case and apply power
Press and release the ERASE button
The LED next to ERASE should remain lit and all relay LEDs will be flashing
Press any button on the transmitter to be erased
All output LEDs will go out to show that the transmitter has been erased
The ELITE will exit to normal operating mode
Erasing ALL Timers:
1.
2.
3.
4.
5.
Open the case and apply power
Press and hold the TIMER button for 10 seconds,
A single relay LED will be flashing
When all Relay LED flash together and then go out the timer erase process is complete.
All relays will operate as per their jumper settings.
DS-ELITE-1
PAGE 5
ELITE Remote control System
Advanced operation continued…
Installation TEST MODE
The ELITE comes with an in-built test mode which allows a user to check the signal strength of any
compatible handheld:
1.
Press the SIGNAL TEST button on the PCB
2.
Press any button/activate the transmitter which you want to test
3.
LEDs 1-8 will show a bar graph of the signal strength - the more LEDs on the better the signal
TIP: Try the transmitter in the location where it will be used to make sure it will work once installation is complete.
Note: When in test mode and paired transmitter will still activate its relay.
For reliable communications please ensure at least 3 LED’s are lit.
Installation TIMER SELECT MODE
NOTE: As default all timers are set to 0 seconds.
The ELITE has a timer option which can be set individually on each output. Meaning that you can set any output to de-activate after a different amount of time should you wish
1.
To enter timer select mode - Press the TIMER SELECT button
2.
Select your chosen output by pressing the TIMER SELECT button to scroll through each relay in turn
3.
When the LED for the required output is flashing wait until it becomes solidly LIT
4.
Press the TIMER SELECT button again to increase the timer delay in line with the table belo
5.
When you have selected the required delay, wait 3 seconds. All Red LEDs will flash to show that the setting is saved
0 LED
1 LED
2 LED
3 LED
4 LED
5 LED
6 LED
7 LED
8 LED
0s
½s
5s
10s
30s
1m
10m
30m
1hr
Note: Settings are saved even after power is removed.
When zero LED’s are lit the relays will operate as per the jumper links. Momentary or latching.
Setting MOMENTARY / LATCHING links
NOTE: As default all relay switches are latching.
It is possible to set the relay switches on the ELITE receiver to either momentary or latching operation
(Latching - one press for on, one press for off, Momentary - On while button is held only)
1.
Remove all power from the receiver and then open the ELITE-RX receiver enclosure. Unscrew the antenna and slide out the PCB.
2.
The Momentary/Latching Setting links are in the position shown as (C) page 4.
3.
To set a relay switch to momentary, simply set the links as per the below table for the appropriate relay
switch.
4.
Re-assemble the ELITE-RX and re-apply the power.
DS-ELITE-1
PAGE 6
ELITE Remote control System
Technical Specifications
Transmitters: ELITE-Tn
Enclosure Rating: Not waterproofed
Battery Type:
CR2032 (supplied)
Battery Life:
3 years @ approx 50 1/2second presses p/day
Dimensions:
86 x 54 x 7 mm
Changing the Battery: Carefully squeeze in the battery lock tab on the base of the transmitter, and then pull out
the battery tray
Electrical Characteristics
Min
Typical
Supply Voltage
Frequency:
RF Output Power (ERP) @ 868 MHz
Max
Units
3V
V
869.500
MHz
3
mW
-
Transmitters: ELITE-Xn
Enclosure Rating: Standard IPx8
Battery Type:
3 x AAA (supplied)
Battery Life:
5 years @ approx. 50 1/2second presses p/day
Dimensions:
90 x 54 x 27 mm
Changing the Battery: Remove the six fixing screws. Remove 2 battery compartment screws and replace batteries, taking care of cables and battery polarity
Electrical Characteristics
Supply Voltage
Min
Typical
4.5V
Frequency:
Max
Units
V
869.500
RF Output Power (ERP) @ 868 MHz
-
50
MHz
100mW
mW
Receiver Decoder: ELITE-RX
Enclosure Rating:
IP68
Dimensions:
267 x 148 x 78 mm (not including antenna)
Storage Temperature:
-10 to +70o Celsius.
Operating Temperature: -10 to +50o Celsius.
ELECTRICAL CHARACTERISTICS
MIN
Supply Voltage for +230 VAC
TYPICAL
MAX
DIMENSION
230Vac
Relay Rating* (230Vac) RLY1-4
5rms
Supply Current :
40
140
Quiescent
All relays operating*
Time delay from Tx on Switch to Rx Relay operation
Time delay from Tx sw relax to Rx Relay release
VDC
12peak
A
30
mA
mS
30
mS
*The relay contacts in this unit are for functional use only and must not be used for isolation purposes
Approvals Information:
•
•
•
All RF Solutions products are manufactured in accordance with our ISO:9001 Quality System
ELITE Systems are manufactured to CE standards
Further information available on request.
DS-ELITE-1
PAGE 7
ELITE Remote control System
Wall Mounting template (not to scale)
RF Solutions Ltd. Recycling Notice
Meets the following EC Directives:
DO NOT
Discard with normal waste, please recycle.
ROHS Directive 2002/95/EC
Specifies certain limits for hazardous substances.
WEEE Directive 2002/96/EC
Waste electrical & electronic equipment. This product must be
disposed of through a licensed WEEE collection point. RF Solutions Ltd., fulfills its WEEE obligations by membership of an
approved compliance scheme.
Waste Batteries and Accumulators
Directive 2006/66/EC
Where batteries are fitted, before recycling the
product, the batteries must be
removed and disposed of at a licensed
collection point.
Environment Agency producer registration number: WEE/JB0104WV.
Information contained in this document is believed to be accurate, however no representation or warranty is given and R.F. Solutions Ltd.
assumes no liability with respect to the accuracy of such information. Use of R.F.Solutions as critical components in life support systems is
not authorised except with express written approval from R.F.Solutions Ltd.