RFMD FIREFLY-TX16

VIPER Remote Control Systems
•
433MHz FM Technology
•
1 – 4 Channels each 1000W Rated
•
upto 150metres Range
•
12-30Vdc / 230Vac supply
•
Waterproof (IP68)
•
High Security RF Protocol
•
4 Relays 5A @ 230Vac
•
Outputs Momentary or Latching
•
Any Switch Map to Any Relay
Output
•
Systems supplied ’ready to Go’
•
EMC / FCC Compliant for Europe /
USA
Applications
•
General Purpose Remote Switching
•
Garage Doors
•
Electric Gates, Shutters
•
All known Lighting types (LED, fluorescent, halogen,
tungsten, xenon; basically all lighting types).
•
Access Control
Description
Housed in a rugged IP68 weatherproof enclosure, The VIPER system is ideally suited
to any outside Remote switch requirement.
Each receiver has 4 relays, using the ‘easy-learn’ process each relay can be controlled
from any switch on any transmitter.
Installation is by screw terminals to the power supply, and the output relay contacts.
The output relays are activated by the button press on the transmitter encoder.
DS VIPER-2
©2009 REG No 277 4001, Lewes, England. Page 1
VIPER Remote Control Systems
Systems Part Numbers
Operating from 12-30Vdc
Receiver
Range**
System 1 channel
Power Supply
12-30Vdc
(Metres)
150
VIPER-S2
System 2 channel
12-30Vdc
150
VIPER-S4
System 4 channel
12-30Vdc
150
Part Number
Description
VIPER-S1
Systems Operating from 230Vac (see DS-VIPERMAINS)
Receiver
Range**
System 1 channel
Power Supply
230Vac
(Metres)
150
System 2 channel
230Vac
150
Part Number
Description
VIPER-S1M
VIPER-S2M
**Range stated is optimum, direct line of sight. In worst conditions this can be reduced by over 50%
Additional Transmitters
Transmitters ship with;
Wall Mounting Cradle,
Part Number
Description
FIREFLY-TX1
Transmitter 1 switch
FIREFLY-TX2
Transmitter 2 switch
FIREFLY-TX4
Transmitter 4 switch
FIREFLY-TX8
Transmitter 8 switch
FIREFLY-TX16
Transmitter 16 switch (8Sw + Shift Key)
FIREFLY -TX-IPKIT
’O’ Ring, Seals Transmitter to IP68
Custom Version
To create a custom version requires just a Sticker!
Please contact Sales for further info.
DS VIPER-2
and Lanyard
©2009 REG No 277 4001, Lewes, England. Page 2
VIPER Remote Control Systems
Data Outputs
Each output relay provides an isolated switch. Connections are Common (COM), Normally Open (NO) and
Normally Closed (NC).
NC
COM
NO
NC
COM
NO
Relay Connections when
Transmitter NOT Operating
Relay Connections when
Transmitter OPERATING
Installation
Below is a simple example showing one possible way to wire a relay in order to give switched power
to an external load:
When the relay is energised the ‘COM’ connects to ’NO’ and power is applied to the Load.
R F Solutions Ltd.,
Unit 21, Cliffe Industrial Estate,
Lewes, E. Sussex. BN8 6JL. England.
Email : [email protected]
Tel: +44 (0)1273 898 000
DS VIPER-2
http://www.rfsolutions.co.uk
Fax: +44 (0)1273 480 661
©2009 REG No 277 4001, Lewes, England. Page 3
VIPER Remote Control Systems
Pairing a Transmitter to a Receiver
Each transmitter has a unique identity. Each time a transmitter Switch is operated, it emits a secure
RF signal. The Receiver can learn this signal and allocate to any of its outputs.
The only limitation is that each receiver has a maximum memory for upto 40 pairings, these can be from
the same or any number of transmitters.
Hint: the same transmitter may be taught to different receivers to create ‘master keys’.
VIPERVIPER-S1 / VIPERVIPER-S2 / VIPERVIPER-S3 (12(12-30Vdc Receivers)
To Learn a New Transmitter switch follow this procedure
Any transmitter button can be learnt to one or many of the receiver output relays.
Each button must be learnt to each relay individually by following this procedure:
1.
Select the receiver output relay to learn to:
2.
Briefly press the receiver Learn switch (S2) once
3.
The Learn LED will flash once to indicate output relay 1 is selected
4.
After the LED stops flashing, press the Learn switch again to select the next relay channel
5.
Repeat step 2 until the required output relay is selected.
6.
Press the button on the transmitter you want to learn to the relay output.
7.
The Learn LED will then illuminate, press the same transmitter button again.
8.
The Learn LED will then flash to indicate learning is complete.
9.
The transmitter button will now operate the relay.
Erasing Receivers Memory
1.
Press and hold the receiver Learn Switch for approx 10 seconds.
2.
When the Learn LED turns OFF all memory is erased
NOTE: You cannot erase individual Tx encoders
Configuring Receiver Outputs
The jumper links configure the outputs to be Momentary or Latching.
The jumper links are made / removed by the small link ‘cap’ placed over the pin header.
Link Positions
LK1
LK2
Closed
Closed
RLY 1
Mom
Relay Outputs
RLY 2
RLY 3
Mom
Mom
RLY 4
Mom
Closed
Open
Mom
Mom
Latch
Latch
Open
Open
Closed
Mom
Latch
Latch
Latch
Open
Latch
Latch
Latch
Latch
(The configuration shown in the picture above represents the third row of the table)
DS VIPER-2
©2009 REG No 277 4001, Lewes, England. Page 4
VIPER Remote Control Systems
VIPERVIPER-S1M / VIPER S2M (230Vac Powered Receivers)
Please Note: During Learn and Erase the relays operate at high speed. They should be isolated from sensitive equipment during this process.
To Pair a Transmitter button to receiver Output Relay #1
1.
Apply power the receiver and wait 10secs for the unit to enter ‘normal operation’ mode.
2.
Switch the receiver unit OFF and then ON again in ~1sec intervals FOUR times finally leaving the unit
powered.
3.
After 5 seconds the receiver emits a single ‘buzz’ The unit is now in ‘learn’ Mode
5.
Press the chosen transmitter button.
6.
The receiver will acknowledge by sounding the a single ’buzz’
7.
Press the same transmitter button again, to confirm OK. The receiver will “buz” again to confirm.
8.
Learn Process complete. After 10 seconds the unit will return to ‘normal operation’ mode.
To Pair a Transmitter button to receiver Output Relay #2
1.
Apply power the receiver and wait 10secs for the unit to enter ‘normal operation’ mode.
2.
Switch the receiver unit OFF and then ON again in ~1sec intervals SIX times finally leaving the unit
powered.
3.
After 5 seconds the receiver emits a double ‘buzz’ The unit is now in ‘learn’ Mode
5.
Press the chosen transmitter button.
6.
The receiver will acknowledge by sounding the a double ’buzz’
7.
Press the same transmitter button again, to confirm OK. The receiver will double “buzz” again to
confirm.
8.
Learn Process complete. After 10 seconds the unit will return to ‘normal operation’ mode.
Erasing Receivers Memory
1.
Power the receiver unit up and wait 10 seconds for the unit to enter ‘normal operation’ mode.
2.
Switch the unit off and then on again at ~1 second intervals TEN times, leaving the unit powered.
3.
Wait 5 seconds until a ‘clicking’ sound is heard for a period of 10 seconds.
4.
Wait 10 seconds for the receiver unit to return to ‘normal’ mode
5.
The unit has now erased all encoder data.
NOTE: You cannot erase individual Tx encoders
Configuring Receiver Outputs
The jumper links configure the outputs to be Momentary or Latching.
The jumper links are made/removed by the small link ‘cap’ placed
over the pin header.
Link Positions - Relay Outputs
LK1
Open
Relay #1
Mom
LK2
Open
Relay #2
Mom
Closed
Latch
Closed
Latch
DS VIPER-2
(the above image shows, RLY2 Momentary, RLY1 Latched)
©2009 REG No 277 4001, Lewes, England. Page 5
VIPER Remote Control Systems
Technical Specifications
Transmitters: FIREFLYFIREFLY-TXn
Enclosure Rating:
Standard IPx8
Battery Type:
CR2032 (supplied)
Dimensions:
90 x 54 x 27 mm
Changing the Battery: Remove the six fixing screws, remove battery and replace note polarity
Electrical Characteristics
Min
Supply Voltage
Typical
Max
Units
3V
V
Supply Current
Frequency:
mA
FireFLY: Wideband
RF Output Power (ERP) @ 433 MHz
432.90
433.920
434.10
MHz
-
3
10
mW
Receiver Decoder
Enclosure Rating
Dimensions
Storage Temperature:
IP68
130 x 112 x 42 mm (not including antenna)
-10 to +70o Celsius.
Operating Temperature:
-10 to +50o Celsius.
ELECTRICAL CHARACTERISTICS
MIN
Supply Voltage for +12 v
10.5
Relay Rating* (230Vac) RLY1-4
Supply Current :
TYPICAL
5
Quiescent
MAX
DIMENSION
30
Vdc
12
A
100
mA
mS
300
MS
10
All relays operating*
Time delay from Tx on Switch to Rx Relay operation
Time delay from Tx sw relax to Rx Relay release
140
*The relay contacts in this unit are for functional use only and must not be used for isolation purposes
R F Solutions Ltd.,
Unit 21, Cliffe Industrial Estate,
Lewes, E. Sussex. BN8 6JL. England.
Email : [email protected]
Tel: +44 (0)1273 898 000
DS VIPER-2
http://www.rfsolutions.co.uk
Fax: +44 (0)1273 480 661
©2009 REG No 277 4001, Lewes, England. Page 6