CPI Beverly Microwave Division Solid State Limiters are available from UHF to Ka-Band Typical Operating Parameters Frequency UHF L-Band S-Band C-Band X-Band Ku-Band Ka-band Peak Power Handling 5 KW 3 KW 1 KW 200 W 100 W 50 W 10 W Average Power Handling 300 W 300 W 100 W 20 W 10 W 5W 1W Pulse Width 100 µs 100 µs 100 µs 50 µs 50 µs 50 µs 20 µs Insertion Loss 0.4 dB 0.4 dB 0.5 dB .8 dB 1.3 dB 1.5 dB 2.0 dB Flat Leakage 35 mW 35 mW 35 mW 30 mW 30 mW 30 mW 30 mW Spike Leakage 150 mW 150 mW 150 mW 100 mW 100 mW 100 mW 100 mW Recovery Time 5 µs 5 µs 5 µs 5 µs 1 µs 1 µs 1 µs Features • Low Loss • Low Cost • Small Size The values listed above represent typical limits for the product and design trade-offs are available for enhanced performance of various parameters. The data should be used for basic information only. Formal, controlled specifications may be obtained from CPI for use in equipment design. For information on this and other CPI products visit our webpage at www.cpii.com, or contact CPI Beverly Microwave Division, 150 Sohier Road, Beverly, MA 01915 Telephone: 1 (978) 922-6000 FAX: 1 (978) 922-2736 email: [email protected] CPI │ Solid State Limiters Solid State Coaxial Limiters