CPI Beverly Microwave Division provides the capability to combine the LNA into a single package with the Receiver Protectors Typical Operating Parameters Frequency L-Band S-Band C-Band X-Band Ku-Band Ka-band Peak Power Handling 100 KW 100 KW 100 KW 50 KW 20 KW 10 KW Average Power Handling 500 W 500 W 100 W 50 W 20 W 10 W Pulse Width 100 µs 100 µs 100 µs 100 µs 50 µs 5 µs Noise Figure 3.0 dB 3.0 dB 4.0 dB 4.0 dB 5.0 dB 6.0 dB Gain 30 dB 30 dB 30 dB 20 dB 20 dB 20 dB Max Output Power +20 dBm +20 dBm +20 dBm +20 dBm +16 dBm +15 dBm Recovery Time 2 µs 2 µs 2 µs 2 µs 1 µs 1 µs 1 dB Compression +12 dBm +12 dBm +12 dBm +10 dBm +10 dBm +10 dBm Performance Advantages • Low Noise Figure • High Power Handling • Elimination of transitions and device interconnects • Receiver Protector leakage levels are designed and adjusted to optimally perform with CPI LNA designs The values listed above represent typical limits for the product and design trade-offs are available for enhanced performance of various parameters. The data should be used for basic information only. Formal, controlled specifications may be obtained from CPI for use in equipment design. For information on this and other CPI products visit our webpage at www.cpii.com, or contact CPI Beverly Microwave Division, 150 Sohier Road, Beverly, MA 01915 Telephone: 1 (978) 922-6000 FAX: 1 (978) 922-2736 email: [email protected] CPI │ Receiver Front Ends Receiver Protector with LNA