GATE DRIVE & BASE DRIVE TRANSFORMERS

GATE DRIVE
& BASE DRIVE
TRANSFORMERS
* Designs for Single or Double Eneded Controllers
* High Isolation Voltages
* Designs From 20KHz to >300KHz
* Very Low Leakage Inductance
* Industry Standard Packages
* Multiple Configurations
ELECTRICAL SPECIFICATIONS AT 25OC - OPERATING TEMPERATURE RANGE -25OC TO +80OC
CLICK ON THE RESPECTIVE PART NUMBER TO DISPLAY A DETAIL DATA SHEET
PART
NUMBER
PMGD-02
PMGD-03
PMGD-04
PMGD-05
PMGD-06
PMGD-07
PMGD-08
PMGD-09
PMGD-10
TURNS
RATIO
(Pri:Sec ± 5%)
PRIMARY
OCL
µH Typ.)
(µ
1:1:1
1:1
1:1:1
1 : 0.67
1:1
1:2:2
1 : 1.25 : 1.25
1:2:2
1:2:2
LEAKAGE
IND
µH Max.)
(µ
530
800
24500
6200
6200
2350
575
2350
8350
1.5
2.0
20.0
15.0
15.0
2.0
1.0
2.0
25.0
PRI/SEC
HI-POT
V
1500dc
1500dc
1000dc
1000dc
2000ac
1500ac
3000ac
3000ac
2500ac
PACKAGE
EP13
EP7
EP10
EP10
EP10
EP13
EP13
EP13
EP13
TYPICAL APPLICATION NOTE
150KHz Double Ended Drive
100KHz Single Ended Drive
20KHz Double Ended Drive
25KHz Single Ended Drive
100KHz Double Ended Drive
40KHz Dual Single Ended Drive
180KHz Dual Single Ended Drive
40KHz Dual Single Ended Drive
20KHz Dual Single Ended Drive
TYPICAL APPLICATIONS
TYPICAL SINGLE ENDED APPLICATION CIRCUIT
G
C
S
C25
T1
PMGD-05
B
R30
D5
1
8
E
C
D7
B
VO2
11
R14
DOUBLE ENDED
PWM OUTPUT
PRIMARY
R15
C20
E
3
1.5:1
C
B
1
Q3
Q1
D
E
C
G
B
S
D6
PMGD-XX
OUT B
Q1
E
>>
D10
OUT A
Q1
4
5
PWM DRIVER
(ML4824)
Q1
SEC #1
R17
+Vdc
D
SEC #2
Q2
PRIMARY
+382VDC HOT RAIL >>
TYPICAL DOUBLE ENDED APPLICATION CIRCUIT
Specifications subject to change without notice.
pmgd 04/03
20381 BARENTS SEA CIRCLE, LAKE FOREST, CA 92630 • TEL: (949) 452-0511 • FAX: (949) 452-0512 • http://www.premiermag.com
1
GATE DRIVE
& BASE DRIVE
TRANSFORMERS
* Designs for Gate/Base/Flyback/Push-pull
* High Isolation Voltages
* Designs From 50KHz and up operation frquency
* SMD Industry Standard Packages
*Operation Temp -40C to +85C
* Multiple Configurations
ELECTRICAL SPECIFICATIONS AT 25OC - OPERATING TEMPERATURE RANGE -40OC TO +85OC
TURNS
RATIO
(Pri:Sec ± 5%)
PART
NUMBER
PMGD-50
PMGD-51
PMGD-52
PMGD-53
PMGD-54
PMGD-55
PMGD-56
PMGD-57
PMGD-58
PMGD-59
PMGD-60
PMGD-61
PMGD-62
PMGD-63
PMGD-64
1CT : 1CT
1CT : 2CT
1CT : 2.5CT
1CT : 3CT
1 : 1CT
1 : 2CT
1 : 12.04
1 : 3.0
1:1:1
1:1
1CT : 5CT
1CT : 3CT
1:5
1:1
1 : 1.0
PRIMARY
OCL
µH)
(µ
800 MIN
390 MIN
390 MIN
2000 MIN
2000 MIN
17.2 ± 20%
3.7 ± 20%
9.88 ± 20%
330 MIN
330 MIN
160 MIN N/A
180 MIN N/A
180 MIN N/A
700 ± 20%
785 MIN
LEAKAGE
IND
µH tpy.)
(µ
PRI
DCR
Ω MAX.)
(Ω
SEC
DCR
Ω MAX.)
(Ω
PRI/SEC
HI-POT
VDC
3.00
1.50
1.50
1.20
1.20
1.00
0.275
0.500
0.500
1.0
1.1
1.1
1.1
3.0
0.500
3.50
2.25
2.25
3.00
2.75
1.25
0.90
1.00
2.0
1.0
9.6
8.0
8.3
2.0
1.00
3.50
4.50
6.00
25.0
2.75
3.00
12.25
3.25
2.0
1.0
1250
1250
1250
1250
1250
1250
550
1250
1500
1500
1800
1800
1800
1250
0.6
2.0
0.6
PACKAGE/
SCHEMATIC
EP5G/1
EP5G/1
EP5G/1
EP5G/1
EP5G/2
EP5G/2
EP5G/3
EP5G/4
EP5G/7
EP5G/8
A/5
A/5
A/6
EP5G/3
EP5G/4
SCHEMATICS
4
3
3
1
1
4
1
PRIMARY
SECONDARY
PRIMARY
2
#5
4
5
3
#3
5
3
6
4
6
1
PRIMARY
3
#6
2
1
8
7
6
#8
6
SECONDARY
4
7
SECONDARY
PRIMARY
3
4
2
3
2
PRIMARY
PRIMARY
SECONDARY
#2
6
#7
6
SECONDARY
2
#4
PRIMARY
5
1
SECONDARY
1
SECONDARY
PRIMARY
#1
6
4
3
SECONDARY
6
Specifications subject to change without notice.
pmgd 04/03
20381 BARENTS SEA CIRCLE, LAKE FOREST, CA 92630 • TEL: (949) 452-0511 • FAX: (949) 452-0512 • http://www.premiermag.com
2
GATE DRIVE
& BASE DRIVE
TRANSFORMERS
EP5G MECHANICAL
6
5
EP7 MECHANICALS
4
4
5
6
3
2
1
P PMGD-XX
M YYWW
PIN
#1
(Dot)
1
2
PIN #1
WHITE DOT
.394
(10.01)
MAX
3
.240
(6.10)
MAX
.335
(8.51)
MAX
CORES
TAPED
P PMGD-XX
M XXXX
.250
(6.35)
MAX
.010
(0.25)
.024
(0.6)
.118
(3.00)
TYP
.024
SQ.
.098
(2.49)
.334 (8.5)
MAX
.059
(1.5)
.400
(10.16)
MAX
3
2
.197
(5.00)
1
.22
(5.6)
.197
(5.00)
4
.073
(1.85)
.043
(1.1)
5
6
EP10 MECHANICAL
5
6
7
8
4
3
2
1
EP13 MECHANICAL
PIN #1
WHITE DOT
PIN #1
WHITE DOT
.480
(12.19)
MAX
P PMGD-XX
M XXXX
.475
(12.07)
MAX
3
2
1
5
6
7
8
CORE
TAPED
.550
(13.97)
MAX
.530
(13.46)
MAX
.130
(3.3)
MIN
.024
(.61)
.295
(7.49)
.098
(2.49)
4
P PMGD-XX
M YYWW
CORE
TAPE
.120
(3.81)
MIN
.024
(.61)
.536
(13.61)
MAX
.440
(11.18)
MAX
.024
(.61)
Specifications subject to change without notice.
.024
(.61)
.394
(10.00)
.100
(2.54)
5
4
3
2
1
6
7
8
9
10
pmgd 04/03
20381 BARENTS SEA CIRCLE, LAKE FOREST, CA 92630 • TEL: (949) 452-0511 • FAX: (949) 452-0512 • http://www.premiermag.com
3
GATE DRIVE
& BASE DRIVE
TRANSFORMERS
A MECHANICAL
8
7
6
.50
(12.7)
5
.075
(1.90)
.100
(2.54)
1
2
3
.45
(11.43)
MAX
0.50
(1.27)
8-PL
4
.23
(5.84)
MAX
.100
(2.54)
.03
(.76)
.500
(12.7)
Specifications subject to change without notice.
pmgd 04/03
20381 BARENTS SEA CIRCLE, LAKE FOREST, CA 92630 • TEL: (949) 452-0511 • FAX: (949) 452-0512 • http://www.premiermag.com
4
GATE DRIVE
& BASE DRIVE
TRANSFORMERS
PREMIER
MIDCOM
PMGD-50
PMGD-51
PMGD-52
PMGD-53
PMGD-54
PMGD-55
PMGD-56
PMGD-57
PMGD-60
PMGD-62
31094R
31095R
31096R
30902R
31204R
31098R
31032R
31099R
S5499D COILCRAFT
S6650D COILCRAFT
Specifications subject to change without notice.
pmgd 04/03
20381 BARENTS SEA CIRCLE, LAKE FOREST, CA 92630 • TEL: (949) 452-0511 • FAX: (949) 452-0512 • http://www.premiermag.com
5