TRANSFORMER CONTROL DRAWING PREMIER P/N: PNK

TABLE 1: ELECTRICAL SPECIFICATIONS AT 25OC
FIGURE 1: SCHEMATIC DIAGRAM
1
SPEC LIMITS
MIN.
TYP.
M AX.
UNITS
PRIMARY INDUCTANCE (4-1)
FREQ. = 100 KHZ @ 0.4Vrms
1650
1800
1950
HY
LEAKAGE IND (4-1). (TIE 8-7)
FREQ. = 100 KHZ @ 0.250Vrms
--------
--------
94
HY
PARAMETER
SHIELD #2
NC
1
PRIMARY
TURN RATIO'S:
4 - 1 : 8-7
-------- 14.45:1
--------
+ 3%
PRIMARY RESONANT FREQUENCY
540
--------
--------
kHz
HIPOT:
PRIMARY TO SECONDARY
3000
--------
--------
Vrms
4
8
SECONDARY
7
NC
SHIELD #1
1
FIGURE 2: PHYSICAL DIMENSIONS mm (INCHES)
8
WHITE DOT
DENOES PIN#1
1
7
2
6
3
5
4
15.00
(.59)
MAX
18.54
(.730)
MAX
P PNK-36002
M YYWW
CORE
TAPED
14.6
(.575)
MAX
4.0
(.157)
3.81
(.150)
1
2
3
 0.6
(.023)
NOTE1:
4
A) ALL MATERIALS MEET "UL", "CSA" & "IEC" REQUIREMENTS
B)TRIPLE BASIC INSULATED SECONDARY
C) VARNISH FINISHED ASSEMBLY.
12.5
(.492)
8
7
6
REV.
DESCRIPTION OF CHANGES
BY
02/10/09
OGIRINAL RELEASE
PP
5
UNLESS OTHERW ISE SPECIFIED
DIMENSIONS ARE IN MM
DIMENSIONAL TOLERANCES ARE:
DECIMALS
ANGLES
.X
+ .25
+0 O 30'
.XX + .15
DO NOT SCALE DRAW ING
TRANSFORMER CONTROL DRAWING
PREMIER P/N: PNK-36002
REVISION: 02/10/09
ENGR: PETER PHAM
REF: LNK-XT
SCALE: NONE
SHEET: 1 OF 1