TRANSFORMER CONTROL DRAWING PREMIER P/N: PNK

TABLE 1: ELECTRICAL SPECIFICATIONS AT 25OC
PARAMETER
MIN.
PRIMARY INDUCTANCE (1-2)
FREQ. = 100 KHZ @ 0.40Vrms
1.51
FIGURE 1: SCHEMATIC DIAGRAM
SPEC LIMITS
TYP.
M AX.
1.67
1.83
1
UNITS
PRIMARY
mHY
2
TURN RATIO'S:
2-1 : 5-3
2-1 : 9-6
-------- 1 : .165
-------- 1 : .061
---------------
+ 3%
+ 3%
PRI LEAKAGE IND. (2-1)
FREQ. = 100 KHZ @ 0.250Vrms
TIE 6-7
--------
100
HY
RESONANT FREQUENCY (1-2)
300
--------
3
BIAS
5
--------
--------
9 ([email protected])
SECONDARY
6
2

SHIELD
HIPOT:
PRIMARY TO SECONDARIES
3000
--------
--------
Vrms
NC
FIGURE 2: PHYSICAL DIMENSIONS mm (INCHES)
WHITE DOT
DENOES PIN#1
10
9
1
2
8
7
3
4
6
5
17.0
(.670)
MAX
CORE
TAPED
19.0
(.748)
MAX
15.0
MAX
PNK-62001
Y YWW
P
M
4.0
typ
1
2
3
3.2
4
9
8
7
0.80
5
15.5
10
NOTE1:
A) ALL MATERIALS MEET "UL", "CSA" & "IEC" REQUIREMENTS
B) ALL MATERIAL RATED 130C OR BETTER.
C) VARNISH FINISHED ASSEMBLY.
6
20.0
MAX
REV.
DESCRIPTION OF CHANGES
BY
12/09/09
OGIRINAL RELEASE
PP
RoHS
UNLESS OTHERW ISE SPECIFIED
DIMENSIONS ARE IN MM
DIMENSIONAL TOLERANCES ARE:
DECIMALS
ANGLES
.X
+ .25
+0 O 30'
.XX + .15
DO NOT SCALE DRAW ING
TRANSFORMER CONTROL DRAWING
PREMIER P/N: PNK-62001
REVISION: 12/09/09
ENGR: PETER PHAM
REF: LINK CV
SCALE: NONE
SHEET: 1 OF 1