TRANSFORMER CONTROL DRAWING PREMIER P/N: PNK

TABLE 1: ELECTRICAL SPECIFICATIONS AT 25OC
FIGURE 1: SCHEMATIC DIAGRAM
MIN.
PRIMARY INDUCTANCE (1-3)
FREQ. = 100 KHZ @ 0.4Vrms
2300
2484
2680
HY
LEAKAGE IND (4-1). (TIE5-6)
FREQ. = 100 KHZ @ 0.250Vrms
--------
--------
70
HY
1
UNITS
PRIMARY
SPEC LIMITS
TYP.
M AX.
PARAMETER
5 (12V@260mA)
4
SECONDARY
TURN RATIO'S:
1-3 : 6-5
-------- 3.73 :1
--------
+ 3%
PRIMARY RESONANT FREQUENCY
500
--------
--------
kHz
HIPOT:
PRIMARY TO SECONDARY
3000
--------
--------
Vrms
6
3
SHIELD
NC
FIGURE 2: PHYSICAL DIMENSIONS mm (INCHES)
8
WHITE DOT
DENOES PIN#1
1
7
2
6
3
5
4
15.00
(.59)
MAX
18.54
(.730)
MAX
P PNK-56002
M YYWW
14.6
(.575)
MAX
4.0
(.157)
3.81
(.150)
1
2
3
 0.6
(.023)
NOTE1:
4
A) ALL MATERIALS MEET "UL", "CSA" & "IEC" REQUIREMENTS
B)TRIPLE BASIC INSULATED SECONDARY
C) VARNISH FINISHED ASSEMBLY.
12.5
(.492)
8
7
6
5
UNLESS OTHERW ISE SPECIFIED
DIMENSIONS ARE IN MM
DIMENSIONAL TOLERANCES ARE:
DECIMALS
ANGLES
.X
+ .25
+0 O 30'
.XX + .15
DO NOT SCALE DRAW ING
REV.
DESCRIPTION OF CHANGES
BY
02/10/09
05/11/09
OGIRINAL RELEASE
UPDATE, CEMENT, NO OTHER
PP
PP
TRANSFORMER CONTROL DRAWING
PREMIER P/N: PNK-56002
REVISION: 05/11/09
ENGR: PETER PHAM
REF: LNK-LP
SCALE: NONE
SHEET: 1 OF 2