RELIABILITY TEST REPORT TEST REPORT

No.:T1091
Revision:A
RELIABILITY TEST REPORT
TEST REPORT
Company
:RAIO TECHNOLOGY INC.
Model Name
:RA0086L3N
Date Received
:2009.07.24
Date Tested
:2009.07.28
TESTING LABORATORY IS ACCREDITED BY:
IEC/IECQ 17025 certificate of independent test laboratory approval
Certificate No.:T1091
ISO 9001 certificate is approved by TUV CERT certification body of TUV NORD Cert GmbH
WE HEREBY CERTIFY THAT:
The test(s) shown in the attachment were conducted according to the indicating
procedures. We assume full responsibility for the accuracy and completeness of these
tests and vouch for the qualifications of all personnel performing them.
Name
Signature
Date
Test Engineer
Jay Fang
2009/07/24
Section Manager
Even Lin
2009/07/28
Note:
1. This report will be invalid if reproduced in whole or in part.
2. This report refers only to the specimen(s) submitted to test, and is invalid if used separately.
3. This report is ONLY valid with the examination seal and signature of this institute.
4. The tested specimen(s) will only be preserved for thirty days from the date issued, if not
collected by the applicant.
Integrated Service Technology Inc.
Reliability Engineering Division
No.:T1091
Revision:A
1F, No.19, Pu-ding Rd., Hsin - chu City, Taiwan, R.O.C.
Tel: 886-3-578-2266, Fax: 886-3-5634868
Report No.:HS0907240038A
http://www.istgroup.com
Report No.:RAC9802419-E
Page
RELIABILITY TEST REPORT
Applicant/Department: RAIO TECHNOLOGY INC.
Product
: RA0086L3N
Testing Item
: LATCH-UP
Test Condition
: JEDEC STANDARD NO.78 MARCH 1997
Package/Pin Count : LQFP-100
< 25mA 10mA + I normal
Failure Criteria
> 25mA 1.4 x I normal
Trigger Current
: 50mA ~300mA (±), Step: 50mA (±)
Vsupply OVER VOLTAGE TEST : 5V~8V(+) , Step: 0.5V(+)
1
of
5
Integrated Service Technology Inc.
Reliability Engineering Division
No.:T1091
Revision:A
1F, No.19, Pu-ding Rd., Hsin - chu City, Taiwan, R.O.C.
Tel: 886-3-578-2266, Fax: 886-3-5634868
Report No.:HS0907240038A
http://www.istgroup.com
Report No.:RAC9802419-E
Page
2
LATCH-UP Testing Report
Test Equipment:
KEYTEK ZAPMASTER
#2-6447
Environmental Condition of Laboratory:
Temperature: 25ºC±5ºC
Humidity: 55%±10% RH
Test Condition:
POSITIVE I
NEGATIVE I
Vsupply OVER VOLTAGE TEST
Test Result:
TRIGGER
MODEL
TEST
PIN
SAMPLE
SIZE
I/O
+IT
-IT
I/P
PASS
3
PASS
O/P
PASS
I/O
PASS
I/P
3
O/P
Vsupply
OVER
VOLTAGE
TEST
TRIGGER SOURCE
INDUCE LATCH-UP
VCC
ALL:1-54,56-58,60-62,64,66-100
I/O:54,66-69,73
I/P:56-58,60-62,64,70-72
PASS
PASS
3
PASS
O/P:1-53,74-100
VCC:59,63
VSS:55,65
IT CLASS:
3
NOTE:
CLASS1:
+IT:0mA~39mA
-IT:0mA~ -39mA
CLASS2:
+IT: 40mA~+99mA
-IT: -40mA~-99mA
CLASS3:
+IT:≧100mA
-IT:≦-100mA
of
5
Integrated Service Technology Inc.
Reliability Engineering Division
No.:T1091
Revision:A
1F, No.19, Pu-ding Rd., Hsin - chu City, Taiwan, R.O.C.
Tel: 886-3-578-2266, Fax: 886-3-5634868
Report No.:HS0907240038A
http://www.istgroup.com
Report No.:RAC9802419-E
Page
POSITIVE I
Test TRIGGER
Pin CURRENT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
#1
#2
#3
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Test TRIGGER
Pin CURRENT
49
50
51
52
53
54
56
57
58
60
61
62
64
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
3
of
5
(UNIT::mA)
#1
#2
#3
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Integrated Service Technology Inc.
Reliability Engineering Division
No.:T1091
Revision:A
1F, No.19, Pu-ding Rd., Hsin - chu City, Taiwan, R.O.C.
Tel: 886-3-578-2266, Fax: 886-3-5634868
Report No.:HS0907240038A
http://www.istgroup.com
Report No.:RAC9802419-E
Page
NEGATIVE I
Test TRIGGER
Pin CURRENT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
#1
#2
#3
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Test TRIGGER
Pin CURRENT
49
50
51
52
53
54
56
57
58
60
61
62
64
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
4
of
5
(UNIT::mA)
#1
#2
#3
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Integrated Service Technology Inc.
Reliability Engineering Division
No.:T1091
Revision:A
1F, No.19, Pu-ding Rd., Hsin - chu City, Taiwan, R.O.C.
Tel: 886-3-578-2266, Fax: 886-3-5634868
Report No.:HS0907240038A
http://www.istgroup.com
Report No.:RAC9802419-E
Page
Vsupply OVERVOLTAGE TEST
Test
pin
TRIGGER
VOLTAGE
59
63
5
(UNIT: V)
#1
#2
#3
PASS
PASS
PASS
PASS
PASS
PASS
of
5