Reliability Testing Report

Reliability Testing Report
No.:T1091
PR No: E95060555
Reliability Testing Report
Of
Operating Life Test
Testing Engineer
Report Review
Laboratory Head
Issue Date: 2006/09/10
Integrated Service Technology Inc.
1F, No.22, Pu-Ding., Hsin-Chu, Taiwan, R.O.C.
TEL: (03) 5782266 FAX: (03) 5634868
TQP-23-02
Rev:04
Reliability Testing Report
No.:T1091
PR No: E95060555
CONTENTS
1. CUSTOMER BACKGROUND INFORMATION
2
2. TEST HISTORY
2
3. CONDITION , EQUIPMENTS AND DEVICE
3
4. TESTING RESULTS
4
5. MTTF
5~6
CALCUATE
6. CUSTOMER’S ENCLOSURE
7~11
Integrated Service Technology Inc.
1F, No.22, Pu-Ding., Hsin-Chu, Taiwan, R.O.C.
TEL: (03) 5782266 FAX: (03) 5634868
Page 1 of 11
Reliability Testing Report
No.:T1091
PR No: E95060555
1. CUSTOMER BACKGROUND INFORMATION
Company
: RAIO Technology Inc.
Address
: 6F, No.21, Industry East 4 th Road, Hsinchu Science Park, Hsinchu, Taiwan
Applicant
:
2. TEST HISTORY
Date Finished
Register Date
: 08/12/2006
Test Item
: Operating Life Test
Test Method
Test Sample
: 09/05/2006
: Refer to JESD22-A108-B Test Method
(Customer’s Condition:85
90%RH
500hrs PS1:3.3V,VIH:3.3V)
: RA8803(QFP100)
Testing
Item
Operating Life Test……………………………. ………………………………
Page 11
Remark
The results only apply to the device under test.
This report is 11 pages, and no part of it may be abstracted or reproduced.
Integrated Service Technology Inc.
1F, No.22, Pu-Ding., Hsin-Chu, Taiwan, R.O.C.
TEL: (03) 5782266 FAX: (03) 5634868
Page 2 of 11
Reliability Testing Report
No.:T1091
PR No: E95060555
3. CONDITION, EQUIPMENTS AND DEVICE
3.1 Test Equipment
Burn In System
Calibrate trace code
THS-D5C-100
06-06-BCC-304-01
3.2 Environmental Condition of Laboratory
Temperature
23
5
Humidity
55%± 10% RH
3.3 Specimen
Model
Quantity
3.4 Test Condition
Temperature
Humidity
Voltage
Test Time
RA8803(QFP100)
42ea
85
90%RH
PS1:3.3V, VIH:3.3V
500hours
Integrated Service Technology Inc.
1F, No.22, Pu-Ding., Hsin-Chu, Taiwan, R.O.C.
TEL: (03) 5782266 FAX: (03) 5634868
Page 3 of 11
Reliability Testing Report
No.:T1091
PR No: E95060555
4. TESTING RESULTS
4. 1 Observe surface of samples, no abnormal phenomena was found.
4. 2 Functional testing will be performed by customer and all pass.
Integrated Service Technology Inc.
1F, No.22, Pu-Ding., Hsin-Chu, Taiwan, R.O.C.
TEL: (03) 5782266 FAX: (03) 5634868
Page 4 of 11
Reliability Testing Report
No.:T1091
PR No: E95060555
5. MTTF
CALCUATE
MTTF Formula
Product name: RA8803
Sample sizes : 42EA Fail :0ea
Tj at stress condition:85
Tj at use conditions:55
The failure rate in FITS :
λ=
X 2 1−
α
Test Time:500hrs
2 R + 2 109
100
2 × AF × DH × SS
AF= AFT*AFV
Thermal Acceleration Factor :
1
eV 1
−
k Tr Ttest
AFT = e
k: 8.617 * 10−5 eV / K
Voltage Acceleration Factor :
AFV = e β [E S − E N ]
β : Voltage Acceleration Constant
E S : Stress Voltage
EN
: Nominal Voltage
AFT( 55°C −85°C ) = e
eV 1
1
−
k Tr Ttest
=e
0.7
1
1
−
8.617*10 −5 328 358
=8
AFV = e β [VS −VN ] = e β [5.5−5] = 1
AF = AFT * AFV = 8
Integrated Service Technology Inc.
1F, No.22, Pu-Ding., Hsin-Chu, Taiwan, R.O.C.
TEL: (03) 5782266 FAX: (03) 5634868
Page 5 of 11
Reliability Testing Report
No.:T1091
PR No: E95060555
λ=
MTTF =
1
λ
1
λ
α
2 R + 2 109
4.605 × 10 9
100
=
= 13761( FITS )
2 × AF × DH × SS
2 × 8 × 42 × 500
× 10 9 = 72671
λ=
MTTF =
X ` 1−
X ` 1−
α
(Device-hour)
2 R + 2 109
100
2 × AF × DH × SS
× 10 9 = 182571
=
1.833 × 109
= 5477( FITS )
2 × 8 × 42 × 500
(Device-hour)
Integrated Service Technology Inc.
1F, No.22, Pu-Ding., Hsin-Chu, Taiwan, R.O.C.
TEL: (03) 5782266 FAX: (03) 5634868
Page 6 of 11
Reliability Testing Report
No.:T1091
PR No: E95060555
Integrated Service Technology Inc.
1F, No.22, Pu-Ding., Hsin-Chu, Taiwan, R.O.C.
TEL: (03) 5782266 FAX: (03) 5634868
Page 7 of 11
Reliability Testing Report
No.:T1091
PR No: E95060555
Integrated Service Technology Inc.
1F, No.22, Pu-Ding., Hsin-Chu, Taiwan, R.O.C.
TEL: (03) 5782266 FAX: (03) 5634868
Page 8 of 11
Reliability Testing Report
No.:T1091
PR No: E95060555
Integrated Service Technology Inc.
1F, No.22, Pu-Ding., Hsin-Chu, Taiwan, R.O.C.
TEL: (03) 5782266 FAX: (03) 5634868
Page 9 of 11
Reliability Testing Report
No.:T1091
PR No: E95060555
Integrated Service Technology Inc.
1F, No.22, Pu-Ding., Hsin-Chu, Taiwan, R.O.C.
TEL: (03) 5782266 FAX: (03) 5634868
Page 10 of 11
Reliability Testing Report
No.:T1091
PR No: E95060555
Integrated Service Technology Inc.
1F, No.22, Pu-Ding., Hsin-Chu, Taiwan, R.O.C.
TEL: (03) 5782266 FAX: (03) 5634868
Page 11 of 11