RAIO TECHNOLOGY INC. 7F, No.19-1, Industry East 4th Road, Hsinchu Science Park, Hsinchu, Taiwan, R.O.C. TEL:886-3-5637888 FAX:886-3-5637666 RA6963 LCD Controller Reliability Test Report Testing House : Golden-Tech Technologies Inc. 1F, 176, Sec 2, Gongdaowu Road, Hsinchu 300, Taiwan Measurement Date : March 29, 2010 Part Manufacturer : RAIO TECHNOLOGY INC. 7F, No.19-1, Industry East 4th Road, Hsinchu Science Park, Hsinchu, Taiwan TEL:886-3-5637888 FAX:886-3-5637666 Report Completion/Modify date : 03/30/2010 99012801 Report No. : Page : Gtti Golden-Tech 1 of 4 矽英科技股份有限公司 Golden-Tech Technologies Inc. 1 F, 1 7 6 , S e c . 2 , G o n g d a o w u R o a d , H s i n c h u 3 0 0 , Ta i w a n TEL: 03-5722466 FAX: 03-5722488 E-Mail: [email protected]; [email protected] http://www.myGtti.com.tw Reliability Test Report Ser. No. : 99012801 Company : RAIO Technology Inc. Address : 7F, No.19-1, Industry East 4th Road, Hsinchu Science Park, Hsinchu, Taiwan Date Received : 02/12/2010 Date Finished : 03/29/2010 Lab. Environment : Temp.:25 ℃ ± 5 ℃;Humidity:40 %RH ~ 70 %RH Lab. Accreditation and Certificate: TAF:Certificate # L1043-090506 (accredited under ISO/IEC 17025:2005) IECQ:Certificate # T1090 (accredited under ISO/IEC 17025:2005) We Hereby Certify That: The test(s) shown in the attachment were conducted according to the indicating procedures. We assume full responsibility for the accuracy and completeness of these tests and vouch for the qualifications of all personnel performing them. Remark: 1. This report will be invalid if reproduced in part or altered in any way. 2. This report refers only to the specimen(s) submitted to test, and is invalid if used otherwise. 3. The tested specimen(s) will only be preserved for thirty days from the date issued, if not collected by the applicant. Note:Refer to CD for PDF report sheets. Signature Date Miffy Su Miffy Su 3/31/10 Anthony Chou/ Alex Lin Lillian Chan Anthony 3/31/10 Lillian 3/31/10 Name Testing Engineer Approval Signatory Laboratory Head Gtti Golden-Tech 矽英科技股份有限公司 Golden-tech Technologies Inc. 1F, 176, Sec. 2, Gongdaowu Road, HsinChu 300, Taiwan Tel: 886-3-5722466 Fax: 886-3-5722488 Http://www.myGtti.com.tw E-mail: [email protected] Report Completion/Modify date : Report No. : Page : 03/30/2010 99012801 2 of 4 INDEX General Information Description ………………………………………………………………………………………….3 Testing Item 1. Temperature Humidity Bias Life Test Gtti Golden-Tech 矽英科技股份有限公司 Golden-tech Technologies Inc. 1F, 176, Sec. 2, Gongdaowu Road, HsinChu 300, Taiwan Tel: 886-3-5722466 Report Completion/Modify date : Fax: 886-3-5722488 03/30/2010 Report No. : Http://www.myGtti.com.tw E-mail: [email protected] Page : 3 99012801 of 4 1. Testing Item: 1.1 Temperature Humidity Bias Life Test 2. TEST Specification and/ or standard: 2.1 Refer to JESD22-A101 3. TEST Sample and Quantity: 3.1 Test Sample: IC 3.2 Spec: LQFP67 3.3 Model: RA6963 3.4 Lot No.: 1X7255 3.5 Quantity: 45ea 4. Testing Equipment: (1) TERCHY MHE-225QL 可程式恆溫恆濕試驗機 (Calibrate trace code: 981214 ) 5. Test Condition and procedure: 5.1 Test Condition: 5.1.1 85℃ 85% ; 1000hrs; PS1: 5.5V 5.2 Test Procedure: 5.2.1 Check out Dut card’s pin mapping and matching with IC samples. 5.2.2 Check out IC sample’s quantities and mark with number. 5.2.3 Put Burn-in board into oven till up to test condition then start test. 5.2.4 Take out the samples and send back to the customer for F/T at 168hrs, 500hrs and 1000hrs. 5.2.5 Finish testing, under the room temperature, taking out IC samples, then package and send back to customer. 6. Result: 6.1 Visual Inspection of the 45ea ICs are pass. 6.2 The electrical functions of the 45ea ICs were all pass by customer’s confirmation. Gtti Golden-Tech 矽英科技股份有限公司 Golden-tech Technologies Inc. 1F, 176, Sec. 2, Gongdaowu Road, HsinChu 300, Taiwan Tel: 886-3-5722466 Report Completion/Modify date : Fax: 886-3-5722488 Http://www.myGtti.com.tw E-mail: [email protected] Page : 7. Pictures of Experiment: 7.1 The socket & IC samples within. 03/30/2010 Report No. : 7.2 Prepare for running 4 99012801 of 4 Attachment 1 168 hr FT Test Report Attachment 2 500 hr FT Test Report Attachment 3 1000 hr FT Test Report