Ordering information AC-DC Power Supplies Power Module type TUNS50 TUN 1 S 2 50 3 F 05 4 *Providing heat sink as option 5 -O 6 1Series name 2Single output 3Output wattage 4Universal Input 5Output voltage 6Optional T : with Mounting hole (f3.4 thru) TU *Avoid short circuit between +BC and -BC. It may cause the failure of inside components. *Keep TRM open, if output voltage adjustment is not necessary. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT TUNS50F05 50.0 5V 10A TUNS50F12 50.4 12V 4.2A TUNS50F24 50.4 24V 2.1A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 200V FREQUENCY[Hz] INPUT OUTPUT ACIN 100V ACIN 200V ACIN 100V POWER FACTOR (Io=100%) ACIN 200V INRUSH CURRENT LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +100C*1 -40 to 0C *1 RIPPLE[mVp-p] 0 to 15% Load*1 0 to +100C*1 RIPPLE NOISE[mVp-p] -40 to 0C *1 0 to 15% Load*1 0 to +65C TEMPERATURE REGULATION[mV] -40 to +100C *2 DRIFT[mV] EFFICIENCY[%] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 TU-2 OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD TUNS50F05 TUNS50F12 TUNS50F24 AC85 - 264 1f (Please refer to the instruction manual, 6.5 Derating) 0.67typ (Io=100%) 0.35typ (Io=100%) 50/60 (47 - 63) 79typ 83typ 84typ 81typ 84typ 86typ 0.95typ 0.90typ Limited by external components (Thermistor) 0.75 max (60Hz, According to IEC60950-1) 5 12 24 10 4.2 2.1 10max 24max 48max 10max 24max 48max 80max 120max 120max 120max 150max 150max 200max 280max 380max 120max 150max 150max 200max 200max 250max 280max 360max 460max 50max 120max 240max 100max 240max 480max 20max 40max 90max Fixed (TRM pin open), adjustable by external resistor or external signal 4.50 - 6.00 10.80 - 13.20 21.60 - 26.40 4.97 - 5.13 11.91 - 12.29 23.62 - 24.38 Works over 105% of rating and recovers automatically 6.30 - 7.00 13.90 - 16.35 27.60 - 32.40 Not provided Not provided AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C) -40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max -40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with IEC61000-3-2 (Class A) *3 58.4X12.7X37.3mm [2.3X0.5X1.47 inches] (WXHXD) / 80g max Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) Refer to instruction manual for measuring method of electric characteristics. Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. Please contact us about another class. TUNS50 External view Base Plate (Aluminum) Lot No. 2-f2.5 48.3 [1.9] ¶ Dimensions in : 7.62 25.4 [0.3] [1.0] [0.19] Name Plate -BC (4.7) +BC 2-M3 Mounting Hole [0.5] 12.7 AC2 7.62 7.62 7.62 7.62 [1.47] [0.5] +VOUT [0.3] [0.3] ±0.2 [1.1] TRM AC1 12.7 2-f2 -VOUT [0.05] 1.27 5-f1 ±0.1 2-f3.5 25.4 [1.0] [0.3] [1.9] 7.62 [0.3] [0.3] [0.2] 1.27 [0.05] 48.3 ±0.5 37.3 max [2.3] (5.0) 27.9 ±0.5 58.4 max 5-f1.5 [0.2] 5.0 ±0.5 Case (PBT) [0.5] 12.7 ±0.5 ¶Recommending size for processing PCB (TOP VIEW) mm [inch] ¶ Div. : 0.2inch ¶ Tolerance : ±0.3 [±0.012] ¶ Weight : 80g max ¶ Dimensions in mm, [ ]=inches ¶ Mounting hole screwing torque : 0.49N-m (5.0kgf-cm) max TU-3 TU Ordering information AC-DC Power Supplies Power Module type TUNS100 TUN 1 S 2 100 3 F 4 *Providing heat sink as option 05 5 -O 6 1Series name 2Single output 3Output wattage 4Universal Input 5Output voltage 6Optional T : with Mounting hole (f3.4 thru) TU *Avoid short circuit between +BC and -BC. It may cause the failure of inside components. *Keep TRM open, if output voltage adjustment is not necessary. *If remote sensing is not necessary, connect between +Vout & +S and between -Vout & -S. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT TUNS100F05 100.0 5V 20A TUNS100F12 100.8 12V 8.4A TUNS100F24 100.8 24V 4.2A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 200V FREQUENCY[Hz] INPUT OUTPUT ACIN 100V ACIN 200V ACIN 100V POWER FACTOR (Io=100%) ACIN 200V INRUSH CURRENT LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +100C*1 -40 to 0C *1 RIPPLE[mVp-p] 0 to 15% Load*1 0 to +100C*1 RIPPLE NOISE[mVp-p] -40 to 0C *1 0 to 15% Load*1 0 to +65C TEMPERATURE REGULATION[mV] -40 to +100C *2 DRIFT[mV] EFFICIENCY[%] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 TU-4 OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD TUNS100F05 TUNS100F12 TUNS100F24 AC85 - 264 1f (Please refer to the instruction manual, 6.5 Derating) 1.3typ (Io=100%) 0.7typ (Io=100%) 50/60 (47 - 63) 82typ 83typ 84typ 85typ 85typ 86typ 0.95typ 0.90typ Limited by external components (Thermistor) 0.75 max (60Hz, According to IEC60950-1) 5 12 24 20 8.4 4.2 10max 24max 48max 10max 24max 48max 80max 120max 120max 120max 150max 150max 160max 240max 240max 120max 150max 150max 200max 200max 250max 240max 300max 300max 50max 120max 240max 100max 240max 480max 20max 40max 90max Fixed (TRM pin open), adjustable by external resistor or external signal 4.50 - 6.00 10.80 - 13.20 21.60 - 26.40 4.97 - 5.13 11.91 - 12.29 23.62 - 24.38 Works over 105% of rating and recovers automatically 6.30 - 7.00 13.90 - 16.35 27.60 - 32.40 Provided Not provided AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C) -40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max -40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with IEC61000-3-2 (Class A) *3 58.4X12.7X61.0mm [2.3X0.5X2.4 inches] (WXHXD) / 120g max Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) Refer to instruction manual for measuring method of electric characteristics. Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. Please contact us about another class. TUNS100 External view Base Plate (Aluminum) 12.7 ±0.5 [0.5] Lot No. Case (PBT) 5.0 ±0.5 [0.2] ¶Recommending size for processing PCB (TOP VIEW) 58.4 max 48.3 ±0.5 [0.2] [1.9] 2-f2.5 TU 2-f2 ±0.2 7-f1 ±0.1 61max [0.4] 7.62 5.08 5.08 7.62 7.62 10.16 [0.3] [0.2][0.2] [0.3] [0.3] [0.4] 50.8 [2.0] +S [2.4] [2.0] 50.8±0.5 TRM [0.3] [0.3] [0.5] -S AC2 [0.4] -VOUT 10.16 7.62 7.62 10.16 7-f1.5 AC1 +VOUT 4-f3.5 7.62 Name Plate [0.3] -BC 25.4 [1.0] [0.2] +BC 48.3 [1.9] ( 5.1) 12.7 25.4 [1.0] 4-M3 Mounting Hole [2.3] (5.0) 7.62 [0.3] ¶ Dimensions in : mm [inch] ¶ Div. : 0.2inch ¶ Tolerance : ±0.3 [±0.012] ¶ Weight : 120g max ¶ Dimensions in mm, [ ]=inches ¶ Mounting hole screwing torque : 0.49N-m (5.0kgf-cm) max TU-5