Ordering information Unit type PBA150F PBA 150 1 2 F 3 -5 4 -O 5 1Series name 2 Output wattage 3 Universal input 4 Output voltage 5 Optional C :with Coating G :Low leakage current (0.15mA max / ACIN 240V) E :Low leakage current and EMI class A (0.5mA max / ACIN 240V) T :Vertical terminal block J :Connector type (Only -12,-15,-24,-36,-48) R :with Remote ON/OFF N :with Cover (Only 24V UL508 is acquired) N1 :with DIN rail V :Output voltage setting potentiometer externally R Specification is changed at option. Please consult us details. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT PBA150F-3R3 PBA150F-5 99 150 3.3V 30A 5V 30A PBA150F-9 150.3 9V 16.7A PBA150F-12 156 12V 13A PBA150F-15 150 15V 10A PBA150F-24 156 24V 6.5A PBA150F-36 154.8 36V 4.3A PBA150F-48 158.4 48V 3.3A PBA150F-3R3 PBA150F-5 PBA150F-9 PBA150F-12 PBA150F-15 AC85 - 264 1f or DC120 - 370 (AC50 or DC70 optionally available *4) PBA150F-24 PBA150F-36 PBA150F-48 85typ 88typ 85typ 88typ 85typ 88typ 24 6.5 96max 150max 120max 160max 150max 180max 36 4.3 144max 240max 150max 200max 250max 300max 48 3.3 192max 240max 150max 200max 250max 300max 150max 180max 60max 240max 290max 96max 360max 450max 144max 480max 600max 192max 13.2 - 18.0 14.5 - 15.5 19.2 - 27.0 23.5 - 24.5 28.8 - 39.6 35.5 - 36.5 39.0 - 53.0 47.0 - 49.0 5.75 - 7.00 11.5 - 14.0 15.0 - 18.0 20.0 - 25.0 30.0 - 37.0 PROTECTION OVERVOLTAGE PROTECTION[V] 4.00 - 5.25 CIRCUIT AND OPERATING INDICATION LED (Green) OTHERS REMOTE SENSING Optional (Only -3R3, -5 Option -K) REMOTE ON/OFF Optional (Required external power source) INPUT-OUTPUT -RC *3 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) ISOLATION OUTPUT-RC-FG *3 AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature) OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max ENVIRONMENT VIBRATION 19.6m/s2 (2G), 10 - 55Hz, 3minutes period, 60minutes each along X, Y and Z axis 43.0 - 50.0 58.0 - 65.0 SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] FREQUENCY[Hz] INPUT OUTPUT EFFICIENCY[%] ACIN 100V 1.3typ 2.0typ ACIN 200V 0.7typ 1.0typ 50/60 (47 - 63) ACIN 100V 80typ 83typ ACIN 200V 82typ 86typ ACIN 100V POWER FACTOR(Io=100%) ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -10 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] -10 - 0C *1 0.98typ 0.99typ 0.87typ 0.93typ 20typ (Io=100%) (At cold start) 40typ (Io=100%) (At cold start) 0.4/0.75max (ACIN 100V/240V 3.3 5 30 30 20max 20max 40max 40max 80max 80max 140max 140max 120max 120max 160max 160max 82typ 85typ 83typ 86typ 60Hz, Io=100%, 9 16.7 36max 100max 120max 160max 150max 180max 0 to +50C 50max 50max 90max -10 to +50C 60max 60max 120max DRIFT[mV] *2 20max 20max 36max START-UP TIME[ms] 350typ(ACIN 100V, Io=100%) HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.63 4.00 - 5.50 7.50 - 10.0 OUTPUT VOLTAGE SETTING[V] 3.20 - 3.40 4.90 - 5.20 8.70 - 9.30 OVERCURRENT PROTECTION Works over 105% of rated current and recovers TEMPERATURE REGULATION[mV] IMPACT AGENCY APPROVALS SAFETY AND CONDUCTED NOISE NOISE REGULATIONS CE MARKING HARMONIC ATTENUATOR OTHERS CASE SIZE/WEIGHT COOLING METHOD 84typ 87typ According to IEC60950-1) 12 15 13 10 48max 60max 100max 120max 120max 120max 160max 160max 150max 150max 180max 180max 120max 150max 48max 10.0 - 13.2 11.5 - 12.5 automatically 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN (At only AC input) Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Low Voltage Directive, EMC Directive Complies with IEC61000-3-2 34X93X168mm (without terminal block) (WXHXD) / 560g max (without cover) Convection *1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3 Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and FG. *4 Derating is required.Consult us for details. * * * Parallel operation with other model is not possible. Derating is required when operated with cover. A sound may occur from power supply at peak loading.