PBA300F - Total Power International

Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com
Ordering information
Unit type
PB
PBA300F
PB
1
A
2
300
3
F
4
Recommended Noise Filter
NAC-06-472
R
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The Noise Filter is recommended
*to connect with several devices.
-5
5
-O
6
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional
*5
C :with Coating
G :Low leakage current
U :Operation stop voltage
is set at a lower value
F3 :Reverse air exhaust
type
F4 :Low speed fan
N1 :with DIN rail
Refer to instruction manual
7.1.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA300F-3R3
198
ACIN 100V 3.3V 60A
ACIN 200V *3 3.3V 60A
PBA300F-5
300
5V 60A
5V 60A
PBA300F-7R5
300
7.5V 40A
7.5V 40A
PBA300F-12
324
12V 27A
12V 27A
PBA300F-15
330
15V 22A
15V 22A
PBA300F-24
336
24V 14A
24V 14(16.5)A
PBA300F-36
324
36V 9A
36V 9A
PBA300F-48
336
48V 7A
48V 7A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 100V
ACIN 200V
FREQUENCY[Hz]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
ACIN 100V
CURRENT[A]
ACIN 200V *3
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50C *1
RIPPLE[mVp-p]
-20 - 0C *1
0 to +50C *1
RIPPLE NOISE[mVp-p]
-20 - 0C *1
0 to +50C *1
TEMPERATURE REGULATION[mV]
-20 to +50C *1
DRIFT[mV]
*2
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION[V]
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT -RC
INPUT-FG
OUTPUT-RC-AUX-FG
OUTPUT-RC -AUX
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS (At only AC input)
CONDUCTED NOISE
CE MARKING
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
PBA300F-3R3 PBA300F-5
PBA300F-7R5 PBA300F-12 PBA300F-15 PBA300F-24 PBA300F-36
AC85 - 264 1f or DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option *4)
3typ
4.1typ
1.6typ
2typ
50/60 (47 - 63)
68typ
74typ
76typ
78typ
78typ
79typ
81typ
71typ
77typ
79typ
81typ
81typ
82typ
84typ
0.98typ (Io=100%)
0.95typ (Io=100%)
20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
0.45/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
3.3
5
7.5
12
15
24
36
60
60
40
27
22
14
9
60
60
40
27
22
14(16.5)
9
20max
20max
36max
48max
60max
96max
144max
40max
40max
60max
100max
120max
150max
150max
80max
80max
120max
120max
120max
120max
150max
140max
140max
160max
160max
160max
160max
160max
120max
120max
150max
150max
150max
150max
200max
160max
160max
180max
180max
180max
180max
240max
40max
50max
75max
120max
150max
240max
360max
60max
75max
120max
180max
180max
290max
440max
12max
20max
30max
48max
60max
96max
144max
300typ(ACIN 100/200V, Io=100%) *Start-up time is 500ms typ for less than 1minute of applying input again from turning off
20typ (ACIN 100/200V, Io=100%)
2.64 - 3.96
3.96 - 6.00
5.25 - 8.25
8.25 - 13.20
10.50 - 16.50 16.50 - 26.40 25.20 - 39.60
3.30 - 3.40
5.00 - 5.15
7.50 - 7.80
12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44
Works over 105% of rated current or 101% of peak current and recovers automatically
4.3 - 6.3
6.5 - 8.0
9.0 - 11.6
14.4 - 18.6
18.0 - 23.3
28.8 - 37.2
43.2 - 54.0
LED (Green)
Provided
Provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
-20 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Low Voltage Directive, EMC Directive
Complies with IEC61000-3-2
102X42X170mm (without terminal block and screw) (WXHXD) /1.0kg max
Forced cooling (internal fan)
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
in detail.
*4 Derating is required.Consult us for details.
A-18
*
A sound may occur from power supply at pulse loading.
*5 Please contact us about safety approvals for the model with option.
PBA300F-48
79typ
82typ
48
7
7
192max
300max
150max
400max
200max
500max
480max
600max
192max
the input voltage.
38.40 - 56.00
48.00 - 49.92
57.6 - 80.0
Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US)PH# (978) 453-7272 www.total-power.com
PBA300F
PB
Block diagram
AC IN
85 - 264V
FUSE
NOISE
FILTER
250V10A
RECTIFIER
INRUSH
CURRENT
LIMIT
FG
RECTIFIER
AND
FILTER
INVERTER
DC OUT
THERMAL
PROTECTION
CURRENT
SENSING
±M
OVER VOLTAGE
PROTECTION
ACTIVE FILTER
RECTIFIER
AND
FILTER
SWITCHING
DEVICE
CONTROL
CONTROL
±S(REMOTE SENSING)
RC(REMOTE ON / OFF)
VOLTAGE
SENSING
MASTER
SLAVE
CONTROL
CURRENT
SENSING
VOLTAGE
SENSING
CONTROL
INTERNAL
REGURATOR
FAN
VB(VOLTAGE BALANCE)
CB(CURRENT BALANCE)
ALARM
PG(POWER GOOD)
AUX(12 V 0.1A)
External view
20 ±0.5 12
4-M4
Mounting Hole
54
Name plate
Terminal cover
2-M4
Mounting Hole
(Bottom sides)
25max
102
50.5
12
Output terminal(+)
H
V.ADJ
M4
(15.5)
(30)
CN3
CN2
Name plate
CN1
LED
Output voltage
adjustable potentiometer
¶ Tolerance : ±1
¶ Mass : 1.0kg or less
¶ PCB Material/thickness : FR-4 / 1.6mm
¶ Chassis material : Aluminum
¶ Dimensions in mm
¶ Mounting torque : 1.2N • m max
¶ Screw tightening torque : 1.6N • m max
¶ The housing for the remote sensing unused is mounted on CN1
¶ Please connect safety ground to FG terminal on the unit.
28.5
64±0.5
170
6max
AIR FLOW
42
12
(23.5)
AC(L)
AC(N)
FG( )
Output terminal(-)
(75)
(87)
10 7
8.6
(50)
M4
(6)
(14)
74±0.5
A-19