Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com Ordering information Unit type PB PBA300F PB 1 A 2 300 3 F 4 Recommended Noise Filter NAC-06-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series *The Noise Filter is recommended *to connect with several devices. -5 5 -O 6 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional *5 C :with Coating G :Low leakage current U :Operation stop voltage is set at a lower value F3 :Reverse air exhaust type F4 :Low speed fan N1 :with DIN rail Refer to instruction manual 7.1. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT PBA300F-3R3 198 ACIN 100V 3.3V 60A ACIN 200V *3 3.3V 60A PBA300F-5 300 5V 60A 5V 60A PBA300F-7R5 300 7.5V 40A 7.5V 40A PBA300F-12 324 12V 27A 12V 27A PBA300F-15 330 15V 22A 15V 22A PBA300F-24 336 24V 14A 24V 14(16.5)A PBA300F-36 324 36V 9A 36V 9A PBA300F-48 336 48V 7A 48V 7A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 200V FREQUENCY[Hz] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS ACIN 100V ACIN 200V ACIN 100V POWER FACTOR ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] ACIN 100V CURRENT[A] ACIN 200V *3 LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -20 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] -20 - 0C *1 0 to +50C *1 TEMPERATURE REGULATION[mV] -20 to +50C *1 DRIFT[mV] *2 START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT -RC INPUT-FG OUTPUT-RC-AUX-FG OUTPUT-RC -AUX OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS (At only AC input) CONDUCTED NOISE CE MARKING HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD EFFICIENCY[%] PBA300F-3R3 PBA300F-5 PBA300F-7R5 PBA300F-12 PBA300F-15 PBA300F-24 PBA300F-36 AC85 - 264 1f or DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option *4) 3typ 4.1typ 1.6typ 2typ 50/60 (47 - 63) 68typ 74typ 76typ 78typ 78typ 79typ 81typ 71typ 77typ 79typ 81typ 81typ 82typ 84typ 0.98typ (Io=100%) 0.95typ (Io=100%) 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start) 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start) 0.45/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN) 3.3 5 7.5 12 15 24 36 60 60 40 27 22 14 9 60 60 40 27 22 14(16.5) 9 20max 20max 36max 48max 60max 96max 144max 40max 40max 60max 100max 120max 150max 150max 80max 80max 120max 120max 120max 120max 150max 140max 140max 160max 160max 160max 160max 160max 120max 120max 150max 150max 150max 150max 200max 160max 160max 180max 180max 180max 180max 240max 40max 50max 75max 120max 150max 240max 360max 60max 75max 120max 180max 180max 290max 440max 12max 20max 30max 48max 60max 96max 144max 300typ(ACIN 100/200V, Io=100%) *Start-up time is 500ms typ for less than 1minute of applying input again from turning off 20typ (ACIN 100/200V, Io=100%) 2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 Works over 105% of rated current or 101% of peak current and recovers automatically 4.3 - 6.3 6.5 - 8.0 9.0 - 11.6 14.4 - 18.6 18.0 - 23.3 28.8 - 37.2 43.2 - 54.0 LED (Green) Provided Provided AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature) -20 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Low Voltage Directive, EMC Directive Complies with IEC61000-3-2 102X42X170mm (without terminal block and screw) (WXHXD) /1.0kg max Forced cooling (internal fan) *1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual in detail. *4 Derating is required.Consult us for details. A-18 * A sound may occur from power supply at pulse loading. *5 Please contact us about safety approvals for the model with option. PBA300F-48 79typ 82typ 48 7 7 192max 300max 150max 400max 200max 500max 480max 600max 192max the input voltage. 38.40 - 56.00 48.00 - 49.92 57.6 - 80.0 Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US)PH# (978) 453-7272 www.total-power.com PBA300F PB Block diagram AC IN 85 - 264V FUSE NOISE FILTER 250V10A RECTIFIER INRUSH CURRENT LIMIT FG RECTIFIER AND FILTER INVERTER DC OUT THERMAL PROTECTION CURRENT SENSING ±M OVER VOLTAGE PROTECTION ACTIVE FILTER RECTIFIER AND FILTER SWITCHING DEVICE CONTROL CONTROL ±S(REMOTE SENSING) RC(REMOTE ON / OFF) VOLTAGE SENSING MASTER SLAVE CONTROL CURRENT SENSING VOLTAGE SENSING CONTROL INTERNAL REGURATOR FAN VB(VOLTAGE BALANCE) CB(CURRENT BALANCE) ALARM PG(POWER GOOD) AUX(12 V 0.1A) External view 20 ±0.5 12 4-M4 Mounting Hole 54 Name plate Terminal cover 2-M4 Mounting Hole (Bottom sides) 25max 102 50.5 12 Output terminal(+) H V.ADJ M4 (15.5) (30) CN3 CN2 Name plate CN1 LED Output voltage adjustable potentiometer ¶ Tolerance : ±1 ¶ Mass : 1.0kg or less ¶ PCB Material/thickness : FR-4 / 1.6mm ¶ Chassis material : Aluminum ¶ Dimensions in mm ¶ Mounting torque : 1.2N • m max ¶ Screw tightening torque : 1.6N • m max ¶ The housing for the remote sensing unused is mounted on CN1 ¶ Please connect safety ground to FG terminal on the unit. 28.5 64±0.5 170 6max AIR FLOW 42 12 (23.5) AC(L) AC(N) FG( ) Output terminal(-) (75) (87) 10 7 8.6 (50) M4 (6) (14) 74±0.5 A-19