to this file: /tps_px500

PX500 Series
AC/DC 500W Multiple Output Power Supply
SELECTION GUIDE
Model Number
FEATURES
n Industry Standard 2"x5"x10" Package
n 500W Power at 0-50ºC
n Active Power Factor Correction
n Efficiency up to 75%
n Power Fail Warning Signal
n 80A Main Output
n Remote Sense on Main Output
n Remote Inhibit Control
n Class B conducted EMI Performance
Output 1
Output 2
Output 3
Output 4
PX500U3ABFHPHM
5V@80A
12V@12A
12V@12A
--
NA
PX500U3BBFHPHM
5V@80A
15V@12A
15V@12A
--
NA
PX500U4CBFHPHM
5V@80A
12V@12A
12V@12A
5V@4A
NA
PX500U4CBFHPHMC
5V@80A
12V@12A
12V@12A
5V@4A
Yes
PX500U4EBFHPHM
5V@80A
12V@12A
12V@12A
12V@4A
NA
PX500U4HBFHPHM
5V@80A
12V@12A
12V@12A
5.2V@10A
NA
PX500U4HBFHPHMC
5V@80A
12V@12A
12V@12A
5.2V@10A
Yes
PX500U4HBVHPHM
5V@80A
12V@12A
12V@12A
5.2V@10A
NA
PX500U4HBVHPHMC
5V@80A
12V@12A
12V@12A
5.2V@10A
Yes
PX500U4LBFHPHM
5V@80A
12V@12A
12V@12A
3.3V@10A
NA
PX500U4LBFHPHMC
5V@80A
12V@12A
12V@12A
3.3V@10A
Yes
T
C
U
D t Model
O
R
P
en
m
E
e
c
T r Repla
E
L
O ctory fo
S
B
O act Fa
INPUT CHARACTERISTICS
Parameter
Conditions
Input Operating Voltage
nt Frequency
CoInput
n Global 90-264VAC Input
Input Current
n Active Current Sharing on Output V1
Power Factor
n RoHS Compliant
Inrush Current
Min
Typ
90
Max
Units
264
Vac
47
63
Hz
7.0
Arms
240Vac
70
Apk
120Vac
30
Apk
0.99
DESCRIPTION
The PX500 is a family of 500W, multiple-output
power supplies developed for a broad range of
applications. All outputs are fully isolated and
regulated for either positive or negative ground
reference. The outputs can also be connected in
series to develop higher voltages or in parallel to
develop higher currents.
The two-switch forward topology used in the
PX500 supplies has been field-proven for high
reliability. The mag-amp post-regulators used
on the auxiliary outputs will support high peak
currents.
With a global input of 90-264VAC, safety agency
approvals to UL1950, CSA C22.2 No. 234-M90,
and EN60950, EMI compliance to Class B FCC
Part 15, the PX500 was designed with globallydeployed product applications in mind.
The PX500 is available in various output voltage/
current configurations and with various cover options. Additional features include remote sense
compensation, a power fail warning signal, as
well as output inhibit. Several models of the
PX500 are also available with RoHS compliance.
ISO9001
CERTIFIED
OUTPUT CHARACTERISTICS
Parameter
Conditions
Output Power
All line & environmental
Temperature Coefficient
After 30min warm up
Typ
Max
Units
500
W
0.02
%/ºC
Line
-0.1
+0.1
%Vo
Voltage Regulation
Load
-0.5
+0.5
%Vo
Cross
-0.1
+0.1
%Vo
Minimum Load
V1
4
Minimum Load
V2, V3, V4
0
PARD (Vo)
20MHz bandwidth
Output Voltage Adjustment
All outputs
Transient Excursion (Vo)
25% load step, 1A/μsec
max slew
Transient Recovery (Vo)
25% load step, 1A/μsec
max slew
Output Holdup Time
Full load, low line
Isolation, Pri-Sec
A
A
1
%Vnom
-5
+5
%Vnom
-3
+3
%Vo
400
μsec
20
msec
3
kVac
Isolation, Pri-Chassis
1.5
kVac
Isolation, Sec-Chassis
500
Vac
Current Share Tolerance
Remote Sense Comp. (Vo)
www.murata-ps.com
Min
Output V1; Io>25%
10
%
1000
mV
Technical enquiries - email: [email protected], tel: +1 508 339 3000
PX500 Series
AC/DC 500W Multiple Output Power Supply
GENERAL CHARACTERISTICS
Parameter
Conditions
Efficiency
Switching Frequency
Min
Typ
Max
Full load, 240Vac
70
75
PFC Converter
100
MTBF
Mil-HDBK-217E
Weight
Unpackaged
Units
%
kHz
113
khrs
4
lbs
PROTECTION
Inception
Parameter
Conditions/Response
Output OverVoltage Protection
V1; Latching; cycle AC input to re-start
Output Overload Protection
All outputs; individual current limit; automatic recovery
Min
Nom
Max
Units
6.0
6.5
7.0
V
120
Output Power Limit
Thermal Shutdown
Input Protection
ENVIRONMENTAL CHARACTERISTICS
Parameter
Ambient Operating Temperature
Ambient Storage Temperature
Operating Humidity
Storage Humidity
Automatic Recovery
T
C
U
D
del
O
o
M
R ement
P
E
T r Replac
E
L
O ctory fo
S
B
O act Fa
Altitude
W
100
ºC
Internal line fuse; Littlefuse 312010 or equivalent
Conditions
De-rate output power linearly above 50ºC to 250W at 70ºC
Non-condensing
t
ConNon-condensing
%Io
550
10
A
Min
Typ
Max
Units
0
+50
+70
ºC
-20
+85
ºC
10
90
%
5
90
%
Operating. De-rate operating ambient temperature by 2Cº per 1000ft above 5000ft.
-200
10000
ft
Storage
-200
50000
ft
ELECTROMAGNETIC COMPATIBILITY (EMC)
Characteristic
Compliance
Input Current Harmonics
EN61000-3-2, Class A
Conducted Emissions
CFR Title 47, Part 15, Sub-part B, Class B (when the cover option is employed)
EN55022, Class A
CERTIFICATIONS
Agency/Characteristic
Standard
UL
UL1950 & UL1012 (File Number E14675)
CSA
CSA 22.2 No. 234-M90, Level 6 (File Number LR 9070-154C)
TUV
EN60950 (License Number R9576030)
CE
LVD Directive; self-certified
RoHS
EN Directive 2002/95/EC; self-certified (see selection guide table on page 1 for compliance)
SELV
Self-certified
Vibration
MIL-STD-810D, Method 514.3, Procedure I; self-certified
Shock
MIL-STD-810D, Method 516.3, Procedure I; self-certified
www.murata-ps.com
Technical enquiries - email: [email protected], tel: +1 508 339 3000
PX500 Series
AC/DC 500W Multiple Output Power Supply
MECHANICAL DIMENSIONS
(Top-Mounted Fan Cover, Option “F”)
T
C
U
D t Model
O
R
P acemen
E
T
E
epl
L
R
r
O ctory fo
S
B
O act Fa
MECHANICAL DIMENSIONS
t
Con
(End-Vented Fan Cover, Option “V”)
www.murata-ps.com
Technical enquiries - email: [email protected], tel: +1 508 339 3000
PX500 Series
AC/DC 500W Multiple Output Power Supply
MODEL NUMBERING
CONNECTIONS
PX
Product Family
INPUT (Terminal Block TB1)
Ref
500
Maximum continuous output power in Watts
TB1-1
Chassis Ground
G
U
U-Channel chassis
TB1-2
Input Neutral
N
x
Number of outputs (3 or 4)
TB1-3
Input Line
L
x
Output voltage & current configuration (see Selection Guide table on page 1 for details)
OUTPUT (Terminal Block TB2)
Ref
B
Conducted emissions compliance level
TB2-1
Output 4 Return
-V4
x
Cover Options (F, V)
TB2-2
Output 4
+V4
H
Remote Inhibit/Enable Logic (Logic 1 enables output)
TB2-3
Output 3 Return
-V3
P
Power Factor Corrected
TB2-4
Output 3
+V3
H
Power Fail Warning Logic (Logic 1 indicates AC applied)
TB2-5
Output 2 Return
-V2
M
Active current sharing on Main output (V1)
TB2-6
Output 2
+V2
SAFETY AGENCY RATINGS
Input Voltage
Input Current
120/240Vac
CONTROL (Molex PN 22-28-1050)
Ref
J1-1
Remote Sense +
S-
J1-2
Remote Sense -
S+
J1-3
V1 Current Share
CS
J1-4
Remote Inhibit
RI
J1-5
AC Power Fail Warning
PFW
T
C
U
D
del
O
o
M
R ement
P
E
T r Replac
E
L
O ctory fo
S
B
O act Fa
8A-4A
t
Con
www.murata-ps.com
Technical enquiries - email: [email protected], tel: +1 508 339 3000