Click Here to download this file: http://www.murata-ps.com/data/acdcsupplies/tps_nx301.pdf

Contact Factory for Replacement Model
300 WATT
AC/DC POWER SUPPLY
.8
DESCRIPTION
4HE.8ISACOMPACTWATT0OWER&ACTOR#ORRECTED
MULTIPLEOUTPUTPOWERSUPPLY!LLOUTPUTSAREFULLYISOLATED
ANDREGULATED!CTIVECURRENTSHARINGCIRCUITRYTOGETHERWITH
CONTROLFUNCTIONSANDALARMOPTIONSSIMPLIFIES.AND
REDUNDANTAPPLICATIONS&ANANDDISKDRIVEAPPLICATIONSARE
HANDLEDBYTHEPEAKCURRENTRATINGSOFTHEAUXILIARYOUTPUTS
FEATURES
Active Power Factor Correction
Fully Isolated Outputs
Low Profile: 9” x 4.85” x 2.00”
One, Two, Three and Four Output Models
N+1 Current Sharing
FCC/VDE Class B EMI Filter Standard
Optional Fan Mounted On Cover
AGENCY APPROVALS
www.murata-ps.com
Technical enquiries - email: [email protected], tel: +1 508 339 3000
Input Specifications
Parameter
Operating Range
Conditions
Max
Units
264
VAC
120VAC, cold start
35
APK
240VAC, cold start
70
APK
47-63 Hz
Min
Typ
90
Inrush Current Limiting
Efficiency
120V
120V, full load
70
%
240V
240V, full load
75
%
Power Factor Correction (PFC)
0.99
Meets IEC 1000-4-7/EN61000-3-2 (formerly IEC 555-2)
Remote Sense
Remote Sense is provided on Output #1 and will
compensate for 0.7V of line drop. Remote Sense leads
are protected against open, short and reversal.
Remote On/Off
The power supply is turned on with a TTL logic ‘1’ (or open)
signal and turned off by a switch closure or TTL logic ‘0’
referenced to (-) sense terminal. Consult the factory for
other options.
Over Voltage Protection
Output #1: 6.5V ± 0.5 VDC.
The power supply will latch off until AC power is cycled.
Over Current Protection
Individual current limit on all outputs. Automatic recovery
upon fault removal.
Transient Response
The peak output voltage excursion will not exceed 2% and
will recover within 1% in 200 μsec for a 25% load step
change.
Power Fail Signal
Upon AC input voltage removal, the power fail signal drops
to logic zero at least 5msec before loss of DC output. On
AC input turn-on, signal remains low until outputs are in
regulation. Consult the factory for other options.
N + 1 Load Share
Output #1 has active load sharing circuitry. Units will load
share within 1.5% of Maximum Rated Load.
Over Temperature Protection
Thermal switch turns off power supply if overheating occurs
and automatically restarts.
Safety
UL Recognized: UL File Number E14675 (1950 & 1012)
CSA Certified: CSA File Number LR 9070-154C
(C22.2 No. 234-M90, Level 6)
TUV License Number: R9576031 (EN60950) (IEC950)
Cooling
The unit is designed to operate with 30 CFM of airflow.
Output Isolation
All outputs are fully isolated.
www.murata-ps.com
Technical enquiries - email: [email protected], tel: +1 508 339 3000
Output Voltages and Maximum Rated Loads
MODEL NUMBER
OUTPUT #1
VOUT
IMAX
OUTPUT #2
VNOM IMAX/IPK
OUTPUT #3
VNOM IMAX/IPK
OUTPUT #4
VNOM
IMAX
NX301-U3A
±5V
45A
± 12V
8A/10A
± 12V
8A/10A
-
-
NX301-U3B
±5V
45A
± 15V
8A/10A
± 15V
8A/10A
-
-
NX301-U4C
±5V
45A
± 12V
8A/10A
± 12V
8A/10A
± 5V
3.0A
NX301-U4D
±5V
45A
± 12V
8A/10A
± 12V
8A/10A
± 24V
1.5A
NX301-U4E
±5V
45A
± 12V
8A/10A
± 12V
8A/10A
± 12V
3.0A
NX301-U4F
±5V
45A
± 15V
8A/10A
± 15V
8A/10A
± 5V
3.0A
NX301-U4G
±5V
45A
± 15V
8A/10A
± 15V
8A/10A
± 24V
1.5A
NX301-U4H
±5V
45A
± 15V
8A/10A
± 15V
8A/10A
± 12V
3.0A
NX301-U3N
±5
45A
±5
8A
±12
8A
NX301-U4P
±5
45A
±12
8A
±15
8A
±12
3.0A
Note: Peak current ratings are for 10sec maximum. Total power not to exceed 300 watts.
Output Specifications
Parameter
Limits
Regulation
Line
± 0.03%
Load
±0.25%
Cross
±0.05%
Minimum Load
Output #1
3.0A
Auxiliary Outputs
0.1A
Hold-Up Time
Parameter
25mSec at Full Load
Conditions
Min
Voltage Adustment Range
PARD
Typ
Max
±5
20 MHz bandwidth
Units
%
1
% P-P
50
°C
70
°C
+85
°C
Temperature
Operating
0
Derates to half power
Storage
Temperature Coefficient (TC)
www.murata-ps.com
-20
After half hour warm-up
± 0.02
%/°C
Technical enquiries - email: [email protected], tel: +1 508 339 3000
Mechanical
TOP VIEW
0.040
1.95
8.50
0.25
COVER
0.55
1
TB2
3.90
4.85
1
J9
OUTPUT NO. 1
1
5V RETURN
9.00
TB1
5V
6-32 THD 4 PLC’S
Maximum depth of mounting
screws is 0.156 inches
NOTES:
All measurements are in inches
FAN MOUNTED ON COVER ADDS 1.30”.
COOLING: The NX301 is designed to operate with 30 CM airflow.
SHOCK AND VIBRATION: The NX301 meets the requirements of MIL STD-810D. (Vibration-Method 514.3 Procedure I; Shock-Method 516.3 Procedure I).
WEIGHT: Approximately 3 lbs.
Terminal Block 1
J9 Connector
Terminal Block 2
POS
FUNCTION
POS
FUNCTION
PIN
FUNCTION
1
AC Line
1
-V2
1
+ Sense
- Sense
2
AC Neutral
2
+V2
2
3
Ground
3
-V3
3
N/C
4
+V3
4
N/C
5
-V4
5
Start Up Sync.
+V4
6
Power Fail
7
Remote Inhibit
8
Current Share
9
Cntl Signal Rtn
6
J9 Connector
Molex No.
Connector
22-28-1090
Standard Options are shown, consult factory for other available options.
www.murata-ps.com