Contact Factory for Replacement Model 300 WATT AC/DC POWER SUPPLY .8 DESCRIPTION 4HE.8ISACOMPACTWATT0OWER&ACTOR#ORRECTED MULTIPLEOUTPUTPOWERSUPPLY!LLOUTPUTSAREFULLYISOLATED ANDREGULATED!CTIVECURRENTSHARINGCIRCUITRYTOGETHERWITH CONTROLFUNCTIONSANDALARMOPTIONSSIMPLIFIES.AND REDUNDANTAPPLICATIONS&ANANDDISKDRIVEAPPLICATIONSARE HANDLEDBYTHEPEAKCURRENTRATINGSOFTHEAUXILIARYOUTPUTS FEATURES Active Power Factor Correction Fully Isolated Outputs Low Profile: 9” x 4.85” x 2.00” One, Two, Three and Four Output Models N+1 Current Sharing FCC/VDE Class B EMI Filter Standard Optional Fan Mounted On Cover AGENCY APPROVALS www.murata-ps.com Technical enquiries - email: [email protected], tel: +1 508 339 3000 Input Specifications Parameter Operating Range Conditions Max Units 264 VAC 120VAC, cold start 35 APK 240VAC, cold start 70 APK 47-63 Hz Min Typ 90 Inrush Current Limiting Efficiency 120V 120V, full load 70 % 240V 240V, full load 75 % Power Factor Correction (PFC) 0.99 Meets IEC 1000-4-7/EN61000-3-2 (formerly IEC 555-2) Remote Sense Remote Sense is provided on Output #1 and will compensate for 0.7V of line drop. Remote Sense leads are protected against open, short and reversal. Remote On/Off The power supply is turned on with a TTL logic ‘1’ (or open) signal and turned off by a switch closure or TTL logic ‘0’ referenced to (-) sense terminal. Consult the factory for other options. Over Voltage Protection Output #1: 6.5V ± 0.5 VDC. The power supply will latch off until AC power is cycled. Over Current Protection Individual current limit on all outputs. Automatic recovery upon fault removal. Transient Response The peak output voltage excursion will not exceed 2% and will recover within 1% in 200 μsec for a 25% load step change. Power Fail Signal Upon AC input voltage removal, the power fail signal drops to logic zero at least 5msec before loss of DC output. On AC input turn-on, signal remains low until outputs are in regulation. Consult the factory for other options. N + 1 Load Share Output #1 has active load sharing circuitry. Units will load share within 1.5% of Maximum Rated Load. Over Temperature Protection Thermal switch turns off power supply if overheating occurs and automatically restarts. Safety UL Recognized: UL File Number E14675 (1950 & 1012) CSA Certified: CSA File Number LR 9070-154C (C22.2 No. 234-M90, Level 6) TUV License Number: R9576031 (EN60950) (IEC950) Cooling The unit is designed to operate with 30 CFM of airflow. Output Isolation All outputs are fully isolated. www.murata-ps.com Technical enquiries - email: [email protected], tel: +1 508 339 3000 Output Voltages and Maximum Rated Loads MODEL NUMBER OUTPUT #1 VOUT IMAX OUTPUT #2 VNOM IMAX/IPK OUTPUT #3 VNOM IMAX/IPK OUTPUT #4 VNOM IMAX NX301-U3A ±5V 45A ± 12V 8A/10A ± 12V 8A/10A - - NX301-U3B ±5V 45A ± 15V 8A/10A ± 15V 8A/10A - - NX301-U4C ±5V 45A ± 12V 8A/10A ± 12V 8A/10A ± 5V 3.0A NX301-U4D ±5V 45A ± 12V 8A/10A ± 12V 8A/10A ± 24V 1.5A NX301-U4E ±5V 45A ± 12V 8A/10A ± 12V 8A/10A ± 12V 3.0A NX301-U4F ±5V 45A ± 15V 8A/10A ± 15V 8A/10A ± 5V 3.0A NX301-U4G ±5V 45A ± 15V 8A/10A ± 15V 8A/10A ± 24V 1.5A NX301-U4H ±5V 45A ± 15V 8A/10A ± 15V 8A/10A ± 12V 3.0A NX301-U3N ±5 45A ±5 8A ±12 8A NX301-U4P ±5 45A ±12 8A ±15 8A ±12 3.0A Note: Peak current ratings are for 10sec maximum. Total power not to exceed 300 watts. Output Specifications Parameter Limits Regulation Line ± 0.03% Load ±0.25% Cross ±0.05% Minimum Load Output #1 3.0A Auxiliary Outputs 0.1A Hold-Up Time Parameter 25mSec at Full Load Conditions Min Voltage Adustment Range PARD Typ Max ±5 20 MHz bandwidth Units % 1 % P-P 50 °C 70 °C +85 °C Temperature Operating 0 Derates to half power Storage Temperature Coefficient (TC) www.murata-ps.com -20 After half hour warm-up ± 0.02 %/°C Technical enquiries - email: [email protected], tel: +1 508 339 3000 Mechanical TOP VIEW 0.040 1.95 8.50 0.25 COVER 0.55 1 TB2 3.90 4.85 1 J9 OUTPUT NO. 1 1 5V RETURN 9.00 TB1 5V 6-32 THD 4 PLC’S Maximum depth of mounting screws is 0.156 inches NOTES: All measurements are in inches FAN MOUNTED ON COVER ADDS 1.30”. COOLING: The NX301 is designed to operate with 30 CM airflow. SHOCK AND VIBRATION: The NX301 meets the requirements of MIL STD-810D. (Vibration-Method 514.3 Procedure I; Shock-Method 516.3 Procedure I). WEIGHT: Approximately 3 lbs. Terminal Block 1 J9 Connector Terminal Block 2 POS FUNCTION POS FUNCTION PIN FUNCTION 1 AC Line 1 -V2 1 + Sense - Sense 2 AC Neutral 2 +V2 2 3 Ground 3 -V3 3 N/C 4 +V3 4 N/C 5 -V4 5 Start Up Sync. +V4 6 Power Fail 7 Remote Inhibit 8 Current Share 9 Cntl Signal Rtn 6 J9 Connector Molex No. Connector 22-28-1090 Standard Options are shown, consult factory for other available options. www.murata-ps.com Technical enquiries - email: [email protected], tel: +1 508 339 3000