0RODUCT$ATA3HEET Contact Factory for Replacement Model 7!44 !#$#0/7%23500,9 08 $%3#2)04)/. 4HE08ISACOMPACTWATT0OWER&ACTOR#ORRECTED MULTIPLEOUTPUTPOWERSUPPLY!LLOUTPUTSAREFULLYISOLATED ANDREGULATED!CTIVECURRENTSHARINGCIRCUITRYTOGETHERWITH CONTROLFUNCTIONSANDALARMOPTIONSSIMPLIFIES.AND REDUNDANTAPPLICATIONS&ANANDDISKDRIVEAPPLICATIONSARE HANDLEDBYTHEPEAKCURRENTRATINGSOFTHEAUXILIARYOUTPUTS &%!452%3 !CTIVE0OWER&ACTOR#ORRECTION (IGH3URGE#URRENT!UXILIARY/UTPUTS &##6$%#LASS"%-)&ILTER &ULLY)SOLATEDAND2EGULATED/UTPUTS !'%.#9!002/6!,3 #OMPACT3IZEvXvXv /NE4WO4HREEAND&OUR/UTPUT-ODELS /PTIONAL#OVER7ITH&AN www.murata-ps.com Technical enquiries - email: [email protected], tel: +1 508 339 3000 Input Specifications Parameter Operating Range Conditions Min 47-63 Hz Typ 90 Max Units 264 VAC 30 APK 60 APK Inrush Current Limiting 120 VAC, cold start 240 VAC, cold start Efficiency Nominal line and full load 75 Power Factor Correction (PFC) % 0.99 Meets IEC 1000-4-7/EN61000-3-2 (formerly IEC 555-2) Remote Sense Remote Sense is provided on Output #1 and will compensate for 1.0V of line drop. Remote Sense leads are protected against open, short and reversal. Remote On/Off The power supply is turned on with a TTL logic ‘1’ (or open) signal and turned off by a switch closure or TTL logic ‘0’ referenced to (-) sense terminal. Consult the factory for other options. Over Voltage Protection Output #1: 6.5V, ±0.5 VDC The power supply will latch off until AC power is cycled. Over Current Protection Individual current limit on all outputs. Automatic recovery upon fault removal. Transient Response The peak output voltage excursion will not exceed 2% and will recover within 1% in 200 μsec for a 25% step load. Output Isolation All outputs are fully isolated. www.murata-ps.com Reverse Voltage Protection All outputs are protected to rated load current. Power Fail Signal Upon AC input voltage removal, the power fail signal drops to logic zero at least 10msec before loss of DC output. Upon AC input turn-on, signal remains low until outputs are in regulation. Consult the factory for other options. N+1 Load Share (PX403) Output #1 has active load sharing circuitry. Units will load share within 1% of Maximum Rated Load. Over Temperature Protection Thermal switch turns off power supply if overheating occurs and automatically restarts. Safety UL Recognized: UL File Number E14675 (1950 & 1012) CSA Certified: CSA File Number LR 9070-154C (C22.2 No9. 234-M90, Level 6) TUV License Number: R9576029 (EN60950) (IEC950) Cooling The unit is designed to operate with 40 CFM airflow. Technical enquiries - email: [email protected], tel: +1 508 339 3000 Output Voltages and Maximum Rated Loads OUTPUT #1 VOUT IMAX OUTPUT #2 VNOM IMAX/IPK OUTPUT #3 VNOM IMAX/IPK PX401/403-U3A ± 5V 50A ± 12V 12A/14A ± 12V 12A/14A - - PX401/403-U3B ± 5V 50A ± 15V 12A/14A ± 15V 12A/14A - - PX401/403-U4C ± 5V 50A ± 12V 10A/12A ± 12V 10A/12A ± 5V 3.0A PX401/403-U4D ± 5V 50A ± 12V 10A/12A ± 12V 10A/12A ± 24V 2.0A PX401/403-U4E ± 5V 50A ± 12V 10A/12A ± 12V 10A/12A ± 12V 3.0A PX401/403-U4F ± 5V 50A ± 15V 10A/12A ± 15V 10A/12A ± 5V 3.0A PX401/403-U4G ± 5V 50A ± 15V 10A/12A ± 15V 10A/12A ± 24V 2.0A PX401/403-U4H ± 5V 50A ± 12V 10A/12A ± 12V 10A/12A ± 5.2V 10.0A PX401/403-U4I ± 5V 50A ± 15V 10A ± 15V 10A ± 5.2V 10.0A PX401/403-U4J ± 5V 20A ± 17V 3A ± 17V 3A ± 24V 10.0A PX401/403-U4K ± 5V 25A ± 12V 10A ± 12V 10A ± 12V 4.0A PX401/403-U4L ± 5V 30A ± 12V 10A ± 12V 10A ± 5.2V 3.0A PX401/403-U4M ± 5V 30A ± 15V 12A ± 15V 12A ± 5.2V 10.0A PX401/403-U4N ± 5V 70A ± 12V 12A ± 12V 12A ± 3.3V 10.0A PX401/403-U4P ± 5V 30A ± 12V 10A ± 12V 12A ± 24V 3.0A PX401/403-U4R ± 5V 20A ± 15V 4A ± 15V 4A ± 24V 10.0A PX401/403-U4S ± 5V 20A ± 12V 8A ± 12V 3A ± 24V 10.0A MODEL NUMBER OUTPUT #4 VNOM IMAX Note: Peak current ratings are for 10sec maximum. Total power not to exceed 400 watts. Output Specifications Parameter Limits Regulation Line ± 0.1% Load ±0.5% Cross ±0.1% Minimum Load Output #1 Hold-Up Time Parameter 2.5A 30mSec at Full Load Conditions Min Voltage Adustment Range PARD 20 MHz bandwidth Typ Max Units ±5 % 0.5 % P-P Temperature Operating Storage Temperature Coefficient (TC) www.murata-ps.com After half hour warm-up 0 50 °C -20 +85 °C ± 0.02 %/°C Technical enquiries - email: [email protected], tel: +1 508 339 3000 Mechanical 0.700 0,040 COVER 2.148 8.500 TOP VIEW 0.550 3.900 4.850 1 2 3 4 5 6 TB2 J9 1 2 3 5V 10.000 TB1 5V Return Maximum depth of mounting screws is 0.156” NOTES: All measurements are in inches FAN MOUNTED ON COVER ADDS 1.30”. COOLING: The PX401/403 is designed to operate with 40 CFM airflow. SHOCK AND VIBRATION: The PX401/403 family meets the requirements of MIL STD-810D. D(Vibration-Method 514.3 Procedure I; Shock-Method 516.3 Proedure I). WEIGHT: Approximately 4 lbs. Connector Specifications Pin Specifications Terminal Block 1 Terminal Block 2 J9 Connector POS FUNCTION POS FUNCTION PIN FUNCTION 1 Ground 1 -V4 1 - Sense 2 AC Neutral 2 +V4 2 + Sense 3 AC Line 3 -V3 3 Current Share 4 +V3 4 Remote Inhibit 5 -V2 5 Power Fail 6 +V2 J9 Connector Molex No. Connector 22-28-1050 Model PX403 features Active Current Sharing Standard Options are shown, consult factory for other available options. www.murata-ps.com Technical enquiries - email: [email protected], tel: +1 508 339 3000